    Description / Table of Contents: In a prospective, nonrandomized study conducted between February 1997 and September 1998, 29 displaced fractures of the distal femur were stabilized with an angularly stable interlocking plate system (less invasive stabilization system, or LISS) designed for minimally invasive placement. The LISS System consists of an anatomically configured plate contoured to fit percutaneously onto the lateral femoral condyles with monocortical screws which anchor into the plate , thus building an angularly stable construct. Using the AO fracture classification system, 33 group C3 fractures and 32 C2 fractures with intra-articular displacement were fixated via a transarticular approach with a lateral parapatellar arthrotomy of the knee joint and percutaneous placement of the shaft screws, while 33 group A fractures and 32 C2 and B1 fractures with no intra-articular dislocation were treated via a lateral stab incision and placement of the LISS laterally on the femoral shaft under the vastus lateralis muscle. Twenty-nine fracture cases were included in the follow-up studies. The average patient age was 54 years (range 20–92) and mean duration of follow-up was 6 months (range 1.5–16). The mean injury severity score (ISS) was 14.1 (range 9–27). Twenty-six fractures were located at the distal segment of the femur (localization 33) and further subdivided into 13 group C3, four group C2, eight type A fractures, and one type B fracture. An additional three fractures were located at the distal shaft (localization 32) and classified as subgroup B1.3. Eight fractures were open (5 type I, 2 type II, 1 type IIIB3). Mean operative time was 131 minutes (range 40–¶300). Mean image intensifier time was 142 seconds (range 31–402). Postoperative complications included one case with heterotopic ossification (HO) limiting knee motion, one of deep venal thrombosis with pulmonary embolism, and three cases of deep infection (one type IIIB open, one arterial injury, and one type II open). Implant-related complications included two cases of screw pullout in the proximal plate during the first 2 months postinjury. These cases were treated by screw exchange. In a 37-year-old female with an increased antetorsion angle of 32° (internal rotation deformity) in both femurs postoperatively, rotational correction was performed. Length of time to fracture healing averaged 3.1 months (range 2.5–4.5) in 23 cases. Length of time to full weight-bearing averaged 3 months (range 1.5–5). At the latest review of 15 cases with an average of 3 months’ follow-up, knee flexion averaged 121° (min. 20°, max. 140°). Thirteen cases displayed knee flexion of less than 120°, three of which had less than 90°. At follow-up, an extension lag of 10° was noted in two cases. The Lysholm score could be applied to nine patients and showed a mean of 67.5 points (range 48–92), and the Neer scores averaged 69.8 points (range 49–88) (one failure, three unsatisfactory, four satisfactory, and one excellent). The remaining cases were still undergoing follow-up evaluation at the time of writing. The correct use of LISS for distal femoral fractures leads to uneventful bony healing without the additional morbidity of bone grafts. However, due to demanding surgical technique in this region, special care must be taken to restore correct axial alignment.
