    ISSN: 1432-055X
    Keywords: Schlüsselwörter Oxymetrie ; zerebrovenös ; Clark-Sonde ; polarographisch ; intrazerebrales Aneurysma ; Key words Jugular bulb ; Paratrend 7 ; cerebrovenous ; polarographic ; Clark electrode ; Oxygen ; Oximetry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Introduction: Recently, a compact multisensor device 0.5 mm in diameter has become available with a miniaturised Clark electrode for measuring blood oxygen tension and two optical fibres for measuring CO2 tension, pH, and temperature (Paratrend 7, Biomedical Sensors, High Wycombe, UK). We used this new probe for continuous blood gas monitoring in the jugular bulb as an alternative to the commonly used fiberoptic spectrophotometric oximetric measurement of haemoglobin saturation. Results: A 64-year-old patient was admitted for surgery of a right-sided intracranial aneurysm. During surgery, with no artefacts or evidence of catheter drift, a normal jugular venous pO2 (pjvO2) of 39±3 mmHg was measured. Over the period of weaning, two declines in pjvO2 occured (22.5 and 18.7 mm Hg) associated with a decline in CO2 tension and a rise in pH. We treated these events successfully by analgosedation, controlled ventilation with an inspired oxygen fraction of 70%, and elevation of the mean arterial blood pressure to over 100 mmHg. Extubation was possible about 24 h later. Furthermore, 3 h after extubation pjvO2 values could be monitored without difficulty despite movement of the patient. Discussion: The technique of polarographically measuring pjvO2 with a Clark-type probe appears superior to fibreoptic jugular venous oximetry due to the clearly lower incidence of faulty measurements, especially in the intensive care unit, where patients undergo frequent nursing interventions and tend to awaken. We did not even observe artefacts due to patient movement after extubation. A limitation of the new multisensor system might be the distance of 4 cm between the sensor tip and the end of the insertion catheter, which makes samples drawn for in vitro blood gas analyses to control the continuous monitoring less comparable. Improvements in the construction of the probe are recommended.
    Notes: Zusammenfassung Es wird erstmalig über den Einsatz einer neuen Multisensorsonde zur kontinuierlichen Messung der Parameter Sauerstoffpartialdruck (pjvO2), Kohlendioxidpartialdruck (pjvCO2), pH und Temperatur im Bulbus venae jugularis bei einer Patientin mit einem Aneurysma im Abgangsbereich des Ramus communicans posterior berichtet. Ergebnisse: Intra- und postoperativ war es möglich, kontinuierlich und nahezu artefaktfrei die jugularvenösen Blutgase zu erfassen. Die gemessenen Werte lagen innerhalb der Referenzbereiche (pjvO2 39±3 mm Hg). In der postoperativen Weaningphase kam es zweimal zu einem Abfall des jugularvenösen Sauerstoffpartialdrucks auf Werte von 22,5 bzw. 18,7 mm Hg. Durch Anhebung der inspiratorischen Sauerstoffkonzentration (FiO2) und des mittleren arteriellen Blutdrucks (MAP) normalisierte sich der pjvO2. Auch nach der Extubation arbeitete die Sonde störungsfrei (pjvO2 33±2,3 mm Hg). Diskussion: Unsere Ergebnisse zeigen, daß der Einsatz der polarographischen Sauerstoffpartialdruckmessung im Bulbus venae jugularis möglicherweise eine praktikable Alternative zu der bisher routinemäßig eingesetzten spektrophotometrischen jugularvenösen Katheteroxymetrie darstellt. Das Verfahren überzeugte durch seinen geringen Betreuungsaufwand. Problematisch erscheint bei der derzeitigen Konstruktion des Meßsystems die in vivo-Kalibration. Bei einer Distanz von ca. 4 cm zwischen der Sensorspitze und dem Lumen des Plastikkatheters, aus welchem die Blutprobe entnommen wird, beeinträchtigen extrakranielle Zuflüsse die Vergleichbarkeit der Sondenmeßwerte mit den in vitro-Meßergebnissen einer Blutgasanalyse.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Der Anaesthesist 45 (1996), S. 745-749 
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Zeugen Jehovas ; Erythropoetin ; Key words Jehova's witness ; Erythropoietin
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Erythropoietin, the hematopoietic growth factor, is synthesised in the kidneys and liver and regulates red blood cell production. Within the last few years, recombinant DNA technology has produced synthetic erythropoietin (rhEPO). Some patients, especially Jehova's Witnesses, will not accept blood transfusion. The perioperative administration of rhEPO increases the patients' hematocrit (HCt) to a higher than physiological level. Methods and results. We report a case of a 66-year-old female Jehova's Witness who refused blood transfusions and responded favourably to rhEPO treatment. A total hip arthroplasty was planned. A pre-treatment hemoglobin level (Hb) of 13.7 g/dl and HCt of 43% were documented. After preoperative subcutaneous application of 5000 I.E. rhEPO three times per week and daily oral substitution of 300 mg ferrous sulfate over a period of 3 weeks, the Hb increased to 15.5 g/dl and the HCt to 49%. The operation was carried out after the ninth application of rhEPO. Postoperatively, the Hb concentration was 11.8 g/dl and the HCt 35%. Therefore, postoperative administration of rhEPO was not considered indicated. No side effects of rhEPO application were noted. The patient left hospital on the 10th postoperative day. Conclusions. The case report describes perioperative management using human rhEPO in Jehova's Witnesses. Treatment with rhEPO increases preoperative Hb levels to a point making it possible to compensate for operative blood loss. RhEPO combined with daily iron substitution may be useful in patients who refuse transfusion based on religious convictions.
    Notes: Zusammenfassung Der perioperative Einsatz von rekombinantem Erythropoetin (rhEPO) zeigt neue Perspektiven in der Behandlung der postoperativen nichtrenalen Anämie im Rahmen fremdblutsparender Maßnahmen. Anhand des vorliegenden Fallbeispiels einer 66jährigen Patientin, die der Glaubensgemeinschaft „Zeugen Jehovas“ angehört und von uns auf die anstehende Implantation einer Hüfttotalendoprothese präoperativ mit dreimal wöchentlich 5000 I.E. sc. rekombinantem Erythropoetin behandelt wurde, soll die Möglichkeit des perioperativen Einsatzes dieser Substanz besprochen werden. Zu Beginn der Behandlung betrugen Hämoglobin 13,7 g/dl und Hämatokrit 43 Vol.-%. Die stationäre Aufnahme erfolgte mit einem Hämoglobin von 15,5 g/dl und einem Hämatokrit von 49 Vol.-%. Die Zahl der Retikulozyten stieg präoperativ von 5‰ auf 21‰ und postoperativ auf 31‰ und kann zur Beurteilung des Therapieeffekts herangezogen werden. Postoperativ war keine weitere Erythropoetingabe erforderlich. Die präoperative Gabe von rhEPO ist eine Bereicherung im perioperativen Management fremdblutsparender Maßnahmen. Die Indikation zur homologen Transfusion von Erythrozytenkonzentraten kann somit strenger gestellt werden.