Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 60 (1995), S. 181-186 
    ISSN: 1432-0649
    Keywords: 42.50.-p ; 29.30.-h ; 06.00
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Wigner functions are used to describe various dephasing effects in neutron interferometry which are caused by thickness variations and density fluctuations of the phase shifter and by variations of the beam parameters. It will be shown that separated coherent Schrödinger-cat-like states, which exist when large phase shifts are applied, are extremely fragile and sensitive to any kind of imperfections. The related dephasing factor depends quadratically on the spatial separation of the coherent states which permits the definition of an upper limit of feasible coherent packet separation. The results show that dephasing is an unavoidable effect caused by intrinsic fluctuations inherent to any physical system.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1238
    Keywords: Key words Thermodilution cardiac output ; Continuous monitoring ; Postoperative intensive care ; Extubation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective: Commercially available semi-continuous cardiac output (SCCO) monitoring systems are based on the pulsed warm thermodilution technique. There is evidence that SCCO fails to correlate with standard intermittent bolus cardiac output (ICO) in clinical situations with thermal instability in the pulmonary artery. Furthermore, ventilation may potentially influence thermodilution measurements by enhanced respiratory variations in pulmonary artery blood temperature and by cyclic changes in venous return. Therefore, we evaluated the correlation, accuracy and precision of SCCO versus ICO measurements before and after extubation. Design: Prospective cohort study. Setting: Intensive care unit (ICU) of a university hospital. Patients and participants: 22 cardiac surgical ICU patients. Interventions: None. Measurements and results: SCCO and ICO data were obtained at nine postoperative time points while the patients were on controlled mechanical ventilation. Further sets of measurements were taken during the weaning phase 20 min before extubation, and 5 min, 20 min and 1 h after extubation. SCCO and ICO measurements yielded 286 data pairs with a range of 1.8–9.9 l/min for SCCO and 1.9–9.8 l/min for ICO. The correlation between SCCO and ICO was highly significant (r=0.92; p〈0.01), accompanied by a bias of –0.052 l/min and a precision of 0.56 l/min. Correlation, accuracy and precision were not influenced by the mode of respiration. Conclusions: Our results demonstrate excellent correlation, accuracy and precision between SCCO and ICO measurements in postoperative cardiac surgical ICU patients. We conclude that SCCO monitoring offers a reliable clinical method of cardiac output monitoring in ICU patients following cardiac surgery.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1238
    Keywords: Thermodilution cardiac output ; Continuous monitoring ; Postoperative intensive care ; Extubation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective Commercially available semi-continuous cardiac output (SCCO) monitoring systems are based on the pulsed warm thermodilution technique. There is evidence that SCCO fails to correlate with standard intermittent bolus cardiac output (ICO) in clinical situations with thermal instability in the pulmonary artery. Furthermore, ventilation may potentially influence thermodilution measurements by enhanced respiratory variations in pulmonary artery blood temperature and by cyclic changes in venous return. Therefore, we evaluated the correlation, accuracy and precision of SCCO versus ICO measurements before and after extubation. Design Prospective cohort study. Setting Intensive care unit (ICU) of a university hospital. Patients and participants 22 cardiac surgical ICU patients. Interventions None. Measurements and results SCCO and ICO data were obtained at nine postoperative time points while the patients were on controlled mechanical ventilation. Further sets of measurements were taken during the weaning phase 20 min before extubation, and 5 min, 20 min and 1 h after extubation. SCCO and ICO measurements yielded 286 data pairs with a range of 1.8–9.9 l/min for SCCO and 1.9–9.8 l/min for ICO. The correlation between SCCO and ICO was highly significant (r=0.92;p〈0.01), accompanied by a bias of −0.052 l/min and a precision of 0.56 l/min. Correlation, accuracy and precision were not influenced by the mode of respiration. Conclusions Our results demonstrate excellent correlation, accuracy and precision between SCCO and ICO measurements in postoperative cardiac surgical ICU patients. We conclude that SCCO monitoring offers a reliable clinical method of cardiac ouput monitoring in ICU patients following cardiac surgery.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-1238
    Keywords: Aluminium absorption ; Hyperaluminaemia ; Antacids ; Renal failure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We studied the serum aluminium levels of 30 intensive care patients receiving six daily doses of magaldrate (Riopan®) or aluminium hydroxide (Trigastril®). In both groups we found a significant rise of the serum aluminium concentration (p〈0.01) following administration of the antacid solutions. Examination on day 9 and 15 the magaldrate group showed significantly (p〈0.05) lower aluminium levels than the aluminium hydroxide group. An increase up to the critical serum aluminium level of 100 ng/ml occurred in none of the patients that all had normal or slightly impaired renal function. Therefore routine measurements of serum aluminium levels in patients without renal impairment are not considered necessary following antacid therapy. However, we recommend the use of antacids with an aluminium absorption rate as low as possible.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