Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Acute myelopathy  (1)
  • Fast fluid attenuated inversion recovery  (1)
  • Multiple Sclerosis  (1)
  • 1
    ISSN: 1432-1459
    Schlagwort(e): Acute myelopathy ; Magnetic resonance imaging ; Evoked potentials ; Multiple sclerosis
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Brain and spinal cord magnetic resonance imaging (MRI), multimodal evoked potentials (EPs) and cerebrospinal fluid (CSF) analysis were performed in 27 patients with acute myelopathy of unknown aetiology (AMUA), to detect the diagnostic and prognostic values of paraclinical tests at presentation. Spinal cord MRI was abnormal in 56% and brain MRI in 33% of the patients. Visual EPs were abnormal in 7%, median somatosensory EPs in 17%, tibial somatosensory EPs in 56% and motor EPs in 35% of the cases examined. Brain-stem acoustic EPs were normal in all the patients. CSF oligoclonal bands (OBs) were detected in 30% of cases. The patients were divided into subgroups according to the short-term clinical outcome (complete, partial or absent recovery). There were no significant differences among the three groups as regards MRI findings. Patients with complete recovery showed a significantly lower frequency of tibial somatosensory EP and motor EP abnormalities. According to the paraclinical findings at onset and on the basis of a long-term clinical follow-up (mean duration 24 months), 6 patients were diagnosed as having clinically definite multiple sclerosis, while 21 did not develop further neurological disturbances. Only the presence of CSF OBs was significantly more frequent in patients with definite multiple sclerosis. Our study indicates that EPs exploring spinal cord function are more powerful than spinal MRI for predicting the short-term outcome of AMUA, while the combined use of brain MRI and CSF OBs has the highest negative predictive value for the subsequent development of clinically definite multiple sclerosis.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1432-1459
    Schlagwort(e): Key words Magnetic resonance imaging ; Turbo spin echo ; Fast fluid attenuated inversion recovery ; Systemic autoimmune diseases ; Brain lesions
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Fast fluid-attenuated inversion recovery (fFLAIR) is more sensitive that conventional or fast spin echo T2-weighted magnetic resonance imaging (MRI) for detecting lesions in the brain of patients with ischemic, inflammatory, or demyelinating diseases of the CNS. We ¶investigated whether the use of fFLAIR also increases the sensitivity of brain MRI assessment in patients with systemic autoimmune disorders. Turbo spin echo (TSE) dual-echo and fFLAIR scans of the brain were obtained from patients affected by systemic lupus erythematosus (SLE) with (NSLE, n = 9) and without clinical CNS involvement (n = 15), Behçet disease (n = 5), Wegener granulomatosis (n = 9), and antiphospholipid antibody syndrome (n = 6). Brain hyperintense lesions were counted and classified according to their size and their location by two observers by consensual agreement. The total lesion volume was measured using a semiautomated technique for lesion segmentation on both TSE and fFLAIR scans. The imaging modalities showed brain hyperintense lesions in all 9 SLE patients with CNS involvement, 5 of 15 SLE patients without CNS involvement, 5 of 9 patients with Wegener granulomatosis, 1 of 5 with Behçet disease, and 3 of 6 with antiphospholipid antibody syndrome. ¶A total of 342 lesions were seen on both sequences; 88 were seen only on TSE and 54 only on fFLAIR scans. The average number of brain lesions per scan was higher on TSE than on fFLAIR, since significantly more discrete (P 〈 0.002) and small (P = 0.004) lesions were seen on TSE than on fFLAIR. The median total lesion volume, however, was similar on TSE and fFLAIR. Our study indicates that the use of fFLAIR does not improve the sensitivity of fast dual-echo MRI for detecting brain abnormalities in patients with systemic autoimmune disorders.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Springer
    Neurological sciences 17 (1996), S. 385-391 
    ISSN: 1590-3478
    Schlagwort(e): Multiple Sclerosis ; Magnetic Resonance ; Clinical Trials ; Natural History
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Beschreibung / Inhaltsverzeichnis: Sommario In questo articolo vengono presi in esame i principali contributi che le tecniche di risonanza magnetica (RM) forniscono per il monitoraggio del decorso della sclerosi multipla (SM), sia esso naturale o modificato da interventi terapeutici. Le correlazioni riscontrate tra parametri di RM ed attività a breve termine della malattia rendono appropriato l'uso di tali misure come end-point primari in trial di fase II volti ad esplorare la efficacia di nuovi trattamenti. Le correlazioni tra parametri di RM ed evoluzione clinica a lungo termine sono invece modeste nelle forme clinicamente definite di malattia e pertanto tali misure sono attualmente utilizzate esclusivamente come end-point secondari nei trial di fase III. In questo articolo vengono inoltre presentati i risultati ottenuti dall'applicazione clinica di nuove tecniche non convenzionali di RM, nonché il loro possibile ruolo futuro nel monitorare l'efficacia dei trattamenti volti a prevenire lo sviluppo di disabilità in pazienti con SM.
    Notizen: Abstract In this review the main contributions of magnetic resonance (MR) techniques in the monitoring of multiple sclerosis (MS) course, both natural or modified by treatments, are presented. MR measures well correlate with short-term disease evolution and therefore their use is appropriate as primary end-points in preliminary clinical trials evaluating the effects of new treatments. In contrast, the correlation between MR measures and long-term clinical evolution in clinically definite MS is less clear, thus indicating that such measures can be used at present only as a secondary end-point in large scale definitive trials. The results coming from the clinical application of newer MR techniques with higher pathological specificity are also presented and their possible future roles in monitoring treatment aimed at preventing development of disability in MS are discussed.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