Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 69 (1996), S. 4047-4049 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: We measured the effects of light soaking on the extended state electron mobility in intrinsic and n-type doped hydrogenated amorphous silicon samples. We obtained the temperature dependence of the mobility in the range 0–80 °C, using a recently proposed method [Dawson et al., Appl. Phys. Lett. 63, 955 (1993)]. We found a decrease of the mobility as the degree of light-induced degradation increased. We suggest that these changes in the extended state transport are caused by an enhancement in the magnitude of the potential fluctuations introduced by the extra created charged defects. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 69 (1996), S. 2599-2601 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: We have developed a technique to quantitatively image the magnetic field above a magnetic specimen using a modified magnetic force microscope (MFM). The technique depends on the nonlinear response of a magnetically soft MFM tip to the sample field and to an externally applied field, similar in principle to fluxgate magnetometry. We demonstrate the technique with high resolution, quantitative images of the magnetic field above a sample of longitudinal recording media. The magnetic field resolution is on the order of 1 Oe, with sub-100 nm spatial resolution comparable to standard MFM techniques. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 105 (1996), S. 2212-2222 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: Weak satellites in S1←S0 excitation spectra of natural-abundance pentacene in p-terphenyl due to position-specific 13C isotope shifts were observed. An assignment of these satellites to the various carbon positions is derived. The extremely narrow inhomogeneous linewidth allowed selective excitation of pentacene molecules with 13C in specific positions. Spectra of the magnetic-resonance transition between triplet sublevels of such ensembles, and of individual pentacene molecules showed position-specific 13C hyperfine broadening. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Entomologia experimentalis et applicata 80 (1996), S. 325-333 
    ISSN: 1570-7458
    Keywords: oviposition ; biological control ; predators ; mass rearing ; choice tests ; anthocorids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract A variety of natural and artificial substrates were tested for their suitability as oviposition sites for the predatory anthocorid bug Orius insidiosus. The bugs oviposited into models of beans constructed from Parafilm, but none of the eggs laid into these models hatched. In choice tests, beans stems were preferred to both bean pods and potato sprouts. Hatching rates at 100% r.h. were highest (59%) for bean pods and significantly lower for both potato sprouts (39%) and bean stems (29%). At 60% r.h., hatching rates for bean pods (39%), bean stems (34%) and potato sprouts (33%) were similar. At 30% r.h. hatching rates for all three substrates were less than 15%. The results suggest that bean stems can be used successfully as an alternative to bean pods for the mass rearing of these biological control agents.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Journal of insect behavior 9 (1996), S. 23-35 
    ISSN: 1572-8889
    Keywords: Reduviidae ; interspecific predation ; intraspecific predation ; nutrition ; kin recognition
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract Selected nutritional and developmental factors regulating the predatory behavior of first-instar spined assassin bugsSinea diadema (Fabricius) (Hemiptera: Reduviidae) were investigated. The longevity of unfed nymphs provided with free water, bean pod sections, or glucose solutions was not significantly greater than that of unfed nymphs which were not provided with a source of water. First-instarS. diadema that were provided with larvae ofEphestia kuehniella Zeller (Lepidoptera: Pyralidae) as prey began feeding 1.9 (±0.9) days after hatching. In contrast, first-instarS. diadema that were provided with conspecifics of the same age did not begin feeding until they were 3.9 (±0.9) days old. These results suggest that the potential nutritional benefits to be gained from feeding equal or outweigh the risk of attacking prey capable of effective self-defense only when nymphs have not fed for 4 days after hatching. Providing the nymphs with water or glucose solutions significantly delayed the onset of conspecific predation. Additional data are presented which demonstrate that first-instarS. diadema are not restrained from preying on siblings by kin recognition.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Journal of insect behavior 9 (1996), S. 37-45 
    ISSN: 1572-8889
    Keywords: predator-prey interactions ; Reduviidae ; hunger ; cannibalism
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract Fed and unfed first instars of the spined assassin bugSinea diadema were paired to evaluate the effects of food deprivation on their behaviour during encounters. Fed nymphs encountering starved 5-day-old nymphs retreated from 69% of the encounters after contacting the starved nymph. In contrast, starved nymphs initiated grappling during 30% of the encounters with fed nymphs and retreated significantly less often than the fed nymphs. When a single fed nymph was placed together with two unfed 3-day-old nymphs in a closed arena, the fed nymphs generally were not the first nymph cannibalized and were the final survivors in 67% of 24 replicates. These results are discussed in the context of the relative costs and benefits of escalating or retreating from encounters.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1434-3916
