Library

Language
Preferred search index
Number of Hits per Page
Default Sort Criterion
Default Sort Ordering
Size of Search History
Default Email Address
Default Export Format
Default Export Encoding
Facet list arrangement
Maximum number of values per filter
Auto Completion
Feed Format
Maximum Number of Items per Feed
feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Scandinavian journal of immunology 11 (1980), S. 0 
    ISSN: 1365-3083
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: An eosinophil chemotactic factor (ECF) of low molecular weight can be generated and released from human polymorphonuclear neutrophils by the calcium ionophore, phagocytosis of zymosan particles, arachidonic acid, and phospholipase A2. Since the activation of cells by the ionophore and during the phagocytic event leads to phospholipid turnover, with the subsequent generation of arachidonic acid, it is reasonable that phospholipase A2 represents the common link for ECF production. The kinetics of ECF release by phospholipase A2 is similar to the pattern observed with the various stimuli. After a rapid rise in activity a decline occurred at later times of secretion, suggesting a mechanism of inactivation. During subcellular fractionation of cells an ECF-generating component was enriched in the 200,000 g supernatant fraction, which represents the cytosol. Addition of arachidonic acid or phospholipase A2 induced ECF generation. On gel filtration analysis the ECF-generating component revealed a molecular weight of about 80,000 daltons. It is suggested that this component represents a lipoxygenase.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Journal of molecular medicine 61 (1983), S. 1095-1100 
    ISSN: 1432-1440
    Keywords: Mitral insufficiency ; Coronary heart disease ; Papillary muscle dysfunction ; Quantitative cineangiography ; Mitral valve prolapse
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary On 121 consecutive patients with coronary heart disease coronary angiography and quantitative left ventricular angiography was done with the view to aortocoronary bypass surgery. 24 (20%) had mitral regurgitation (MR) by angiographic criteria, 20 of them had MR grade I/IV, four had MR II/IV. In 23 out of 24 patients with MR quantitative left ventriculography revealed localized contraction disorders. MR was clinically diagnosed in 15 out of 24 patients. In eleven patients (48%) contraction abnormalities were localized in the inferior wall, in five cases (22%) in the anterior wall and in seven cases (30%) both in the anterior and posterior wall. Of the latter group patients with MR showed a significantly lower ejection fraction than patients without MR (p〈0,05). Furthermore the MR-group showed larger akinetic areas, preferentially located in the inferior segments 0°–240° and in the anterolateral segments 60°–90°. Three vessel disease was more frequent in this group (43%) than in the group without MR (23%). Patients with inferior wall asynergy frequently showed combined stenosis or occlusion of the right and circumflex coronary artery. In conclusion, MR in coronary heart disease is most often associated with localized contraction disorders of the left ventricle; posterior wall infarctions, multiple vessel disease and large akinetic areas are more frequent. However, the hemodynamic significance of MR in patients with chronic myocardial infarction is usually insignificant.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1434-6052
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The differential cross section of the deuteron photodisintegration was measured at a protion c.m. angle of 180 degrees and for photon energies between 180 and 730 MeV. The protons were detected in a magnetic spectrometer. The proton energy resolution varied between 30 MeV and 50 MeV FWHM. Since these are the first data at 180 degrees in this energy range a comparison can only be done with data from other laboratories extrapolated to 180 degrees and with theoretical predictions. The agreement with existing calculations is poor. Contributions of dibaryons to the cross section seem not to improve the situation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Double differential cross sectionsd 2 σ/dΩdE were measured for high energetic electrons emitted in heavy ion collisions. Electrons were detected in the energy range of 60 keV-500 keV for various target projectile combinations 66≦Z u =Z t +Z p ≦145 and projectile velocities between 7 % and 10 % of the speed of light. Clear evidence was found that these electrons stem from the united atom formed during the collision. Slope and height of the spectra are discussed with respect to the momentum distribution of strongly bound states (i.e. theL-shell) at momenta far above the mean value. In addition for the systems S, Ni, Br→Pb electrons were detected in coincidence withK x-rays of Pb. By this method the contribution of theK-shell of the combined system to the total spectrum could be separated. Binding energies of theK-shell were estimated by a slope comparison between the coincident and single spectrum. The resulting values are close to the united atom limit.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1612-1112
    Keywords: Configuration ; Chiral phases ; Gas chromatography ; Isovaline
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The D-(resp. R) configuration of isovaline (=2-ethylalanine) was proved for the peptide antibiotics antiamoebin, Tü 165 (CBS 382.62), stilbellin, samarosporin (=emerimicin IV), suzukacillin B (A), trichotoxin A-40 and A-50. This contradicts the previously reported L-configuration for isovaline in antiamoebin and emerimicin IV. The configuration was determined by GC of the N-trifluoroacetyl-isovaline n-propyl ester on glass capillary columns coated with the chiral stationary phase N-propionyl-L-valine tert.-butylamide polysiloxane (Chirasil Val). The D-configuration of the isovaline from trichotoxin A-40 was also established independently using GC of N-pentafluoro-propionyl-isovaline (+)-3-methyl-2-butyl esters on glass capillary columns coated with OV 17.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1612-1112
    Keywords: Enantioselective gas chromatography ; Chiral ketones ; Asymmetric synthesis ; Pheromones
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Oximes of chiral ketones can be separated into enantiomers by capillary gas chromatography on the chiral polysiloxanes XE-60-L-valine-(S)- or (R)-α-phenylethylamide. Usually predominantly E-isomers are formed and are better separated than Z-isomers. From time-dependent gas chromatographic measurements it can be concluded that the oximes are configurationally stable and that racemization during oxime formation is negligible. The order of elution of enantiomers depends on the structure of the ketone and is different for aliphatic and alicyclic compounds.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 415-416 
    ISSN: 0935-6304
    Keywords: Gas chromatography/mass spectrometry ; Volatile sulfur compounds from waste water ; Adsorption of air samples on tenax GC ; Mechanism of corrosion of concrete ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 553-556 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Carbohydrate enantiomer separation ; New chiral stationary phases ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: New chiral polymers have been prepared by conversion of cyano groups of polysiloxanes XE-60 and OV-225 into carboxylic groups and subsequent coupling to give the respective S-valine-R-α-phenyl-ethyl amide. In contrast to the corresponding stationary phases with S-α-phenylethyl amide groups, which have been used for the resoultion of trifluoroacetylated hexose derivatives, the new phase show high enantioselectivity for pentose and 6-deoxyhexose derivatives.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 588-595 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 404-410 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Multidimensional capillary columns ; Enantiomeric separations ; Intermediate trapping ; Mixed polarities ; Terpene alcohols ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...