Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1084
    Keywords: Key words: Thyroid ; Biopsy ; Interventional MR ; MR guidance ; Stereotaxis ; Ultrasound
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. The aim of this study was to demonstrate the clinical feasibility and utility of an interactive MR-guidance system to target and biopsy thyroid lesions, and to compare resolution between ultrasound and interventional MR imaging in the evaluation of thyroid lesions. Twenty thyroid lesions of 18 patients were interactively biopsied using a 0.5-T superconducting open magnet system. Stereotactic localization of the needle and imaging was accomplished using T1-weighted gradient-recalled-echo (GRE) images. Representative cytological material was retrieved in 16 of 20 lesions (benign cystic or colloid goiter: n = 14; one de Quervain's thyroiditis and one follicular neoplasia). Lesions smaller than 1.5 cm detected by ultrasound could not be visualized adequately on GRE images. Lesions smaller than 1.5 cm were successfully biopsied by ultrasound (three colloid and haemorrhagic goiters and one adenoma). Magnetic-resonance-guided interactive biopsies and positioning of non-ferromagnetic needles in the thyroid gland are technically feasible and safe. Compared with high-resolution ultrasound, lesions larger than 1.5 cm can be adequately visualized and biopsied. Magnetic-resonance-guided placement of non-ferromagnetic needles is no substitute for high-resolution ultrasound in clinical work-up of thyroid lesions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 97 (1995), S. 25-34 
    ISSN: 1434-6036
    Keywords: 79.60 ; 71.28
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The electronic structure of the layered compounds LaI2 and CeI2 was investigated by photoemission and electron energy loss spectroscopy. From the experimental results we are able to confirm the metallic nature of these compounds, and by using photon energy dependent measurements of the valence band we can identify the orbital character of the conduction band as essentially 5d1-like. A detailed analysis of the Ce 3d and 4f spectra yields a remarkably small 4f-5d hybridization strength, almost completely decoupling the f-electron from the conduction band, which makes CeI2 a somewhat unusual system compared to other metallic Ce compounds. Band structure calculations by Jepsen and Andersen [1] confirm these experimental results.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 97 (1995), S. 83-93 
    ISSN: 1434-6036
    Keywords: 79.60 ; 71.20 ; 71.28
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We have investigated hole doped (by lithium) and electron-doped (by nickel metal) NiO with photoemission (PES), inverse photoemission (IPES) and low and high energy electron energy loss spectroscopy (EELS). Both types of doping create empty states approximately in the middle of the charge transfer gap of undoped NiO.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...