Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • pharmacokinetics  (2)
  • 42.55  (1)
  • C4B  (1)
  • Calibrator material  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 19 (1979), S. 243-245 
    ISSN: 1432-0630
    Keywords: 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract Stable step-tunable simultaneous double-wavelength emission from any branch combination of the 9.6 and 10.6 μm bands of a cw CO2 laser is reported in which the relative strengths of the two signals may be controlled.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 46 (1994), S. 261-265 
    ISSN: 1432-1041
    Keywords: Cystic fibrosis ; Cyclosporin ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract Cyclosporin (CsA) is currently the main immunosuppressive agent used in organ transplantation with considerable improvement in graft survival. Oral CsA solution is highly lipophilic, and its bioavailability may be reduced in cystic fibrosis (CF) heart-lung transplant recipients with pancreatic, gastrointestinal, and hepatic insufficiency. The bioavailability of oral CsA solution in 7 CF transplant recipients (5 male and 2 female with a mean age of 27 years and a mean weight of 49 kg) and 3 non-CF heart-lung recipients (1 male and 2 female with a mean age of 41 years and a mean weight of 60 kg) was studied. Following intravenous CsA administration, the kinetic curves were similar with no significant difference in the volume of distribution and clearance of CsA demonstrated between the CF and non-CF groups. The mean daily dose of oral CsA in 7 CF subjects (23.3 mg·kg−1) was significantly higher than the 3 non-CF heart-lung recipients (4.8 mg·kg−1). The mean maximum blood concentration of CsA for the oral dose was 776 ng·ml−1 for the 7 CF subjects, which was comparable with the mean peak values of 789 ng·ml−1 for the 3 non-CF control subjects. Poor enteral absorption of CsA probably accounts for the significantly lower mean bioavailability in the 7 CF subjects (14.9%) compared with the 3 non-CF control subjects (39.4%). The effects on the bioavailability of oral CsA solution by pancreatic enzymes (Creon) and histamine-2 antagonist (ranitidine) were also evaluated in the 7 CF subjects. No significant difference was demonstrated.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Accreditation and quality assurance 4 (1999), S. 427-430 
    ISSN: 1432-0517
    Keywords: Key words Drugs proficiency testing ; Analytical quality indicators ; Calibrator material ; Traceability
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract  Whilst it is generally agreed that measurement of immunosuppressive drugs is of value as a guide to therapy, there are a number of problems associated with the analytical techniques available. Proficiency testing schemes enable laboratories to judge their performance for the measurement of these drugs with their peers. However, current schemes only compare accuracy within-methods to document performance. This paper summarizes current findings and points out the limitations of our own schemes, and the measures we intend to use to address these deficiencies.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1437-160X
    Keywords: C4A ; C4B ; PIP ; SOL ; Immune adherence
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary C4A and C4B levels were measured in serum from 246 normal individuals. Complement-mediated solubilisation, assayed using alkaline phosphatase anti-alkaline phosphatase immune complexes (IC), correlated with both C4A and C4B levels. However, C4A and C4B levels showed no correlation with solubilisation of bovine serum albumin (BSA) ICs, or with the prevention of immune precipitation of BSA or alkaline phosphatase ICs, nor with immune adherence assayed using thyroglobulin and BSA ICs.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1573-0646
    Keywords: pharmacokinetics ; cytosine arabinoside ; delayed release ; arachis oil suspension
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary An attempt was made to create a delayed release preparation of cytosine arabinoside (araC) which could be administered subcutaneously, and would produce plasma levels similar to steady state infusion concentrations. A thixotropic suspension of araC in arachis oil and aluminium distearate was formulated. This preparation was similar to that previously used with bleomycin oil suspension and procaine penicillin. Two hundred mg/ml of araC in arachis oil containing varying amounts of aluminium distearate were administered firstly to New Zealand White rabbits and then to patients with acute myelogenous leukaemia. This preparation was well tolerated by both rabbits and patients but did not delay the release of araC from the subcutaneous tissues.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