Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2000-2004  (8)
  • 1985-1989  (30)
  • 1975-1979  (8)
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 60 (1989), S. 2631-2634 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A new detection scheme for Fourier transform-ion cyclotron resonance (FT-ICR) studies is proposed and initial experimental results are presented. While in conventional FT-ICR, the difference of the transient signals from two opposite electrodes is recorded and Fourier transformed, it is also possible to use the sum of these signals. In this way resonances are observed at the harmonic of the reduced cyclotron frequency 2 ν+ as well as ν+−ν− and ν++ν−, the later being important for accurate mass measurements. The experiments were performed with a Penning trap in an electromagnet.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 272 (1975), S. 369-374 
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Neutron rich205Hg (T 1/2=5.2 min) was produced and on-line mass separated at the ISOLDE facility at CERN. The polarization achieved by optical pumping via the atomic line (6s 21 S 0↔6s6p 3 P 1,λ=2 537Å) was monitored by theβ decay asymmetry. Hyperfine structure and isotopic shift of the205Hg absorption line was determined by Zeeman scanning. In addition a magnetic resonance was performed on the polarized205Hg nuclei in the atomic ground state. The results are: $$I(^{205} Hg) = \tfrac{1}{2}$$ (confirmed);μ I (205Hg)=0.5915 (1)μ N (uncorrected for diamagnetism); isotopic shiftδv204/205=v(205Hg)-v(204Hg)=−1.8 (1) GHz.μ I and IS are discussed briefly in the frame of current literature.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract An optical pumping apparatus has been attached to the reconstructed ISOLDE on-line mass separator at CERN in order to obtain nuclear data of isotopes far fromβ stability. As first results the spins of76Rb (T 1/2=36.8 s) and119Cs (T 1/2=37.7 s) have been determined byβ radiation detected optical pumping (β-RADOP) to beI=1 andI=9/2 respectively.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 276 (1976), S. 187-202 
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The extension of the Nuclear Radiation Detected Optical Pumping method to mass-separated samples of isotopes far off stability is presented for a series of light Hg isotopes produced at the ISOLDE facility at CERN. The isotope under investigation is transferred by an automatic transfer system into the optical pumping apparatus. Zeeman scanning of an isotopically pure Hg spectral lamp is used to reach energetic coincidence with the hyperfine structure components of the 6s 2 1 S 06s6p 3P1,λ=2,537 Å resonance line of the investigated isotope and the Hg lamp. The orientation built up by optical pumping is monitored via the asymmetry or anisotropy of the nuclear radiation. Nuclear spins, magnetic moments, electric quadrupole moments and the isotope shifts are obtained for181Hg-191Hg using theβ asymmetry as detector. The extension of the method using theγ anisotropy is discussed and test measurements on193Hg are presented. This paper describes the experimental procedure, results, and discussion are given in a following publication.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 276 (1976), S. 203-217 
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The hyperfine structure splitting and the isotope shift in the (6 s2 1S0 - 6s 6p3P1,λ=2,537 Å) line of very neutron deficient Hg isotopes were determined by the β radiation detected optical pumping method (β-RADOP). In addition, nuclear magnetic resonance was observed in the atomic ground state. The results are Mean-square nuclear charge radii are calculated. Interpreting the sudden change of nuclear radius between187Hg and185Hg δ〈r2〉187,185=0.42(5)fm2 as oblate-prolate shape transition, one obtains δ〈β2〉 =0.054(5).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 321 (1985), S. 537-547 
    ISSN: 1434-601X
    Keywords: 21.10.-k ; 27.80+w ; 31.30.Gs
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The isotope shift between197Au (stable) and the radioactive Au isotopes190Au,191Au,192Au and193Au were determined by resonance fluorescence spectroscopy in the 6s 2 S 1/2–6p 2 P 1/2.λ=267.6nm line. The unstable Au isotopes were produced at the ISOLDE mass separator at CERN. The nuclei were investigated semi on-line in a resonance vessel, heated to 1,400°C. The results areδν 190,197=−11.12(39) GHz,δν 191,197=−9.67(12) GHz,δν 192,197=−8.32(15) GHz,δν 193,197=−6.29(11) GHz, corresponding to a change of the mean-square charge radius byδ〈r 2〉190,197 =0.261(12) fm2,δ〈r 2〉191,197=0.227(5) fm2,δ〈r 2〉192,197=0.195(5) fm2,δ〈r 2〉193,197 =0.148(4) fm2.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1432-0649
