Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Der Radiologe 36 (1996), S. 306-314 
    ISSN: 1432-2102
    Keywords: Schlüsselwörter Digitale Radiographie ; Ökonomie ; Kosten ; Wirtschaftlichkeit ; Key words Digital radiography ; Economy ; Costs ; Cost-effectiveness
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Due to its high dynamic range and contrast discernibility, digital radiography offers substantial advantages compared with conventional film-screen systems. Moreover, further advantages can be assumed for radiation protection. Digital radiography also allows conventional image data to be included in PACS (Picture Archiving Communication System). These well-known advantages are faced with legal questions which are not yet settled. Cost effectiveness in using systems of digital radiography and PACS are also under dicussion. By means of examining economic efficiency and cost analysis of digital radiography systems, economic effectiveness was assessed. This was also compared with conventional alternatives. As a result, it may be assumed that amortisation is reached in three to four years. Based on lower costs for films, digital systems are more cost effective than conventional systems after this period.
    Notes: Zusammenfassung Die digitale Radiographie bietet durch ihren hohen Kontrastumfang und die hohe Kontrastauflösung wesentliche Vorteile gegenüber konventionellen Film-Folien-Systemen. Darüberhinaus sind Vorteile durch höhere Strahlenempfindlichkeit (Quantenausbeute) im Hinblick auf den Strahlenschutz zu erwarten. Zudem bietet die digitale Radiographie die Möglichkeit, bisher konventionelle Bilddaten in digitale Archivierungs- und Kommunikationssysteme einzuschleusen. Diesen bekannten Vorteilen stehen bisher ungeklärte rechtliche Fragen gegenüber. Unklar ist bisher auch die Kostensituation beim Einsatz von Systemen zur digitalen Radiographie bzw. Systemen zur Datenspeicherung, -archivierung und -kommunikation. Mit Hilfe einer Wirtschaftlichkeitsbetrachtung eines digitalen Dokumentationssystems beim Einsatz für Thoraxuntersuchungen wird im Vergleich mit Literaturangaben und Analysen durch Industrieanbieter eine Abschätzung der wirtschaftlichen Rentabilität beim Betrieb entsprechender Anlagen im Vergleich mit konventionellen Systemen unternommen. Im Ergebnis kann für die digitalen Dokumentationssysteme trotz hoher Anschaffungskosten und ohne Berücksichtigung der Ertragsseite frühzeitig von einer Kostendeckung, nach einer 3- bis 4 jährigen „Einführungs“phase von einem positiven Umschwung der Kostensituation ausgegangen werden. Bei Anwendung entsprechender Abrechnungsmodalitäten (GOÄ) ist bereits innerhalb eines Jahres eine positive Ertragssituation zu erwarten. Entsprechende Systeme sind nach den genannten Zeiträumen kostengünstiger als konventionelle Anlagen zu betreiben. Entscheidender kostenreduzierender Faktor ist die Reduktion bzw. der Wegfall des Filmverbrauchs. Zusätzlich sind positive Impulse durch günstigere Abrechnungsmodalitäten anzunehmen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European radiology 9 (1999), S. 78-84 
    ISSN: 1432-1084
    Keywords: Key words: Colorectal cancer ; Neoplasms ; Abdomen ; Neoplasm staging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. The purpose of our study was to evaluate the capability of a subsecond spiral-CT scanner using two contrast medium phases in staging of colorectal cancer. In our study we included 37 patients with proven rectum or colon carcinoma. Spiral CT was performed following tap-water enema of the colon in the arterial and venous phases of contrast medium enhancement. Our results were compared with the findings of pathological examination after surgery. The tumor's size and extension were evaluated in the arterial and venous phases, the lymph nodes in the venous phase of the CT scan. The tumor was in the rectum (n = 14), sigma (n = 11), descending colon (n = 6), and cecum (n = 6). Two-phase spiral CT had a sensitivity of 97.2 % in the arterial phase and 89.1 % in the venous phase in detecting the carcinoma. The staging results were in the arterial phase in 30 of 37 cases (81.0 %) and in the venous phase in 24 of 37 cases (64.8 %) according to pathology. In 27 of 32 patients (84.3 %) lymph nodes were detected. The correct classification of the N-stage was possible in 23 of 34 cases (67.6 %). The combined use of arterial and venous phases in staging of colorectal cancer can improve the T- and N-stage classification in comparison with using only one contrast medium phase. The arterial phase is superior compared with the venous phase for local tumor staging and the venous phase is used for lymph node assessment.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal für Praktische Chemie/Chemiker-Zeitung 47 (1893), S. 274-300 
    ISSN: 0021-8383
    Keywords: Chemistry ; Organic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...