    Notes: In einer prospektiven, nicht randomisierten Studie wurden zwischen Februar 1997 und September 1998 29 frische distale Femurfrakturen mit dem winkelstabilen, minimalinvasiv eingebrachten System LISS (less invasive stabilization system) versorgt. Das Prinzip des LISS ist ein perkutan eingebrachtes Implantat, das anatomisch nach dem rechten und linken lateralen Femurkondylus geformt ist. LISS wird mit winkelstabilen, monokortikalen Schrauben verankert. In dieser Studie wurden 33C3- und 33C2-Frakturen mit intraartikulärer Dislokation über einen transartikulären Zugang mit lateraler parapatellarer Arthrotomie versorgt, während bei den 33A-Frakturen, 33C2- und 32B1-Frakturen ohne intraartikuläre Dislokation ein lateraler Zugang gewählt wurde. In die Nachuntersuchung wurden 29 Frakturen eingeschlossen. Das Durchschnittsalter der Patienten war 54 Jahre (20–92 Jahre). Die durchschnittliche Nachuntersuchungszeit betrug 6 Monate (1,5–16 Monate) und der durchschnittliche ISS 14,1 (9–27). Offen waren 8 Frakturen (5mal Typ I, 2mal Typ II, 1mal Typ IIIB nach Gustilo). Die durchschnittliche Operationszeit lag bei 131 min (40–300 min). Die durchschnittliche Bildwandlerzeit betrug 142 s (31–402 s). Postoperativ kam es in 1 Fall zu heterotopen Ossifikationen mit Einschränkung der Kniegelenkbeweglichkeit, in 1 Fall zu einer tiefen Beinvenenthrombose mit Lungenembolie und in 3 Fällen zu tiefen Infekten, davon 2mal als Folge offener Frakturen. In 2 Fällen kam es zu Schraubenausrissen im proximalen Plattenbereich innerhalb der ersten 2 Monate. In 1 Fall war eine Rotationsdifferenz beider Femora von 32° zu sehen. Die Zeit bis zur knöchernen Durchbauung betrug durchschnittlich 3,1 Monate (2,5–4,5 Monate), die Zeit bis zur Vollbelastung 3 Monate (1,5–5 Monate). Die Kniegelenkbeweglichkeit war in 15 Fällen, mit einer Nachuntersuchungszeit von mehr als 3 Monaten, 121° (Minimum 20°, Maximum 140°). Der Lysholm-Score konnte für 9 Patienten ermittelt werden und ergab im Durchschnitt 67,5 Punkte (48–92 Punkte), der Neer-Score 69,8 Punkte (49–88 Punkte). Die Anwendung des LISS ermöglicht eine komplikationslose Ausheilung ohne Notwendigkeit der Knochentransplantation. Besonderes Augenmerk muß auf eine achsengerechte Reposition gelegt werden, da diese am distalen Femur schwierig ist.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Der Unfallchirurg 101 (1998), S. 296-298 
    ISSN: 1433-044X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Die Teilnehmer des “International AOI-SICOT Travelling Fellowship 1997” wurden von der Arbeitsgemeinschaft für Osteosynthesefragen (AOI), Davos und Societé International Chirurgienne et Traumatologie (SICOT) ausgewählt. Dr. Raul Barrios, New Orleans, USA, Dr. Carlos Rodriguez-Merchan, Madrid, Spanien und Professor Viktor Remizov, Chisinau, Moldova mit Prof. Dr. Christian Krettek, Medizinische Hochschule Hannover als Senior Travelling Fellow, besuchten vom 11. bis 31. Mai 1997 wichtige Trauma- und Forschungszentren in Bangkok, Singapur, Los Angeles, Birmingham/Alabama, Hannover, Zürich und Davos.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1433-044X
    Keywords: Key words Foreign-body reactions • Biocompatibility • Biodegradable implants • Classification • ; Osteolysis ; Schlüsselwörter Fremdkörperreaktionen • Biokompatibilität • Biodegradierbare Implantate • Klassifikation • Osteolysen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Biodegradierbare Implantate finden zunehmend Einsatz in Unfallchirurgie und Orthopädie. Die Anzahl der erhältlichen Implantate und der dabei eingesetzten verschiedenen Polymere nimmt ständig zu, wobei die Biokompatibilität problematisch bleibt. Diese wird von einer Vielzahl verschiedener Faktoren beeinflußt. Lokale Fremdkörperreaktionen können bei der Verwendung biodegradierbarer Implantate auftreten und müssen klinisch dokumentiert werden. Um eine Vergleichsmöglichkeit verschiedener Implantate zu ermöglichen, ist ein standardisiertes Instrument zur Klassifizierung solcher Fremdkörperreaktionen erforderlich. Basierend auf unseren klinischen und experimentellen Erfahrungen wurde ein Klassifikationssystem entwickelt, das eine systematische Dokumentation gewährleistet. Hierzu werden Fremdkörperreaktionen in Osteolysen (O-0 bis O-4), extraartikuläre (EA-0 bis EA-4) und intraartikuläre (IA-0 bis IA-4) Weichteilreaktionen unterteilt.
