Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (5)
  • Laparoscopy  (2)
  • Cardiac hemodynamics  (1)
  • Coagulation  (1)
  • Growth hormone  (1)
  • Acute respiratory failure
  • Inorganic Chemistry
Material
Years
Year
Keywords
  • 1
    ISSN: 1432-1238
    Keywords: Key words Antithrombin III ; Coagulation ; Disseminated intravascular coagulation ; Disseminated intravascular coagulation ; Liver failure ; Liver cirrhosis ; Liver transplantation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective: Since antithrombin III (AT III) substitution to normal activities could not be shown to have major beneficial effects in patients with end-stage chronic liver disease in a variety of clinical settings, we tested the hypothesis that substitution to supranormal activities decreases systemic procoagulant turnover better in this patient group. Design: Controlled prospective clinical study. Setting: Operating rooms at a University Hospital. Patients: Twenty-four patients with histologically verified liver cirrhosis consecutively scheduled for liver transplantation. Interventions: Nineteen patients were given an antithrombin III concentrate to achieve either 100 % (n = 10) or 175 % (n = 9) AT III activity. Control patients (n = 5) received saline 0.9 % instead. Measurements and results: Molecular markers of coagulation activation, platelet count and aggregability, and global coagulation variables were measured prior to AT III infusion and 60 min thereafter. In both AT III-treated groups thrombin-antithrombin III-complex increased significantly (p 〈 0.005), whereas prothrombin fragment F1 + 2, soluble fibrin and D-dimer concentrations, as well as other variables, did not show major changes. Conclusions: Despite thrombin inhibition by AT III in patients with end-stage chronic liver disease, systemic procoagulant turnover was not significantly decreased 60 min after AT III application even to supranormal activities. Replenishment of the inhibitory antithrombin III pool, decreased in chronic liver disease, should not be expected to slow down the baseline consumptive component of the haemostatic disorder in this patient group.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Surgical endoscopy and other interventional techniques 10 (1996), S. 668-670 
    ISSN: 1432-2218
    Keywords: Lung transplantation ; Laparoscopic fundoplication ; Laparoscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Upper midline laparotomy in the presence of pulmonary failure is often complicated by a prolonged period of mechanical ventilation postoperatively. We report the successfull performance of laparoscopic fundoplication, without ventilatory suport, in a woman with end stage pulmonary disease and resting hypercarbia, one month prior to lung transplantation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-2218
    Keywords: Laparoscopy ; Hernioplasty ; Technique ; Complications
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Smaller individual series on the outcome of laparoscopic hernioplasty techniques have been reported. This study reports on the complications of 3,229 laparoscopic hernia repairs performed by the authors in 2,559 patients. The TAPP (transabdominal preperitoneal) technique was the most frequently performed: 1,944 (60%). The totally preperitoneal technique was performed 578 (18%) times. The IPOM (intraperitoneal onlay mesh) repair was performed 345 (11%) times. The plug-and-patch technique was used 286 (9%) times and simple closure of the hernia defect without mesh was used in 76 (2%) repairs. Overall, there were 336 (10%) complications: 17 (0.5%) major and 265 (8%) minor. There were 54 (1.6%) recurrences, with a mean follow-up of 22 months. The TAPP technique had 19 (1%) recurrences and 141 (7%) complications. There were four bowel obstructions in this subgroup from herniation of small bowel through the peritoneal closure and trocar sites. The totally preperitoneal technique had no recurrence and 60 (10%) complications. The IPOM group had 7 (2%) recurrences and 47 (14%) complications. The plug-and-patch technique had 26 (9%) recurrences and 24 (8%) complications. The simple closure of the internal ring had 2 (3%) recurrences and 10 (13%) complications. Laparoscopic hernioplasty is not without complications. Training, experience, and attention to technique will prevent some of these complications.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-5233
    Keywords: Key words Segmental tubular reabsorption ; Low molecular weight protein ; Growth hormone ; Microalbuminuria
