Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Admittance plethysmography  (3)
  • 07.65  (2)
  • Autolysis  (2)
  • 1
    ISSN: 0014-5793
    Keywords: Autolysis ; Calcium ; Proteolysis ; m-Calpain
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0014-5793
    Keywords: Autolysis ; Calcium ; Proteolysis ; m-Calpain
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-0649
    Keywords: 42.80 ; 07.65 ; 82.80
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract This paper reports and discusses, for the first time, the all-optical remote monitoring method for spilled dispersals or leakages in air of city gas through the nearinfrared absorption of CH4 gaseous molecules as one of its major constituents, using a very low-loss optical fiber network and compact absorption cells in conjunction with high radiant InGaAsP light-emitting diodes (LEDs). For this new application, the near-infrared absorption spectra of city gas (Sendai, Japan) were measured and analyzed to find a relatively strong absorption due to thev 2 + 2v 3 combination band of CH4 molecules around the wavelength region of 1.33 μm. By using a 2-km long very low-loss silica optical fiber link, this fully optical system was demonstrated to be feasible, safe and capble of achieving reproducibly the detection sensitivity of nearly 1 Torr of CH4 gas in air, i.e., 2.6% of the lower explosion limit of CH4 density in air. This result supports the conclusion that the alloptical remote sensing system incorporating very low-loss optical fiber networks and LEDs or laser diodes (LDs) in the near-infrared region can be extensively utilized for the real-time detection and surveillance of spills or leakages of the city gas or any other gas mixtures as well as various combustible, explosive, dangerous, and toxic gases not onlyin industrial and mining complexes but also in urban and residential areas.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 38 (1985), S. 11-15 
    ISSN: 1432-0649
    Keywords: 42.68 ; 42.80 ; 07.65
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract This paper reports for the first time the fully optical remote monitoring of low-level CH4 gas with a wide area coverage of 10 km in diameter realized by utilizing ultralowloss silica optical fibre link and a compact absorption cell in conjunction with highly radiant InGaAsP and InGaAs light emitting diodes (LEDs) in the near infrared region. For this novel application, the near-infrared absorption spectra of CH4 molecules were measured and studied involving the ν2+2ν3 combination band around 1.33 μm and the 2ν3 overtone band around 1.66 μm. This fibre-optic system was demonstrated to be feasible and sufficiently sensitive and safe as being a practical CH4 gas remote sensor whose detection sensitivity is normally required to be 25% of the lower explosion limit (LEL) of CH4 gas in air. This result verifies a large potential for applying extensively to various strategic points within the environment, such as industrial and mining complexes as well as urban and residential areas, with considerably increased reability, safety and marketability over the presently available techniques.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1741-0444
    Keywords: Admittance plethysmography ; Respiration rate ; Stroke volume ; Three-channel telemetry ; Total transthoracic admittance
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract A three-channel frequency-modulation telemetry system for the noninvasive measurement of cardiac output, rate of respiration, e.c.g. and basal transthoracic admittance of the unconstrained human subject is described. Tetrapolar admittance plethysmography has been employed to obtain the transthoracic admittance and its variations corresponding to the cardiac cycle and respiratory changes. Pulse duration modulation has been used in the transmitter system. The nonlinearity of the system is less than ±2·0%. The telemetry transmitter has a range of about 100 m, it weights approximately 200 g and is contained in a box measuring 150×100×50 mm. The batteries used provide a continuous life of 20 h. The system has been used to obtain data from normal subjects in different postures with breath hold and during normal respiration.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 26 (1988), S. 641-646 
    ISSN: 1741-0444
    Keywords: Admittance plethysmography ; Arterial compliance ; Human limb ; Noninvasive measurement ; Volume elastic modulus ; Volume oscillometric method
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Arterial elasticity expressed by such indices as volume elastic modulus Ev and compliance Ca were noninvasively measured in various human limb segments; the upper arms, forearms, fingers, thighs, calves and toes. These indices are defined, respectively, as $$E_v = \Delta P/(\Delta V/\bar V_a )$$ and Ca=ΔV/ΔP, where ΔP is pulse pressure, $$\bar V_a $$ mean arterial volume and ΔV its pulsatile variation. ΔP was calculated from systolic Pas and mean Pam arterial pressures determined by volume oscillometric sphygmomanometry using the following equation: $$\Delta P = 3(P_{as} - P_{am} )/2\bar V_a $$ and the ΔV were detected by electrical admittance plethysmography at various transmural pressure Pt levels controlled by a compression cuff. The values obtained in these limb segments were compared with each other at Pt levels 0,30 and 60 mm Hg and the differences between them were discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 23 (1985), S. 43-47 
    ISSN: 1741-0444
    Keywords: Admittance plethysmography ; Arterial compliance ; Arterial volume ; Vascular unloading technique ; Volume elastic modulus
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Static and dynamic (beat-to-beat) arterial viscoelastic properties were measured noninvasively in human fingers and forearms. The volume change and pressure change were detected simultaneously by admittance plethysmography and by sphygmomanometry using the vascular unloading technique in the index and middle finger, or vice versa. These simultaneous measurements were also made on the forearms of one side and the fingers of the other side. The arterial viscoelastic properties in these segments could be successfully determined at different transmural pressure levels from 0 mm Hg to around the mean arterial pressure.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...