    Notes: Summary Biodegradable implants are increasingly used in orthopedic and trauma surgery. Many different implants consisting of different biodegradable polymers are currently available. Different factors contribute to the biocompatibility of these implants, and local foreign-body reactions remain a matter of concern. Therefore, it is mandatory to document and compare the tissue reactions caused by various biodegradable implants in experimental or clinical studies. We have developed a standardized system of classification based on our previous experimental and clinical observations. Foreign-body reactions are differentiated into osteolyses (O-0 to O-4), extra-articular (EA-0 to EA-4) and intra-articular (IA-0 to IA-4) soft-tissue reactions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Der Unfallchirurg 99 (1996), S. 616-627 
    ISSN: 1433-044X
    Keywords: Schlüsselwörter: Komplexes Knietrauma ; Distale Femurfraktur ; Proximale Tibiafraktur ; Kniegelenkluxation ; Key words: Complex knee injury ; Supracondylar femoral fracture ; Tibia plateau fracture ; Knee dislocation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1433-044X
    Keywords: Schlüsselwörter: Zielgerät zur distalen Verriegelung ; Unaufgebohrter Tibianagel ; Implantationsbedingte Nagelverformung ; Röntgenmorphometrische Untersuchung ; Key words: Aiming device for distal locking ; Unslotted tibial nail ; Implant deformation ; Radiographic ; Morphometric investigation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: n = 10; diameter 9 mm, n = 10) were inserted in paired human cadaver tibiae. The results showed lateral translations of –4.5±3.5 mm (mean and standard deviation, range 14.3 mm) and dorsal translations of –7.8±5.8 mm (mean and standard deviation, range 19.2 mm). Rotational deformations around the longitudinal axis of the nail were 0.3±0.7° (mean and standard deviation, range 2.4°). The results showed, that a simple aiming arm, mounted on the proximal nail end, alone or even in combination with a large working channel (e.g. 10 mm in diameter), was not adequate to the aiming process. A radiographic-morphometric analysis was subsequently performed in 40 tibiae after experimental (n = 20) or clinical (n = 20) implantation of nails 8 mm and 9 mm in diameter. These measurements showed a relatively constant distance between the upper distal transverse hole and the anterior aspect of the tibia (average 12.3 mm and only a narrow range (7.6 mm). These data were the basis for the development of an aiming technique that exploits the relatively constant distance between the distal nail hole and the anterior aspect of the tibia. This aiming device is set at a distance of 12.3 mm from the anterior cortex, and the fine tuning is finally resolved by the use of a `working channel' 10 mm in diameter.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1433-0385
    Keywords: Key words: Interlocking nail ; Tibia ; Distal interlocking ; Distal aiming device ; Free-hand technique ; Radiolucent drill. ; Schlüsselwörter: Verriegelungsnagel ; Tibia ; distale Verriegelung ; röntgenstrahlenunabhängiges ; distales Zielgerät ; Freihandtechnik ; strahlentransparentes Winkelgetriebe
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung. Seit kurzem stehen röntgendurchleuchtungsunabhängige, mechanische Zielsysteme für die distale Verriegelung von ungeschlitzten Tibiamarknägeln zur Verfügung, die die insertionsbedingte Nageldeformation kompensieren. Vergleichende Untersuchungen über Vor- und Nachteile dieser Systeme sind bisher noch nicht durchgeführt worden. Die vorliegende Studie untersuchte Operationsdauer, Länge der Durchleuchtungszeit und Präzision der Schraubenplazierung mit einem strahlenunabhängigen, mechanischen Zielsystem und einer Freihandtechnik (strahlentransparentes Winkelgetriebe). Von einem mit beiden Techniken unerfahrenen Chirurgen wurden am Frakturmodell der Tibia (Schrägosteotomie) an humanen Ganzkörperpräparaten im Rechts-Links-Vergleich Unterschenkelmarknagelungen mit statischer Verriegelung durchgeführt. Für das distale Zielgerät bzw. für die Freihandtechnik betrug die Gesamtoperationszeit 25,4 ± 11,3 vs. 30,9 ± 14,3 min (p = 0,029), die distale Verriegelungszeit 16,7 ± 8,6 vs. 21,9 ± 10,5 min (p = 0,004), die gesamte Durchleuchtungszeit 9 ± 5 vs. 93 ± 34 s (p 〈 0,0001), die Durchleuchtungszeit für die distale Verriegelung 0 vs. 88 ± 33 s (p 〈 0,0001), und die Bolzendestruktion −0,7 ± 5,2 vs. 26,8 ± 31,6 μm (p = 0,001). Die Versagerquote betrug in beiden Gruppen je 1,6 % (1 von 60 Schrauben). Beide Techniken können von einem unerfahrenen Chirurgen gleich schnell erlernt werden. Der Hauptvorteil des röntgenstrahlenfreien, mechanischen distalen Zielgerätes ist die Vermeidung von Röntgenstrahlen während der distalen Verriegelung und die präzisere Schraubenplazierung mit einer geringeren insertionsbedingten Implantatbeschädigung.