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Proximal tubular dysfunction may be implicated in the pathogenesis of diabetic nephropathy. An investigation of proximal tubular function was carried out by assessing proximal tubular sodium reabsorption and low molecular weight protein excretion in a group of patients with type 1 diabetes mellitus. Normoalbuminuric [group A, n=6, albumin excretion rate (AER) mean (range) 4 (0–10) µg/min] and microalbuminuric [group B, n=6, AER 88 (35–198) µg/min] patients with type 1 diabetes were compared with matched controls. Simultaneous lithium and growth hormone (GH) clearance and urinary β 2-microglobulin excretion were assessed. Fasting plasma glucose at the start of the study was [median (range)] 13 (10.2–15.1), 9.3 (5.9–15) and 4.1 (4.0–5.0) mmol/l in groups A, B and controls, respectively, with a mean coefficient of variation during the study of 3.9% (group A) and 5.2% (group B). There was no significant difference in plasma glucose levels between patients in groups A and B. Urinary GH excretion was raised in the patients with microalbuminuria (group B; P〈0.05), although there was no difference in serum GH clearance rate between the patient groups and controls. Urinary GH correlated with β 2-microglobulin in the diabetic subjects (r=0.665, P〈0.05) and with the degree of microalbuminuria in group B patients (r=1, P〈0.01). Urinary GH was also greater than 10 µU, the median value observed in the controls, in 5 of 6 (83%) patients in group A. Glomerular filtration rate (GFR) and effective renal plasma flow (ERPF) measured by constant infusion of 51Cr-ethylene diamine tetra-acetic acid (EDTA) and I125-para-amino hippuric acid (PAH), respectively, showed relative hyperfiltration in the normoalbuminuric group compared with controls (P〈0.05) and group B (P〈0.05). Absolute proximal reabsorption of sodium and of water (APRNa and APRH2O) was significantly higher in group A patients (P〈0.05). Although GFR was significantly higher in group A patients, no differences were found in fractional proximal reabsorption of sodium and water (FPRNa+H2O) or end proximal delivery between the patient groups and controls. Therefore, the measurement of protein reabsorptive capacity provides a more sensitive marker of renal tubular impairment in type 1 diabetes than sodium/fluid reabsorptive capacity. In patients with microalbuminuria, both glomerular and tubular damage may co-exist. Our results stress the usefulness of markers of renal tubular function in monitoring the course of diabetic nephropathy. This study also shows that assessment of GH clearance has promise as a marker of renal tubular protein reabsorptive capacity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Surgical endoscopy and other interventional techniques 10 (1996), S. 920-924 
    ISSN: 1432-2218
    Keywords: Cardiac hemodynamics ; CO2 pneumoperitoneum ; Inferior vena caval blood flow
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Background: The effects of carbon dioxide pneumoperitoneum on venous return and cardiac hemodynamics during laparoscopic surgery were studied. Methods: Twelve adult pigs underwent placement of an electromagnetic flow meter across the infrarenal vena cava (IVC) as well as placement of Swan Ganz and arterial monitoring catheters. Measurements of the flow through infrarenal IVC, cardiac output (CO), pulmonary capillary wedge pressure (PCWP), mean arterial pressure (MAP), and heart rate were recorded at baseline, 5 and 60 min following insufflation to 15 mmHg with CO2, and 5 min following desufflation. Stroke volumes and systemic vascular resistance (SVR) were calculated as well. Results: Flow through the IVC dropped by 24 and 31% at 5 and 60 min (p=0.03 and 0.02, respectively). Paradoxically, cardiac output rose by 14 and 28% at 5 and 60 min (p=0.03 at 60 min). Central venous and pulmonary capillary wedge pressures rose transiently by 35 and 36% at 5 min before returning to baseline (p〈0.01). Mean arterial pressure and heart rate remained relatively constant during insufflation. Systemic vascular resistance diminished from 938 dynes/cm/s prior to insufflation to its nadir at 60 min of 650 dynes/cm/s (p〈0.01). Conclusions: These observations suggest potentially complex interactions between the mechanical and systemic effects of the CO2 pneumoperitoneum on venous return. Transient elevations in cardiac filling pressures occur by an unknown mechanism, and a generalized enhanced inotropic state mediated via increased sympathetic outflow is observed in this hypercapnic anesthetized animal model.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...