Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1920
    Keywords: Pituitary adenoma ; Magnetic resonance imaging ; Gadolinium ; DTPA ; Normal pituitary gland
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The position of the normal pituitary gland, assessed using gadolinium-enhanced MRI was compared with the position found at surgery for pituitary adenoma in 25 patients. The tumours were five microadenomas and 20 macroadenomas. Using T1-weighted imaging, the anterior lobe could be differentiated on the sagittal image in five patients (20%) and on the coronal image in four (16%). The high intensity of the posterior lobe could be differentiated using T1-weighted sagittal imaging in 13 patients (52%). The normal pituitary gland, which enhanced more strongly than tumour, could be differentiated using Gd-DTPA-enhanced MRI on the sagittal images in 22 cases (88%) and on the coronal image in 17 (68%). In seven patients, the normal pituitary gland surrounded the tumour; it was displaced superiorly in 14 cases and superioposterorly in two but in no case was it displaced anteriorly or downwards.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 96 (1994), S. 207-212 
    ISSN: 1434-6036
    Keywords: 64.75.+g ; 74.70.Vy ; 82.60.Lf
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The liquidus compositions of Y, Sm, Gd, Dy and Yb for a melt with a Ba to Cu ratio of 3 to 5 has been investigated by a) dipping thermally equilibrated (held in the furnace for at least 10 min) MgO single crystals into the melt and analyzing the melt stuck to the MgO by ICP; b) dipping a relatively cool not thermally equilibrated Al2O3 polycrystalline rod into the melt (i.e. effective quenching) and analyzing the melt stuck to the rod by ICP. The measurements have been made in the temperature range from approximately 950° C up to about 1300° C. Following thermodynamic calculations, expressions for the liquidus lines are derived and the enthalpy of dissolution for the various RE123 and RE211 are calculated to be nearly the same for the same melt composition. Nevertheless a small increase of the enthalpy of dissolution with increasing peritetic temperature could be detected.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...