Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (2)
  • 1991  (2)
  • 78.55.Cr  (1)
  • Prostate-specific antigen  (1)
Material
Years
  • 1990-1994  (2)
Year
  • 1991  (2)
Keywords
  • 1
    ISSN: 1434-0879
    Keywords: Prostate cancer ; Tumor marker ; Prostate-specific antigen ; γ-Seminoprotein
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Prostate-specific antigen (PA) and γ-seminoprotein (γ-Sm) were compared by immunocytochemical, immunodiffusion and immunoblotting methods using rabbit anti-PA antibody and rabbit anti-γ-Sm antibody. Enzyme immunoassys (EIAs) were developed for measurements of PA and γ-Sm to determine a correlation between serum PA and γ-Sm levels in patients with prostate cancer. The patterns of localization and distribution of PA and γ-Sm were identical in prostate tissue sections, including benign and cancerous human prostacs. The immunodiffusion study showed that the antigens with which anti-PA antibody and anti-γ-Sm antibody reacted in seminal plasma and prostate tissue homogenates were identical to each other. In the immunoblotting study, anti-PA antibody and anti-γ-Sm antibody recognized a single antigen corresponding to a molecular weight of approximately 33,000 both in seminal plasma and prostate tissue homogenates. The EIAs developed in this study were sensitive, specific, and reproducible, and the correlation between serum PA and γ-Sm values determined by these EIAs was highly significant (r=0.99, P(0.001). These results indicated that PA and γ-Sm were immunologically identical and that serum PA and γ-Sm determined by immunoassays using anti-PA antibody and anti-γ-Sm antibody should be evaluated as identical tumor markers for serodiagnosis of prostate cancer.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-0630
    Keywords: 78.55.Cr ; 78.30.Gt ; 81.20.-n
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract Mg+ ions were implanted into highly pure InP grown by the liquid encapsulated Czochralski (LEC) method in which the Mg concentration [Mg] was varied between 1×1015 cm−3 and 3×1020 cm–3. Two annealing methods were used: furnace annealing (FA) up to 740° C and flash lamp annealing (rapid thermal annealing, RTA) up to 900° C. For characterization, photoluminescence (PL) spectra were measured between 2K and room temperature together with Raman scattering measurements at room temperature. An emission designated by g, which was attributed to a novel energy state of an isolated acceptor, was found to be produced for a rather low value of [Mg]. In addition, a broad emission denoted by [g−g], which was ascribed to acceptor-acceptor pairs, was observed below bound exciton emissions for moderate values of [Mg]. These features were quite similar to those previously observed in acceptor-doped GaAs when the background concentration of donors is extremely low. Two additional novel emissions located far below the band-to-acceptor emission were also obtained, and each showed a remarkable energy shift towards lower energy with increasing [Mg]. The binding energies of these emissions were estimated from the temperature dependence of PL spectra and the results suggest that they are complex-type radiative recombination centers, presumably donor-acceptor-type centers. A strong broad emission centered near the band-to-acceptor emission was observed for [Mg]=3×1020 cm−3. This observation indicates a formation of a new material between In, P and Mg, which was also attested by the appearance of a new TO-like Raman signal for [Mg] greater than 1×1019 cm−3. A substantial difference of PL and Raman spectra was revealed for the two annealing methods, suggesting that the annealing behaviour of ion-implanted InP should be investigated more extensively in order to establish reliable annealing procedures.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...