Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2000-2004  (8)
  • 1995-1999  (59)
  • 1960-1964  (5)
  • 1950-1954  (1)
  • 1925-1929  (3)
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 1054-1056 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A volume source, based on the high efficiency ion source (HIEFS), is being developed for D+ production in steady state operation. The source will be optimized for the extraction of atomic deuterium ions with high current densities. It was found that a maximum deuterium ion beam current density of 210 mA/cm2 can be achieved with a D+ fraction above 90%. At an extraction voltage of 35 kV and with an aperture radius of 4 mm, the source delivers 61 mA D+. After a description of the source and the experimental setup, the results of detailed studies of the beam composition in dependence of the plasma parameters are presented. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 1249-1251 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Multicusp ion sources are used for various applications. Presently, the implementation of this type of ion source is planned for the development of an ion beam lithography machine, which will be used for the projection of sub-0.2 μm patterns onto a wafer substrate. Since, for this application, a very good beam quality and a small ion energy spread are required, emittance measurements have been performed on a multicusp ion source for various source conditions. It is shown that the installation of proper capacitors between the extraction electrodes is necessary to avoid rf pickup, which otherwise leads to a distortion of the beam emittance. The influence of the magnetic filter field on the beam emittance has been investigated, and the beam emittance of a dc filament-discharge plasma has also been compared to that of a rf-generated plasma. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 69 (1998), S. 1012-1014 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: For the European spallation source, a volume source based on the high efficiency source is being developed. The source will be optimized to produce high current densities in pulsed operation. A pulse generator delivering 1–1.5 ms pulses was installed. Furthermore, cesium was supplied to the plasma generator from an external oven. The cesium injection was optimized for a low e/H− ratio and a high current. We obtained a current density of 70 mA/cm2. This way, with an aperture radius of 4.25 mm, an H− current of 40 mA was extracted at an extraction voltage of 22 kV. After a description of the source and the experimental setup, measurements of the beam current density and the e/H− ratio will be presented in this article. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 71 (2000), S. 836-838 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: For the International Fusion Materials Irradiation Facility (IFMIF) scenario, a 140 mA deuterium beam in continuous wave (cw) mode with an atomic yield of above 85% is required. The normalized root-mean-square emittance should be less than 0.2 π mm mrad at the entrance of a RFQ. As part of a conceptual design for IFMIF, a new ion source has been developed and is tested at the Institut für Angewandte Physik in Frankfurt. The ion source is of the volume type with a tungsten cathode driving the discharge. Both cw and pulsed mode are possible and were studied. First experiments were carried out with deuterium. 80 mA deuterons with a D+ fraction of above 90% were extracted [A. Maser et al., Rev. Sci. Instrum. 67, 1054 (1996)]. In order to avoid neutron generation by the d–d reaction, hydrogen was used instead of deuterium later on. As far as the ion source and plasma production processes are concerned, the use of hydrogen instead of deuterium is equivalent because of their similar atomic shells. Recently, a 200 mA proton beam at 55 kV was extracted in cw mode (according to Child–Langmuir, 200 mA H+ corresponds to 140 mA D+) with a H+ fraction of 93%. This article will give a detailed description of the ion source and the essential experimental results. Especially, the influence of important physical parameters (such as discharge current and strength of the filter field) on the H+ fraction was studied. By using different kinds of auxiliary gases, the influence on the H+ fraction and the noise level were investigated, too. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 1039-1041 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A new version of the high efficiency source is being developed for the European Spallation Source. The goal of these experiments is to produce a nearly pure H− ion beam with a low electron to H− ratio and high current (70 mA). To achieve this, the discharge chamber is divided into two parts of different plasma parameters by means of a filter magnetic field. Furthermore, the plasma chamber is aligned unsymmetrically with respect to the z axis of the extractor. We obtained a current density of 10 mA/cm2 for an arc power as small as 1 kW. In preliminary experiments, a beam of 10 mA was extracted at an extraction voltage of 8 kV (1.8% impurities). Measurements of the beam current density, electron to H− ratio, and the ion composition for a wide range of discharge conditions will be presented in this article. