Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2000-2004  (2)
  • Micron-sized, monodispersed particle  (1)
  • cyclophosphamide  (1)
  • 1
    ISSN: 1569-8041
    Keywords: cyclophosphamide ; dose intensity ; doxorubicin
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Background:CHOP is accepted as the gold standard for first linechemotherapy of aggressive non-Hodgkin's lymphoma (NHL). A dose-escalationstudy of CHOP was conducted to determine the maximal tolerated dose (MTD) andtoxicity profile of CHOP at three-week intervals with or without prophylacticrecombinant human granulocyte colony-stimulating factor (rHuG-CSF) in patientswith aggressive NHL. Patients and methods:The doses of drugs were escalated from 50mg/m2 to 70 mg/m2 for doxorubicin and from 750mg/m2 to 2250 mg/m2 for cyclophosphamide, withconventional doses of vincristine and oral prednisolone. After the MTD wasdetermined without rHuG-CSF, dose escalation was conducted with prophylacticrHuG-CSF. Results:Thirty-three patients with NHL were enrolled into thestudy. The MTD without prophylactic rHuG-CSF was 70 mg/m2 ofdoxorubicin and 1250 mg/m2 of cyclophosphamide, with neutropeniaas a dose-limiting toxicity. The MTD with prophylactic rHuG-CSF was 70mg/m2 of doxorubicin and 2250 mg/m2 of cyclophosphamide.The overall response rate was 100% (76% complete response and24% partial response). Progression-free survival and overall survivalat five years were 45% and 66%, respectively. Conclusions:Significant dose escalation of doxorubicin andcyclophosphamide was feasible with prophylactic rHuG-CSF. The efficacy ofdose-escalated CHOP should be compared with that of standard CHOP.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1435-1536
    Keywords: Key words Anomalous shape ; Micron-sized, monodispersed particle ; Solvent
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract  About 2-μm-sized polystyrene (PS) particles having uneven surfaces were prepared by a posttreatment in which toluene-swollen PS particles were thrown into a methanol bath to release toluene therefrom rapidly. The posttreatment was named the “solvent-absorbing/releasing method”. The PS particle had large dents at the surface. The size of the dents was changed by the conditions of the posttreatment.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...