Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (3)
  • 21.10.Hw  (1)
  • Levodopa  (1)
  • Pupil sensitivity  (1)
Material
Years
  • 1990-1994  (3)
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of comparative physiology 173 (1993), S. 455-462 
    ISSN: 1432-1351
    Keywords: Pupil sensitivity ; Dark adaptation ; Compound eye ; Zophobas morio ; Tenebrio molitor
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract Using infrared reflectometry of the deep pseudopupil, we have measured the absolute sensitivity, the dynamic range and the speed of the pupil mechanism in the acone apposition eye of two tenebrionid beetles: Zophobas morio F. and Tenebrio molitor L. The following conclusions are made from the results: 1. There is a substantial difference in sensitivity of the pupil mechanism between the two beetle species. The pupil is about 5.3 log units more sensitive in Zophobas than in Tenebrio. 2. There is also a difference in sensitivity between day and night. Surprisingly, the sensitivity is higher at day-time, and the difference is about 0.5 log units in both Zophobas and Tenebrio. 3. Light adaptation is completed faster during daytime than at night in both Zophobas and Tenebrio, whereas dark adaptation is completed about equally fast both day and night in both species. The speed of the pupil response, however, is dependent on the preceding adaptation history. 4. The pupil mechanism in both species is under the influence of a circadian rhythm, which determines the size of the pupil aperture in such a way that the pupil is maximally open when dark-adapted at night, but only partially open when dark-adapted at daytime. The differences in sensitivity and dynamics of the pupil mechanism between day and night are mainly due to the circadian rhythm setting the control range of the pupil aperture in both Zophobas and Tenebrio. The pupil differences between the two beetles are discussed regarding behavioural differences between the two species.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1041
    Keywords: Parkinson's disease ; Levodopa ; intraduodenal infusion ; PLM-test ; video ratings ; plasma level response ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Motor performance of five patients with advanced Parkinson's disease was investigated during their optimum oral therapy (conventional tablets and/or depot capsules) and during a continuous duodenal infusion of levodopa. Due to the low water solubility of the drug, conventional tablets of levodopa + carbidopa (Sinemet®) were milled and dispersed in a 1.8% aqueous methylcellulose solution. The dispersion was delivered nasoduodenally by a portable pump. The effect of levodopa in the two dosing regimens was estimated optico-electronically every 15 min and was also evaluated from videorecordings every 30 min and plasma levels of levodopa was regularly measured. Each dosage regimen the was studied twice, at a 2–4 day interval. Duodenal infusion improved motor function in all five patients and the fluctuations were reduced when compared to the oral therapy. Variation in plasma levodopa concentrations was 3–10 fold during oral therapy, while during the infusion a stable concentration was obtained. The therapeutic concentration varied from 0.3–3 μg ml−1 between patients. The relative bioavailability of levodopa in the solid preparation compared to the dispersion was in all patients 100%. Our results encourage further development of a duodenal infusion system with a levodopa dispersion for clinical use in parkinsonian patients who show severe fluctuation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1434-601X
    Keywords: 21.10.Hw ; 25.10+s ; 25.20.Lj
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The reaction6Li (γ, d) with Eγ around 60 MeV has been investigated with monoenergetic photons using a Si-Ge ΔE-E telescope, allowing accurate identification of deuterons with good energy resolution. A strict obedience of the isospin selection rule for E1 absorption, i.e. ΔT=1, is observed for the ground state transition.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...