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 69 (1998), S. 1066-1068 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A volume source based on the high efficiency source is being developed for heavy ion production. Bismuth was chosen for exemplifying investigations because of its low melting point. The ion source is driven by an arc discharge ionizing bismuth atoms which are evaporated from an oven inside the source chamber. It has been optimized to produce a beam with a fraction of singly ionized bismuth above 92%. A multiaperture extraction system was built consisting of seven holes with a radius of 3 mm each. For that system, the perveance limit was achieved at a beam current of 70 mA and an extraction voltage of 27.5 kV. The corresponding emission current density amounts to 35 mA/cm2. This value was obtained for an arc power of only 280 W. Furthermore, the emittance of a beam extracted from the multiaperture extraction system has been determined with a high power emittance scanner. It amounts to 0.27π mm mrad (80%, normalized, 4 rms). In this case, the emittance of a single beam is 0.017π mm mrad. This article will give a detailed description of both the source and the experimental setup. In addition, various dependencies between the plasma parameters and the beam composition are presented. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 71 (1997), S. 482-484 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The photoluminescence of CuInS2 thin films and solar cells is investigated as a function of postdeposition treatments for different temperatures and excitation intensities. Annealing in hydrogen atmosphere causes an increase of PL intensity at 1.445 eV by more than a factor of 100, while subsequent annealing in oxygen or air ambient passivates this transition, which is ascribed to a donor-acceptor pair recombination between a sulphur vacancy and a copper vacancy. A defect mechanism is suggested that assumes the passivation of sulphur vacancies by oxygen in grain surfaces which can be activated by hydrogen annealing. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 69 (1996), S. 3746-3748 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: A new method to prepare bicrystals with well defined planar interfaces in YBa2Cu3Ox (Y123) has been developed. The bicrystal misorientation is controlled by dual seeding using Nd1+xBa2−xCu3Oy single crystals. The grain boundary plane orientation is influenced by the positioning of the seeds and by control of the temperature gradient. The macro-, meso-, and microscopic planarity of the grain boundaries has been established by optical and electron microscopy. In addition, a difference in critical current density between the low (≤10°) and the high (≥20°) misorientation angle regime of nearly two orders of magnitude has been established in a series of [001]-tilt grain boundaries. Thus, this type of grain boundary may allow a less ambiguous interpretation of the relationship between microstructure and transport properties than is possible from bicrystal thin film boundaries by eliminating the potential variations in properties associated with a varying grain boundary plane. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    British journal of dermatology 151 (2004), S. 0 
    ISSN: 1365-2133
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    British journal of dermatology 133 (1995), S. 0 
    ISSN: 1365-2133
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: A 28-year-old man with Wiskott—Aldrich syndrome presonied with ulcerative-proliferative lesions on his face from which herpes simplex type 1 (HSV-1) was isolated. He was initially treated with 10 mg/kg of acyclovir (Zovirax®) intravenously every 8h, but his skin lesions worsened. Clinical resistance to acyclovir was suspected, and therapy with this drug was intensified. The dosage of acyclovir was increased to 45 mg/kg, administered by continuous infusion, and the lesions subsequently resolved. The strain of HSV recovered from the patient showed acyclovir-resistance in vitro, using the colorimetric method with neutral red.Herpes simplex virus resistance to acyclovir is rare. It is more common in immunocompromised patients if subtherapeutic doses are administered in the treatment of chronic persistent forms of infection. Whenever clinical resistance to acyclovir is suspected, the dosage should be increased to 2 mg/kg per h administered via an infusion pump. If no improvement is observed in the patient's condition with this regimen, a phosphorylated medication whose mechanism of action is not dependent on viral thymidine kinase, such as foscarnet (phosphonoformic acid), should be substituted.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...