    Notes: Summary. Recently, radiation-independent aiming devices for the tibia which compensate for insertion-related implant deformation have been developed, but the benefits of such systems have not been determined. This study prospectively evaluated the duration of the nailing procedure, the length of radiation time, and the accuracy of interlocking screw placement with a radiation-independent distal aiming system and the free-hand technique. In an oblique cadaveric tibial fracture, a surgeon inexperienced with either technique performed a statically locked intramedullary nailing. For the aiming system and free-hand technique respectively, the total operation time was 25.4 ± 11.3 vs 30.9 ± 14.3 min (P = 0.029), the distal locking time was 16.7 ± 8.6 vs 21.9 ± 10.5 min (P = 0.004), the total fluoroscopy time was 9 ± 5 vs 93 ± 34 s (P 〈 0.0001), the distal locking fluorscopy time was 0 versus 88 ± 33 s (P 〈 0.0001), and the screw destruction was −0.7 ± 5.2 vs 26.8 ± 31.6 μm (P = 0.001). The failure rate was 1.6 % (1 of 60 screws) in both groups. These results suggest that aiming devices can eliminate the need for radiation during distal interlocking screw placement.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Der Orthopäde 27 (1998), S. 17-31 
    ISSN: 1433-0431
    Keywords: Key words Complex spinal injury • Serial fractures of the spine • Thoracic trauma • Abdominal trauma • Seat-belt injury • Polytrauma ; Schlüsselwörter Komplexe Wirbelsäulenverletzung • Serienverletzung der Wirbelsäule • Mehretagenverletzung der Wirbelsäule • Thoraxtrauma • Stumpfes Bauchtrauma • Intraabdominelle Verletzung • Polytrauma • Seat-belt-Verletzung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Die Autoren definieren 3 Typen einer komplexen Wirbelsäulenverletzung: Typ I bezeichnet langstreckige oder mehretagige instabile Wirbelsäulenverletzungen, Typ II Wirbelsäulenverletzungen mit gleichzeitigen intrathorakalen oder -abdominellen Läsionen und Typ III die Kombination aus einer Wirbelsäulenverletzung und einem Polytrauma. Überlagerungen zwischen den verschiedenen Typen kommen vor. Typ I: Die Häufigkeit beträgt laut einer Sammelstatistik der AG Wirbelsäule der DGU etwa 2,5 %. Betrachtete man nur thorakale Frakturen, dürfte sie allerdings höher liegen. Mehrsegmentale Läsionen erfordern langstreckige Stabilisierungen von dorsal. Durch eine sorgfältige Analyse müssen die zu versteifenden Segmente herausgefunden werden. Typ II: Führende thorakale Begleitverletzung ist die Lungenkontusion in bis zu 50 % der Fälle. Ein thorakales CT wird bei diesen Patienten im Rahmen der Erstdiagnostik empfohlen. Anzustreben ist eine frühzeitige Reposition und Stabilisierung von dorsal. Ventrale Eingriffe sind in der Anfangsphase kontraindiziert. Intraabdominelle Verletzungen kommen bei 3–4 % aller Verletzungen der Wirbelsäule vor. Alle intraabdominellen Organe sowie die Nieren können betroffen sein. Eine typische Konstellation beim „Seat-belt-Syndrom“ ist die Verletzung von Oberbauchorganen und eine Typ-B-Läsion der Wirbelsäule. Die besondere Problematik besteht in der rechtzeitigen Diagnose beider Verletzungskomponenten. Bei den meisten Patienten ist es möglich, einzeitig zunächst die Organverletzung operativ zu behandeln und dann die Wirbelsäule zu stabilisieren. Es handelt sich um eine prognostisch günstige Verletzungskombination. Typ III: 17–18 % aller polytraumatisierten Patienten weisen Verletzungen der Wirbelsäule auf. Davon sind aber nur etwa 1/3 operationspflichtige Läsionen. Von 680 Patienten mit operierten Frakturen des thorakolumbalen Übergangs waren 6,2 % polytraumatisiert (Sammelstudie DGU). Das Risiko, eine Wirbelsäulenverletzung zu übersehen, liegt beim Polytrauma bei etwa 20 %. Besteht eine Operationsindikation, sollte die Wirbelsäule in der Primärphase („day-1-surgery“) angegangen werden. Im Einzelfall muß jedoch von diesem Schema abgewichen werden. Dazu zwingen z. B. andere Verletzungen des Patienten, weitere individuelle Faktoren, ein nicht unerheblicher Zeitbedarf und Blutverlust sowie die Tatsache, daß eine nicht stabilisierte Wirbelsäulenverletzung wohl nicht die gleichen negativen Auswirkungen auf den Organismus hat wie eine unversorgte Fraktur der langen Röhrenknochen. In jedem Fall kommen anfangs an der HWS ventrale Techniken und an der B- und LWS nur dorsale Verfahren in Frage.
