ISSN:
1573-2568
Keywords:
ELECTROGASTROGRAPHY
;
GASTROINTESTINAL MOTILITY
;
FUNCTIONAL DYSPEPSIA
;
GASTRIC EMPTYING
Source:
Springer Online Journal Archives 1860-2000
Topics:
Medicine
Notes:
Abstract The aim of this study was to investigate gastricmyoelectrical activity in patients with functionaldyspepsia. Thirteen healthy subjects and 14 patientswith functional dyspepsia participated in the study. The electrogastrogram (EGG) recording was madein each subject for 30 min in the fasting state and 120min after a standard test meal of 475 calories. Spectralanalysis methods were applied to derive quantitative EGG parameters. There was no difference in theEGG between the patients and controls in the fastingstate. However, abnormalities in the postprandial EGGwere found in the patients. The percentage of 2-4 cpmwaves was significantly lower (74.4 ± 4.0% vs85.7 ± 1.6%, P 〈 0.03) and the postprandialincrease in EGG dominant power was significantly less(–0.52 ± 0.92 dB vs 2.24 ± 0.88 dB,P 〈 0.03) in patients than in controls. It was alsofound that the percentage of postprandial 2-4 cpm wavescould be used to differentiate the patients withfunctional dyspepsia from the healthy controls with a specificity of 100% and a sensitivity of 43%. It was concluded that a subset of patients withfunctional dyspepsia have impaired gastric myoelectricalactivity in the fed state.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1023/A:1018806913907
Permalink