Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 27.40.+z  (1)
  • Colour Doppler  (1)
  • Computational Chemistry and Molecular Modeling  (1)
  • Engineering  (1)
Material
Years
Keywords
  • 1
    ISSN: 1434-601X
    Keywords: 25.20.−x ; 25.20.Lj ; 27.40.+z
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The values of the angle-integrated cross section for the decay to various low-lying states in39K following the40Ca(γ,π) reaction at a mean photon energy of 60 MeV are reported on, together with the values of the reduced Legendre coefficientsa i . The40Ca(γ,gp) and40Ca(γ,n) reactions yield the same angular cross-section values and these agree with the corresponding RPA-calculations.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1076
    Keywords: Keywords Portal vein thrombosis ; Umbilical catheterization ; Exchange transfusion ; Neonatal intensive care ; Colour Doppler
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The aetiopathology of extrahepatic portal vein obstruction is unknown. In retrospective studies, umbilical vein cannulation and sepsis have been alleged to cause portal thrombosis. This prospective study was undertaken to detect whether thrombosis and consequent obstruction of the splenoportal venous system develops after umbilical vein catheterization for exchange transfusion in newborns using Doppler ultrasound. Forty children (M = 24; F = 16) who had undergone exchange transfusion for hyperbilirubinaemia were studied at school age. Maximal duration of the venous umbilical cannulation was 120 min and sepsis did not occur. Clinical, biological and sonographic examinations were normal, except in 3 children. In 2 the left branch of portal vein could not be identified (normal variant). Conclusion Our results show that, in these children, umbilical vein catheterization did not lead to development of portal vein thrombosis. However, when other risk factors such as umbilical infection, traumatic catheterization are associated, children should be screened for obstruction of the portal vein.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 40 (1997), S. 655-687 
    ISSN: 0029-5981
    Keywords: crashworthiness ; multibody dynamics ; flexible structures ; simulation ; design ; optimization ; Engineering ; Numerical Methods and Modeling
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: Different formulations based on multibody dynamics are shown to be suitable for the development of a methodology for the impact simulation and crashworthiness design of railway vehicles. The proposed design methodology comprises different computer-aided tools of increasing complexity and accuracy which can be used with greater advantage and efficiency in the different design stages of railway stock. In general, the crashworthiness design methods and associated multibody dynamic tools which are presented in this paper require information to be obtained from numerical or experimental crush tests of specific structural components, subassemblies and critical energy absorption devices normally located in car extremities. This hybrid feature lends to the present design process various efficiency gains as a result of a better understanding of the crash and different collapse mechanisms and ease of use. To access the merits of the present methodologies some new designs are discussed and the application of the proposed numerical tools is illustrated for different structural configurations of car extremities. A formulation for the sensitivity analysis and optimization of planar constrained mechanical systems is also presented. An example of crashworthiness design of an end underframe model of a railway car is solved to demonstrate the use of the methodology. © 1997 by John Wiley & Sons, Ltd.
    Additional Material: 26 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Computational Chemistry 12 (1991), S. 1047-1057 
    ISSN: 0192-8651
    Keywords: Computational Chemistry and Molecular Modeling ; Biochemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Computer Science
    Notes: The Cα—C internal rotation in 2-methylpropionic, 2-methylthiopropionic (thiol and thion forms) and 2-methyldithiopropionic acids was studied by the ab initio SCF-MO method using 3-21G and 3-21G + d(0.65S) basis sets. Energies and structures of several conformations of these molecules, determined by gradient geometry refinement, are reported and used to assess the effects of oxygen-by-sulphur substitution on molecular properties. The nature and relative importance of intramolecular interactions involving both the α-methyl substituents and the C(=X)Y (X, Y= O or S) fragment are also discussed.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...