Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 1995-1999  (3)
  • 1965-1969  (1)
  • 1945-1949
  • 1915-1919  (2)
  • Chemistry  (4)
  • Hemorrhagic shock  (2)
Materialart
Erscheinungszeitraum
Jahr
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Journal of molecular medicine 74 (1996), S. 51-58 
    ISSN: 1432-1440
    Schlagwort(e): Tumor necrosis factor ; Hemorrhagic shock ; Leukocyte adhesion ; Intravital microscopy ; Liver
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract The relevance of tumor necrosis factor-α (TNF-α) inducing early inflammatory reactions in the liver after hemorrhagic shock, for example, leukocyte adhesion, has been well described. This study evaluated the anti-inflammatory effects of a monoclonal antibody against TNF-α (TN3.19.12) in terms of the time of application, namely, prior to shock induction, at the time of resuscitation, and after resuscitation. The hepatic micro-circulation was investigated by intravital fluorescence microscopy in female Sprague-Dawley rats undergoing severe hemorrhagic shock for 60 min and subsequent resuscitation. TN3.19.12 or placebo was given in a randomized and blinded manner either 60 min prior to shock induction, l min prior to resuscitation, or 15 min after the onset of resuscitation. The number of firmly adherent leukocytes in the livers of treated animals depended on the time of application of TN3.19.12. Leukocyte adhesion was significantly reduced when TN3.19.12 was given prior to shock induction or at the time of resuscitation and was less effective when administered after the onset of resuscitation. The results further confirm that TNF-α initiates very early pathological leukocyte adhesion in the liver 5 h following shock. Inhibition of leukocyte adhesion after shock, however, depends strongly on the time of TNF-α blocking. While TN3.19.12 prior to shock induction resulted in most effective attenuation, only very early treatment allowed limitation of posttraumatically increased leukocyte adhesion.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Journal of molecular medicine 74 (1996), S. 51-58 
    ISSN: 1432-1440
    Schlagwort(e): Key words Tumor necrosis factor ; Hemorrhagic shock ; Leukocyte adhesion ; Intravital microscopy ; Liver
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract  The relevance of tumor necrosis factor-α (TNF-α) inducing early inflammatory reactions in the liver after hemorrhagic shock, for example, leukocyte adhesion, has been well described. This study evaluated the anti-inflammatory effects of a monoclonal antibody against TNF-α (TN3.19.12) in terms of the time of application, namely, prior to shock induction, at the time of resuscitation, and after resuscitation. The hepatic microcirculation was investigated by intravital fluorescence microscopy in female Sprague-Dawley rats undergoing severe hemorrhagic shock for 60 min and subsequent resuscitation. TN3.19.12 or placebo was given in a randomized and blinded manner either 60 min prior to shock induction, 1 min prior to resuscitation, or 15 min after the onset of resuscitation. The number of firmly adherent leukocytes in the livers of treated animals depended on the time of application of TN3.19.12. Leukocyte adhesion was significantly reduced when TN3.19.12 was given prior to shock induction or at the time of resuscitation and was less effective when administered after the onset of resuscitation. The results further confirm that TNF-α initiates very early pathological leukocyte adhesion in the liver 5 h following shock. Inhibition of leukocyte adhesion after shock, however, depends strongly on the time of TNF-α blocking. While TN3.19.12 prior to shock induction resulted in most effective attenuation, only very early treatment allowed limitation of posttraumatically increased leukocyte adhesion.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Weinheim [u.a.] : Wiley-Blackwell
    Materials and Corrosion/Werkstoffe und Korrosion 19 (1968), S. 193-200 
    ISSN: 0947-5117
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Maschinenbau
    Beschreibung / Inhaltsverzeichnis: Corrosion-protected connecting devices. Recent developments. First StandardsWith connecting devices, manufacture and materials should be attuned to each other in order to attain optimum results. Through cold forming, higher yield limits can be reached which prevail even at temperatures up to 400° C and entail considerable savings in size.According to German Standards DIN 267, Sheet 11, the conventional specifications for the material alone are superseded by quality specifications. While meeting the minimum requirements to be guaranteed, the manufacturer is free to choose, from among the steels of the specified group, those steels which in conjunction with the manufacturing process produce the best results.Testing and acceptance conditions should be adapted to the application conditions. Previously standardized, conventional testing methods should be modified. The tensile test should be carried out on entire bolts; nuts subjected to the load test should be exposed to the rupture load corresponding to the quality of the bolts to which they are to be fitted. Practical experience and the results of calibration tests do not suggest that the corrosion strength of the connecting devices would be impaired by cold forming under such conditions. Appearance and corrosion resistance can be improved by electro-polishing. With nitrogen-alloyed austenitic chrome-nickel steels, the mechanical strength characteristics can be improved still further while the torrosion resistance remains at least as good.
    Notizen: Fertigungsverfahren und Werkstoffe müssen bei Verbindungselementen wechselseitig aufeinander abgestimmt werden, um optimale Werte zu erreichen. Durch Kaltumformen werden höhere Streckgrenzenwerte erreicht, die auch bei Temperaturen bis 400° C erhalten bleiben und zu erheblichen Ersparnissen in der Dimensionierung führen.An die Stelle einer reinen Werkstoffvorschrift tritt nach DIN 267 Blatt 11 die Gütergruppe. Unter Beachtung zu gewährleistender Mindestwerte kann der Hersteller für die Fertigung wechselseitig aus der gleichen Stahlgruppe die am besten geeigneten Stähle auswählen.Prüf- und Abnahmebedingungen sind den Verhältnissen des Einsatzes anzupassen. Bisher genormte und übliche Prüfanordnungen müssen geändert werden. Der Zugversuch ist an ganzen Schrauben durchzuführen, Muttern sind im Prüflastversuch bis zur Bruchlast der mit ihr zu verschraubenden Schraubengüter zu belasten. Praktische Erfahrungen und Kontrollversuche ergaben keine Beeinträchtigung der Korrosionsbeständigkeit durch das Kaltformen für Verbindungselemente unter diesen unter diesen Bedingungen. Aussehen und Korrosionsbeständigkeit lassen durch Elektropolieren steigern. Mit stickstofflegierten austenitischen Chrom-Nickel-Stählen ist eine weitere Erhöhung der Festigkeiten bei mindestens gleicher Korrosionsbeständigkeit möglich.
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    New York, NY : Wiley-Blackwell
    Journal für Praktische Chemie/Chemiker-Zeitung 98 (1918), S. 222-232 
    ISSN: 0021-8383
    Schlagwort(e): Chemistry ; Organic Chemistry
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 70 (1998), S. 1108-1108 
    ISSN: 0009-286X
    Schlagwort(e): Chemistry ; Industrial Chemistry
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    New York, NY : Wiley-Blackwell
    Journal für Praktische Chemie/Chemiker-Zeitung 98 (1918), S. 213-220 
    ISSN: 0021-8383
    Schlagwort(e): Chemistry ; Organic Chemistry
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...