Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-2277
    Keywords: Key words Vascular complications ; Pancreas-kidney transplant ; Thrombosis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Vascular complications remain a significant nonimmunologic source of pancreas allograft loss. From February 1993 through January 1998, we performed 98 simultaneous pancreas-kidney transplantations (SPK) using pancreatic exocrine bladder drainage in patients with type 1 insulin-dependent diabetes mellitus and end-stage renal disease. They originally received quadruple immunosuppression, and since May 1997 triple immunosuppression protocol (tacrolimus, mycophenolate mofetil, and steroids). The patients' mean age was 37 years (range 24–53 years), including 50 women and 48 men with a mean follow-up of 42 months. The overall rate of vascular complications was 6 % (5 patients). The vascular complications were as follows: late thrombosis of the Y with persistent pancreas allograft function (n = 1), rupture of a pseudoaneurysm of the superior mesenteric artery (PSMA) with an arteriovenous fistula (AVF) (n = 1), thrombosis of the splenic vein (SV) (n = 3), complete thrombosis of the superior mesenteric vein (SMV) and splenic vein (n = 1). The patient with PSMA underwent surgical correction of the AVF and PSMA with preservation of the allograft pancreas function. The other patient with late thrombosis of the Y-graft required no treatment. All 3 patients with SV thrombosis were systemically heparinized followed by oral anticoagulation. The patient with complete thrombosis required surgical thrombectomy of the SMV and SV followed by heparinization and oral anticoagulation. All 6 patients including the 4 with thrombosis had preservation of the pancreas function. Serial pancreas ultrasound showed resolution and improvement with recanalization of the splenic vein and superior mesenteric vein in those patients with thrombosis. We describe our vascular experience with salvage of the pancreatic allograft function. Surgery seems to be the best treatment option in the case of AVF or complete thrombosis of the allograft. Intravenous heparin followed by oral anticoagultion could be a conservative approach for SV thrombosis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-0743
    Keywords: dobutamine stress echocardiography ; myocardial scintigraphy ; SPET ; Sestamibi ; pharmacological stress testing ; coronary artery disease
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Background: Simultaneous dobutamine stress echocardiography (DSE) and99mTc-MIBI-SPET (DMS) for the evaluation of the presence and the extent of coronary artery disease (CAD) were assessed for a head to head comparison regarding the diagnostic accuracy of the two tests. Methods and Results: Forty-five consecutive patients (33 males and 12 females: 53±6.8 yr.) underwent exercise electrocardiography and simultaneous dobutamine stress echocardiography and MIBI-SPET imaging. Coronary angiography was performed in all patients (significant coronary stenosis 〉 50%). On the basis of the results of exercise electrocardiogram the pre-test probability for coronary artery disease (Diamond's algorithm) was low (45.6±12.7 %). The overall specificity, sensitivity and predictive accuracy of Echo-dobutamine stress test for diagnosis of the presence or absence of CAD were: specificity 82%, sensitivity 76%, diagnostic accuracy 80%, positive predictive value 90%, negative predictive value 40%. The overall specificity, sensitivity and predictive accuracy of MIBI-SPET-dobutamine test for diagnosis of the presence or absence of CAD were: specificity 86%, sensitivity 87%, diagnostic accuracy 84%, positive predictive value 97%, negative predictive value 54%. MIBI-SPET-dobutamine test showed a significantly higher sensitivity in comparison with ECHO-dobutamine test (P〈0.05). Conclusion: Both noninvasive methods for the detection of CAD showed a good diagnostic accuracy. Nevertheless the SPET model showed an higher sensitivity in comparison with DSE model, essentially in the presence of a lower extent of CAD and during submaximal test.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...