Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (1)
  • 1975-1979  (2)
  • Polymer and Materials Science  (2)
  • Interventionelle Radiologie  (1)
  • 1
    ISSN: 1432-2102
    Keywords: Schlüsselwörter Endometriose ; Biopsie ; Nadel ; Magnetresonanztomographie ; Interventionelle Radiologie ; Key words Endometriosis ; Biopsy ; needle ; Magnetic resonance imaging ; Interventional radiology
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Introduction and Methods: A 0.5 T open-configuration MR system allows free access to the patient via a 58-cm-wide opening on both sides of the machine. A newly developed system for needle guidance enables the examiner to perform biopsies in combination with real-time imaging and to position laser fibers in the human body. For imaging, a 2D gradient echo sequence is used (TR 19 ms, TE 9 ms, flip angle 30 °, FOV 24 × 24 cm, slice thickness 10 mm matrix 256 × 128). The acquired images are displayed on two LCD screens localized within the MR system, thus allowing an interactive needle guidance. This procedure is illustrated by a case report. Discussion: The handling of the system for needle guidance was simple, mainly due to a real-time adaption of the scan plane to the needle direction. The possibility of multi-angulated approaches makes biopsies of hardly accessible anatomic regions feasible. Conclusion: We think that MR-guided needle positioning will play an important role in combination with thermosensitive therapies. Thermosensitivity of MR imaging allows extensive monitoring of such interventions.
    Notes: Zusammenfassung Ein offenes, interventionelles MR-Gerät (0,5 Tesla) erlaubt durch eine 58 cm breite Öffnung den Zugang zum im Gerät liegenden Patienten. Ein spezielles Punktionssystem ermöglicht es, unter Echtzeitbildgebung Punktionen vorzunehmen sowie auch Laserfasern im menschlichen Körper zu plazieren. Zur Bildgebung wird eine 2d-Gradientenechosequenz verwendet (TR 19 ms, TE 9 ms, Flipwinkel 30 °, FOV 24 × 24 cm, Schichtdicke 10 mm, Matrix 256 × 128). Die akquirierten Bilder werden dem punktierenden Radiologen auf 2 im Gerät angebrachten LCD-Monitoren angezeigt, wodurch eine interaktive Nadelführung ermöglicht wird. Es wurden bereits zahlreiche Punktionen an Patienten durchgeführt. Wichtig wird die MR-gesteuerte Punktion von Läsionen in Kombination mit der Durchführung thermosensitiver Therapien. Die der MR-Bildgebung inhärente Temperatursensitivität ermöglicht ein umfassendes Monitoring solcher Eingriffe in Echtzeit.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 23 (1979), S. 1973-1985 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Comparisons were made of differential scanning-calorimetric (DSC) thermograms of both liquid and powdered commercial phenol-formaldehyde resins. By a combination of the results from analyses under a variety of conditions, such as ambient pressure, high pressure, using freeze-dried samples, and also by direct observation of the resin-curing process in wood-veneer assemblies, the curing reactions of phenol-formaldehyde resins were found to differ for resol and novolac systems. At a heating rate of 10°C/min, the resol resin showed endothermic curing reactions at temperatures of about 150°C, while the novolac-type resin showed an exothermic peak maximum at about 160°C. Results are presented to show how DSC can be used to differentiate between a resol and novolac system.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 19 (1975), S. 215-225 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Acetylation of phenol-formaldehyde (PF) wood adhesives afforded derivatives which could be characterized by proton magnetic resonance (PMR) spectroscopy. Through use of the chemical shift and integral parameters, relative comparisons were made for the degree of polymerization of resins prepared with different molar ratios. Additionally, PMR studies of these acetylated derivatives provided a means of determining methylol content and number of aromatic protons remaining, and to some extent gave an estimate of molar formaldehyde-to-phenol ratio. Experiments conducted with Ca(OH)2 and NaOH as catalysts showed the latter to be the more effective catalyst for PF systems.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...