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We constructed a computer-assisted implantation device to compare different cementing techniques of stem implantation in total hip arthroplasty, thus avoiding any manual influence during implantation. We used an intramedullary plug in each case. Conventional cementing techniques, employing an additional lateral drain for the femoral canal or applying the cement by hand, did not lead to a satisfyingly reproducible quality of the cement mantle. With the vacuum cementing technique, in which an additional cannulated screw is inserted into the plug from the lateral side of the femur for the application of the vacuum, the cement mantle improved in quality, but there was still a relatively high number of bubbles incorporated in the cement. We think that, even under improved experimental circumstances, it is not always possible to place the cannulated screw correctly into the plug in order to achieve a satisfying drainage of the femoral canal with this procedure. The transprosthetic drainage system showed the best results due to the optimized position and working capacity of the drain.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Archives of orthopaedic and trauma surgery 115 (1996), S. 339-343 
    ISSN: 1434-3916
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We would like to introduce a new classification for heterotopic ossifications (HO) after total hip arthroplasty which also considers ossifications within the region of the surgical approach. Furthermore, we will point out the influence of the surgical approach on the rate of HO. We analyzed 75 cementless hip arthroplasties with consecutive HO in a prospective study. The operations were performed by three experienced orthopaedic surgeons using an identical stem and a standardized lateral approach. All patients followed an identical rehabilitation procedure. Clinical and radiological data were documented in a standardized way. We found a total of 40 HO. Only 24 could be exactly classified by the known methods. Our classification considers 3 regions and 4 grades and is relevant for all 40 HO. Electrocauterisation to dissect the muscles in the lateral approach reduced the rate of HO: overall 64.3% to 39.4%; clinically relevant ossifications were reduced to 3.0% from 16.7%. Our new classification considers all HO concerned with total hip arthroplasty, especially those localized in the intertrochanteric region. The rate of HO can be reduced by using electrocauterisation for muscle dissection in the lateral approach.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Archives of orthopaedic and trauma surgery 115 (1996), S. 149-152 
    ISSN: 1434-3916
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract For the treatment of infected joints, bones and soft tissues, either an instillation drainage therapy or the use of gentamicin-polymethyl-methacrylate (PMMA) chains (Septopal) in addition to surgical revision and systemically given antibiotics is currently in clinical use. We investigated 102 patients treated in our clinic by means of instillation drainage and compared the results with those obtained with gentamicin-PMMA chains by other authors. The overall long-term success with non-recurrence of the infection is nearly comparable (80% instillation drainage, 84% gentamicin-PMMA chains); however, with instillation drainage the duration of hospitalisation is significantly longer (mean 42.26 days vs 15.3 – 33 days). Additionally, there was a high rate of germ shifts with instillation drainage (33.3%) and a disappointing result in 20 infected endoprostheses (9 recurrences with 11 revisions). Regarding the intensive nursing care required and the necessary isolation from other patients, instillation drainage can only be recommended for the therapy of infected joints, bones and soft tissues if the results are better in comparison with gentamicin-PMMA chains. An improvement may be achieved with the closed instillation drainage system.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Infusionswärmung ; Durchflußwärmer ; Hypothermie ; Wärmeverluste ; Key words Body temperature ; Hypothermia ; Infusion ; Blood transfusion ; Equipment design
