Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (2)
  • 1994  (2)
  • Embolisation  (1)
  • X-ray microanalysis  (1)
  • 1
    ISSN: 1432-2307
    Keywords: Mast cell ; Quick-freezing ; Compound 48/80 ; X-ray microanalysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract X-ray microanalysis was performed on rat mast cells prepared by quick-freezing, cryosectioning and freeze-drying (QF-FD) method, or quick-freezing and freeze-substitution (QF-FS) method. Peritoneal cells including mast cells were stimulated with compound 48/80 for 0, 10 or 30 s at 17° C, and the mast cells stimulated for 30 s started exocytosis. In X-ray spectra of the QF-FD specimen, mast cells stimulated for 10 s increased their levels of phosphorus, sodium and chlorine in the intergranular cytoplasm prior to exocytosis, and kept this increase until 30 s after stimulation. In the QF-FS specimen, where soluble elements were removed, peaks of phosphorus, sulphur and potassium could be detected as elements in X-ray spectra. Phosphorus increased and potassium decreased in intergranular cytoplasm of mast cells stimulated for 10 s, and these changes became more obvious after 30 s. However, supplemental increase of other cations such as sodium could not be detected in the QF-FS specimens.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1920
    Keywords: Arteriovenous malformations ; Embolisation ; Guide wire ; Minicatheter ; Progressive suppleness pursil catheter ; Superselective catheterisation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract For safe, more definitive embolisation of arteriovenous malformations, improved selectivity of the catheter is desirable. This report describes the advantage of the combined use of a progressive suppleness pursil catheter and a hydrophilic polymer-coated guide wire, together with precaution against complications. In 14 patients, 27 vessels were catheterised with this. Chemical embolisation using oestrogen alcohol and polyvinyl acetate was carried out only if sufficiencytly superselective catheterization was achieved with negative results on a provocation test. Chemical embolisation was successful in 25 vessels, but in three vessels catheterised very distally, it required much more time to withdraw the catheter because of the friction between it and the wall of the vessel.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...