    Notes: Summary 3 different types of complex spinal trauma are defined: Type I means a multilevel contiguous or non contiguous unstable injury, type II is described as a spinal injury with concommitant thoracic or abdominal lesion, typ III stands for the coincidence of spinal injury and polytrauma. Overlapping of different types occurs. Type I: The incidence amounts according a german multicenter study to about 2,5 %. Multilevel injuries need to be stabilized for a long distance from posterior. With a thoroughful analysis the segments to be fused are determined. Typ II: The leading thoracic injury is a lung contusion which occurs in up to 50 % of the cases. A CT scan of the thorax during the first diagnostic screening is recommended. Early reduction and stabilization from posterior should be aimed at. During the first two weeks anterior procedures are contraindicated. Abdominal injuries are to be found in 3–4 % of all spinal injuries. All organs could be affected. A typical constallation is the “seat-belt syndrome” with lesions of the upper abdominal organs and a flexiondistraction injury of the upper lumbar spine. The main problem is to make the diagnosis of both components initially. Most of the patients may be treated in one operation by first taking care of the abdominal injury and than stabilazing the spine. The prognosis of this combination is favorable. Typ III: In 17–18 % of all polytraumatized patients lesions of the spine are to be diagnosed. From these only one third need surgical care. From 680 patients with operatively treated fractures of the thoracolumbar junction 6,2 % were polytraumatized according to the multicenter study mentioned above. The risk of missing a spinal injury in polytrauma totals approximately 20 %. Surgical stabilization should be performed in the primary phase (day-1-surgery). Additional injuries, potentially time consuming operations with a high blood loss sometimes necessitate a different approach. Non stabilized spinal injuries apparently do not have the same negative effect on the whole organism as long bone fractures. In the early phase of treatment on the C-spine only anterior procedures and on the thoraco-lumbar spine only posterior techniques should be applied.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Der Orthopäde 26 (1997), S. 1037-1045 
    ISSN: 1433-0431
    Keywords: Key words Tibial plateau fractures • Distal femur fracture • Intraarticular fracture • Osteosynthesis • Fracture-dislocation • Dislocation • External fixation ; Schlüsselwörter Tibiakopffraktur • Distale Femurfraktur • Gelenkfrakturen • Osteosynthese • Luxationen • Offene Frakturen • Fixateur externe
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Juxta- und intraartikuläre Doppelfrakturen, Gelenkfrakturen mit schwerem Weichteilschaden und Knieluxationen mit Begleitverletzungen werden als Komplextrauma des Kniegelenks definiert. Diese Verletzungen weisen eine hohe Komplikationsrate und eine schlechte Prognose auf. Sie erfordern ein spezielles Management und spezielle Versorgungsstrategien. In der Frakturbehandlung sollten heute Verfahren mit reduzierter Invasivität eingesetzt werden: perkutane Repositions- und Osteosynthesetechniken, eingeschobene Platten, Hybridfixationen. Bei Knieluxationen sollte der Zentralpfeiler mit den Kreuzbändern rekonstruiert werden, wobei augmentierte Nähte bzw. Bandplastiken zu bevorzugen sind.