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Heat loses during surgery occur mainly to the environment and due to infusions and irrigations. Infusions given at room temperature account for a great deal of the total heat deficit during major operations, e.g., the infusion of 53 ml/kg 20° C fluid leads to a loss of 1° C in mean body temperature. Hence, heating i.v. fluids will add to the effect of other measures aimed at reducing heat loss to the environment. We investigated the efficacy of different warming methods for i.v. fluids in an experimental model by measuring the temperature at the end of the delivery line. Methods. The following in-line warmers were studied: Hotline HL-90 and System H-250/heat exchanger D-50 (Level 1 Technologies, Marshfield, USA), Astotherm IFT 260 (Stihler Elektronic GmbH, Stuttgart, Germany), RSLB 30 H Gamida (Productions Hospitalieres Francaises, Eaubonne, France), Bair Hugger 241/Modell 500 Prototype (Augustine Medical, Eden Prairie, USA). They were compared with prewarming infusions (39° C) only using the Clinitherm S (Labor Technik Barkey GmbH, Bielefeld, Germany) and prewarming with “active insulation” of the delivery line using the Autotherm/Autoline system (Labor Technik Barkey GmbH, Bielefeld, Germany). We investigated the influence of four variables on the efficacy of warming: (1) flow rate (50–15,000 ml/h); (2) ambient temperature (20° C and 25° C); (3) infusion bag temperature (6° C, 20° C, and 39° C); and (4) length of infusion system downstream from the heat exchanger. Fluid temperatures were measured using thermistors of 1 mm diameter (Modell YSI 520, Yellow Springs Instruments Co., Yellow Springs, USA) incorporated into 3-way stopcocks. Temperatures were recorded using Hellige temperature monitors (Hellige GmbH, Freiburg im Breisgau, Germany) and the signals were collected at 10 Hz through an AD converter and averaged over 1 min. Flows were calculated by timed collection into calibrated cylinders; 10 to 12 different flow rates were taken to define one temperature/flow plot. Effective warming was defined as a temperature 〉33° C at the end of the infusion line. Results. At high flow rates (〉2,500 ml/h) using 20° C fluids at 20° C ambient temperature, the H-250/D-50 system gave the highest temperatures throughout the range and showed effective warming from 1,300 ml/h on over the entire range tested (35° C at 17,000 ml/h) compared to the RSLB 30 H Gamida system (3,000–18,000 ml/h) (Fig. 2). This difference in performance was almost abolished with fluids at 6° C (Fig. 4). Similar efficacy could be reached by using prewarmed infusions that gave effective warming at 〉2,000 ml/h and reached 39° C at 13,000 ml/h. Prewarmed infusions could be used effectively down to 〉80 ml/h applying “active insulation” (Autotherm/Autoline) to the whole infusion system. The Hotline HL-90 (50–4,700 ml/h) appeared to be the most effective in-line warmer in the low (〈250 ml/h) and middle (250–2,500 ml/h) flow range, followed by the Astotherm IFT 260 (400–4,000 ml/h), but only if used with a length of 40 cm down-stream from the heat exchanger (Fig. 1). Increasing this distance to 145 cm markedly reduced its efficacy below the range of 2,000 ml/min (1,200–3,000 ml/h) (Fig. 5). The Bair Hugger 241 Prototype showed a narrow effective range (700–1,300 ml/h) that could be extended beyond 1,300 ml/h by the use of prewarmed infusions (Figs. 1 and 3). The performance for 6° C solutions and ambient temperatures of 25° C are given in Fig. 4 and Table 1. Conclusions. The importance of infusion warming increases with the amount of fluid given. In general, the infusion bag temperature only influenced the efficacy of in-line warmers within the high-flow range, challenging the performance of the heat exchanger. The length of uninsulated i.v. line downstream from the heat exchanger influenced the efficacy within the low- and middle-flow range, as did the room temperature. Prewarmed solutions can be infused very effectively within the high-flow range. This efficiency can be preserved down to the low-flow range by using “active insulation” of the infusion system. In-line warming is essential for emergency and rapid massive transfusions.
    Notes: Zusammenfassung Eine Hypothermie gehört zu den häufigsten Komplikationen in der perioperativen Phase. Eine ihrer Ursachen liegt in der Applikation unzureichend erwärmter Blut- und Infusionslösungen. Es wurde die Effektivität verschiedener Erwärmungsverfahren untersucht: 1) Vorwärmung von Infusionen (39° C) und 2) Verschiedene Durchflußwärmer (System H-250 ® /D-50 ® , RSLB 30 H Gamida ® , Hotline ® HL-90, Autotherm ® /Autoline ® , Astotherm ® IFT 260, Bair Hugger ® 241 Prototyp). Als Effektivitätsgrenze wurde eine patientennahe Infusionstemperatur von ≥33° C definiert. Variiert wurden a) Flußrate (50–15000 ml/h), b) Ausgangstemperatur der Infusion (6, 20 und 39° C), c) Länge des Infusionssystems nach dem Wärmetauscher und d) Umgebungstemperatur (20 und 25° C). Für eine Raum- und Infusionstemperatur von 20° C wurden folgende effektive Arbeitsbereiche gefunden: System H-250 ® /D-50 ® 1300- bis mindestens 17000 ml/min, RSLB 30 H Gamida ® 3000–18000 ml/min, Hotline ® HL-90 50–4700 ml/min, Astotherm ® IFT 260 Infusionssystemlänge 40 cm: 400–4000 ml/min, Infusionssystemlänge 145 cm: 1200–3000 ml/min, Bair Hugger ® 241 700–1300 ml/min, Autotherm ® /Autoline ® mit vorgewärmten Infusionen (39° C) 〉80 ml/min, vorgewärmte Infusionen (39° C) ohne „aktive Isolation“ 〉2000 ml/min. Für die getesteten Variablen gilt: Eine geringe Ausgangstemperatur der Infusion reduziert nur im hohen Flußbereich die Effektivität der Wärmer. Je niedriger Flußrate und Umgebungstemperatur sind und je länger das Infusionssystem nach dem Wärmetauscher ist, desto größer wird der Temperaturverlust auf dem Weg zum Patienten. Bis zu einem Infusionsfluß von 2000 ml/h ist eine effektive Infusionswärmung alleine durch Vorwärmung (39° C) generell nicht möglich.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...