    Keywords: 32 ; 42.60 ; 07.65
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Laser photoionization has been used to detect trace amounts of plutonium. A high sensitivity and selectivity has been achieved by applying three-step excitation and ionization of the plutonium atoms with high pulse-repetition rates and additional mass determination by time-of-flight measurements. A laser system was developed which consists of a copper vapor laser pumping three dye lasers simultaneously. Samples containing between 1010 and 1012 atoms of239Pu on Re filaments were measured yielding strong resonance signals with maximum ion count rates of several kHz at a vanishingly low background. A detection efficiency of 10−7 was determined allowing the detection of about 108 plutonium atoms in a sample.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 38 (1985), S. 65-70 
    ISSN: 1432-0649
    Keywords: 42.80 ; 32.80F ; 32.80H
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Resonance ionization mass spectrometry (RIMS) has been tested for the isotope-selective determination of trace amounts of plutonium. An atomic beam is formed by evaporating plutonium atoms from a rhenium-filament heated to 1800 °C. The radiation of a pulsed dye laser excites the atoms in a two-photon process (λ=595.2 nm) followed by photoionization of the excited atoms. Mass selectivity is obtained by use of a time-of-flight spectrometer. A resonant signal of239Pu was measured with 1013 atoms deposited on the filament.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1432-0630
    Keywords: 07.65.Eh ; 32.70.Fw ; 32.80.Dz
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract Resonance ionization mass spectroscopy (RIMS) and pulsed-laser induced desorption (PLID) have been combined for ultrasensitive detection and spectroscopy of very small samples of refractive elements. The method has been tested and applied to laser spectroscopy of 5×109 atoms (1.5 pg) of195Au (T 1/2= 183d) implanted at the ISOLDE online mass separator with 60 keV into graphite. A pulsed thermal atomic beam was formed by laser desorption with a 10 ns Nd∶Yag laser pulse. Subsequently the atoms were photoionized in a three-colour, three-step resonant excitation to an autoionizing state. The selectivity was enhanced by a time-of-flight measurement of the photo ions. In resonance, one ion was detected per 105 atoms implanted resulting in a gain in detection efficiency by three orders of magnitude in comparison to the use of a continuous atomic beam. In the course of the experiments several unknown autoionizing states were found, and the lifetime of the 6d 2 D 3/2 state of gold was determined to beτ=10.7(6) ns.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1432-1459
    Keywords: Lumbar cerebrospinal fluid ; Individual proteins ; Total protein ; Tight junction pores ; Barrier transport
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Specific “reference areas” were derived from relationships between the proteins prealbumin, albumin, alpha1-acid glycoprotein, alpha2-macroglobulin, total transferrin, IgG, IgA, IgM, and the corresponding total protein in normal lumbar CSF samples. The procedure for calculating the boundary lines of these reference areas was carried out on the basis of double standard deviations in subgroups with total protein differences of 50 ml/l within the whole range of 150–400 ml/l CSF. The resulting biochemical data, hydrodynamic radii of the individual proteins investigated, and van Deurs' and Koehler's morphological findings on the existence of pores in the barrier-forming tight junctions of the choroid plexus epithelium could be surprisingly well correlated with one another, although these morphological findings were obtained in choroid plexus of the rat brain. The correlation allowed the conclusion that proteins undergo ultrafiltration via a pattern of tight junction pores with various diameters. However, the molecular mechanism seems to include an additional facilitating component.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...