    Notes: Abstract Mg+ ions were implanted into highly pure InP grown by the liquid encapsulated Czochralski (LEC) method in which the Mg concentration [Mg] was varied between 1×1015 cm−3 and 3×1020 cm–3. Two annealing methods were used: furnace annealing (FA) up to 740° C and flash lamp annealing (rapid thermal annealing, RTA) up to 900° C. For characterization, photoluminescence (PL) spectra were measured between 2K and room temperature together with Raman scattering measurements at room temperature. An emission designated by g, which was attributed to a novel energy state of an isolated acceptor, was found to be produced for a rather low value of [Mg]. In addition, a broad emission denoted by [g−g], which was ascribed to acceptor-acceptor pairs, was observed below bound exciton emissions for moderate values of [Mg]. These features were quite similar to those previously observed in acceptor-doped GaAs when the background concentration of donors is extremely low. Two additional novel emissions located far below the band-to-acceptor emission were also obtained, and each showed a remarkable energy shift towards lower energy with increasing [Mg]. The binding energies of these emissions were estimated from the temperature dependence of PL spectra and the results suggest that they are complex-type radiative recombination centers, presumably donor-acceptor-type centers. A strong broad emission centered near the band-to-acceptor emission was observed for [Mg]=3×1020 cm−3. This observation indicates a formation of a new material between In, P and Mg, which was also attested by the appearance of a new TO-like Raman signal for [Mg] greater than 1×1019 cm−3. A substantial difference of PL and Raman spectra was revealed for the two annealing methods, suggesting that the annealing behaviour of ion-implanted InP should be investigated more extensively in order to establish reliable annealing procedures.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 33 (1991), S. 72-74 
    ISSN: 1432-1920
    Keywords: Magnetic resonance imaging ; Cerebral fat embolism
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The cerebral fat embolism is a potentially serious complication of fractures but clinical cases often go undiagnosed. Two cases of clinically diagnosed cerebral fat embolism are reported, and MR images of these patients are described. While brain CT revealed no abnormality, MR imaging showed relative low-intensity areas on T1-weighted images and high-intensity areas on T2-weighted images. In one patient follow-up MR showed nearly complete resolution of the abnormal signal. MR imaging appears to be valuable for detecting the lesions in these patients.