Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1750
    Keywords: Alveolar macrophag(s) ; Pulmonary surfactant ; Phospholipid(s) ; Bleomycin-Pulmonary injury
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Changes in the lipid metabolism of the lung during pulmonary injury were investigated by quantitative and qualitative analysis of phospholipids in pulmonary surfactant and alveolar macrophages (AM) obtained from rabbits that had been given a single transtracheal injection of bleomycin hydrochloride (BLM) 0, 7, 14, 21, and 28 days previously. BLM treatment increased the phospholipid content of both bronchoalveolar lavage (BAL) supernatant fluids and BAL cells. Furthermore, the proportion of phosphatidylcholine (PC) showed an increase in BAL cells during the development of pulmonary injury, and BLM treatment appeared to cause transformation of AM to foamy AM. Lipid analyses of the foamy AM revealed that their phospholipid content was increased, and that the percentage of PC with palmitic acid was elevated. Thus it appears that accumulation of phospholipids derived from pulmonary surfactant contributes to the increase in phospholipids and PC in BAL cells. These findings indicate that BLM treatment produces an alteration in the amount and composition of AM phospholipids, and also in BAL supernatant fluids.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-0649
    Keywords: 42.55m ; 52.70
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A rapid-frequency-scan dye laser was developed for the measurement of the velocity-distribution functions of impurity atoms sputtered due to the high-temperature plasma-surface interaction. In order to confirm the effectiveness of this rapid-scan technique, measurements of the Doppler profiles of Fe atoms sputtered by Ar ion-beam bombardment with energy 3 keV were performed. A scanning range of more than 40 pm at λ ≈300 nm was obtained with a spectral bandwidth of 1.5 ∼2 pm and good linearity. Doppler profiles were determined in various scattering conditions, and excellent performance of this technique was demonstrated. The distortion error caused by line saturation was analytically discussed, and it is shown that the effect of this error is not so serious (less than 10%) even for highly saturated excitation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...