Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (2)
  • 1997  (2)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European radiology 7 (1997), S. S256 
    ISSN: 1432-1084
    Keywords: Key words: MRI ; MR imagers ; Costs ; Cost containment
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. The total number of MR units available in Japan relative to the population is the highest in the world. The total number of MR units installed in 1996 was 2,663, equivalent to 24 per million population. The average charge per procedure in Japan is only one fifth of that in the United States (USA), approximately US$200 and US$950, respectively, suggesting that economic considerations in Japan may not take the highest priority. Despite the low costs, the utilisation (the number of patients examined each year or per week) of MR units in Japan is only about half that in the USA. As such, an increase in the number of MR units per se does not result in excessive health care costs.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1920
    Keywords: Key words Meningioma ; Schwannoma ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We studied 23 patients with meningiomas and 14 with schwannomas using dynamic spin-echo (TR/TE 200/15 ms) MRI. Histologically the meningiomas were classified according to the 1993 WHO classification. Serial images were obtained every 30 s for 210 s after rapid injection of gadopentetate dimeglumine (0.1 mmol/kg). The contrast-enhancement ratio (CER) was divided into three patterns; a sharp rise with a peak within 60 s (A), a relatively rapid increase with a peak between 60 and 210 s (B), a slow increase without a peak (C). The patterns were correlated with the histology of the tumors. The signal intensities of the tumours on T2-weighted images were also analyzed and correlated with the dynamic patterns. Meningiomas had more varied dynamic patterns than schwannomas. Almost half of the meningiomas showed pattern A, and one third pattern C. Of six meningothelial meningiomas showed pattern A; all schwannomas and fibrous meningiomas showed pattern C. Various patterns were observed in transitional meningiomas. Of the 8 meningiomas showing pattern C, only one gave high signal on T2-weighted images, and could not be differentiated from the schwannomas. Thus, one third of meningiomas could not be differentiated from schwannomas by the dynamic contrast enhancement alone. However, when this was combined with the signal intensity on T2-weighted images, most meningiomas could be differentiated from schwannomas.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...