    Notes: Summary Juxta- and intraarticular fractures of the knee (floating knee), intraarticular fractures with severe soft tissue damage and knee dislocations with vascular or soft tissue lesions are defined as complex knee trauma. A specific management protocol is required for these cases. Fractures should be treated with soft-tissue sparing minimal invasive reduction and fixation techniques to reduce the significant complication rate which is presently encountered. Percutaneous plate fixation, percutaneous screw osteosynthesis and hybrid fixation should be widely used in these cases. In knee dislocation, the central pivot with the two cruciate ligaments should be reconstructed using augmented repair or primary tendon grafting in every case, whereas the treatment of collateral ligament lesions depends on the specific injury type.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1433-044X
    Keywords: Schlüsselwörter Offene Tibiaschaftfraktur ; Unaufgebohrte Marknagelung ; Fixateur externe ; Key words Non-reamed-locked nailing ; Tibia Fracture ; External Fixation ; Grade IIIb-open Fracture
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Between 1987 and 1993, 41 grade 3B open tibial shaft fractures were treated with the unreamed tibial nail (URTN n = 22) or an external fixator (FIX n = 19). The method of treatment was left to the choice of the operating surgeon. Three below the knee amputations were performed, three patients died, and three were lost to follow-up. In all, 32 patients were followed up to union or at least for 1 year. There were no significant statistical differences between the two groups (P〈0.2, chi-squared, t-test) with respect to fracture type, fracture location, age, gender or accompanying injuries. The URTN group showed significantly better results regarding time to full weight-bearing (URTN 11±4 weeks; FIX 20±11 weeks, P〈0.01 M-W) Mann-Whitney Test, number of reoperations (URTN 1.04; FIX 2.89; P〈0.01 M-W), isolated bone grafting (URTN 3/22; FIX 8/19; P〈0.05 chi-squared), and average Karlström and Olerud score (URTN 30±4; FIX 26±5; P〈0.05 M-W). In all, 15/17 URTN patients and only 6/15 FIX patients achieved unlimited walking distance (P〈0.01 M-W). Time to bony union, infection, and nonunion were not significantly different between groups.
    Notes: Die Behandlung 3° offener Frakturen mit einer intramedullären Osteosynthese war bisher kontraindiziert. Zum Vergleich der Behandlungsergebnisse der ungebohrten Marknagelung und der Fixateur-externe-Behandlung führten wir eine retrospektive nicht randomisierte Studie durch. Eingeschlossen wurden 22 primär mit einem unaufgebohrten AO-Tibiamarknagel (UTN) und 19 mit einem Fixateur externe versorgten und ausbehandelten Patienten. Von 41 Patienten konnten 32 nachuntersucht werden. Hinsichtlich Frakturtyp, -lokalisation, Alter, Geschlecht und Begleitverletzungen fanden wir keine signifikanten Unterschiede. Signifikante Vorteile für den UTN fanden sich für die Zeitdauer bis zur Vollbelastung, Anzahl der isolierten Spongiosaplastiken, Zahl der Reoperationen, den Nachuntersuchungsscore nach Karlström und Olerud, sowie den Anteil an Patienten mit einer uneingeschränkten Gehstrecke. Bezüglich Infektionsrate, Pseudarthrosenrate, Anzahl der notwendigen Verfahrenswechsel und knöcherner Ausheilungszeit konnten wir keine signifikanten Unterschiede feststellen. Pintraktinfektionen waren in Fixateur-externe-typisches Problem, Bolzenbrüche typisch für die UTN-Behandlung.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1433-044X
    Keywords: Schlüsselwörter Unaufgebohrter Tibianagel ; Distale Verriegelungsbohrung ; Röntgenbildverstärker ; Key words Unreamed tibia nail ; Distal locking ; Image intensification
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: An aiming technique for an unreamed tibial nail was developed, which uses the relatively constant distance between the first transverse distal nail hole and the anterior aspect of the tibia. This aiming device is set at a distance of 12.3 mm from the anterior cortex, and fine tuning is finally resolved by use of a ``working channel'' with a 10 mm diameter from the medial side. The aiming system was tested in 20 cases in a video-documented prospective study using the unreamed tibial nail (UTN, Synthes) between July 1993 and March 1995. In all cases (100%) distal locking could be performed without image intensification. With a high percetange (55%) of open fractures (3 O3B fractures) the total operation time was 108 min (median, range 60 – 180 min). The time for distal locking (always 3 bolts) was 15.5 min (median, range 8.0 – 39.0 min), while the time for proximal locking (average 1.6±0.7 bolts) was 4.5 min (median, range 3.0 – 15.0 min). There were no major intra- or postoperative complications related to the aiming system. The major advantages are that it is not necessary to have image intensification for distal locking, there is a reduction in radiation exposure for the surgeon, and the drill holes are very precise.
    Type of Medium: Electronic Resource