Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Akute-Phase-Proteine  (1)
  • Aorta  (1)
  • Biochemical parameters  (1)
  • Blood cells  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Annals of hematology 38 (1979), S. 93-101 
    ISSN: 1432-0584
    Keywords: Lymphokine ; Makrophagen-Migrationshemmfaktor (MIF) ; Biochemische Parameter ; Biologische Funktion ; Klinische Bedeutung ; Lymphokines ; Macrophage migration inhibitory factor (MIF) ; Biochemical parameters ; Biological function ; Clinical relevance
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary The first isolation and characterization of a lymphokine, the human MIF (MSF), and the availability of a specific MIF (MSF)-antibody provide an opportunity to establish a new parameter for detection of cellular immune mechanisms in various clinical situations. The precise estimation of quantitative amounts of MIF by sensitive immunochemical techniques could gain new insights into the pathogenesis of a number of clinical disorders. In addition, the exact detection of quantitative amounts of MIF in body fluids could have prognostic value.
    Notes: Zusammenfassung Die erste Isolierung und Charakterisierung eines Lymphokins, des menschlichen MIF (MSF), und die Gewinnung eines spezifischen MIF (MSF)-Antikörpers eröffnen die Möglichkeit, neue Parameter für die Bestimmung zellulärer Immunmechanismen bei verschiedenen klinischen Situationen zu gewinnen. Die genaue quantitative Bestimmung mit empfindlichen immunochemischen Techniken könnte einen Einblick in die Pathogenese verschiedener klinischer Erkrankungen ermöglichen. Zusätzlich könnte der quantitativen Bestimmung von MIF in Körperflüssigkeiten eine prognostische Bedeutung zukommen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Journal of molecular medicine 50 (1972), S. 967-972 
    ISSN: 1432-1440
    Keywords: Rheology ; haemodynamics ; direct rheography ; central pulse wave velocity ; aorta ; ventricle ; atrium ; Rheologie ; Hämodynamik ; Direktrheographie ; zentrale Pulswellengeschwindigkeit ; Aorta ; Ventrikel ; Vorhof
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Es wurde nachgewiesen, daß mit Hilfe der Direktrheographie eine differentielle Pulserfassung über der Aorta ascendens von ventral, der Aorta descendens von dorsal sowie den Herzabschnitten „Vorhofbereich” und „Ventrikelbereich” möglich ist. Dies hat zur Folge, daß die zentrale Pulswellenausbreitungsgeschwindigkeit entlang einer einheitlichen Pulswellenlaufstrecke bestimmt werden kann. Die Erfaßbarkeit der arteriellen Pulskurve im Bereich der Aorta ascendens ergibt die Möglichkeit, die Ventrikelanspannungszeit direkt auszumessen. In einer statistischen Analyse von 200 rheographischen Pulskurven ließ sich nachweisen, daß für die Direktrheographie der Vorschlag von Frank, die ZeitdifferenzΔt zwischen synchron erfaßten Pulskurven von verschiedenen Abnahmebereichen in Höhe von 20% der Amplituden zu messen, zur geringsten Fehlererwartung führt. Die Korrelation von Rheogrammamplituden der A. femoralis mit der Dauer der jeweils vorausgehenden Herzperioden bzw. Diastolen und die gleichsinnige Veränderung von Rheogrammamplituden, Ventrikelanspannungszeit und Schlagvolumen, als Beweis für den hämodynamischen Erfolg einer Kardiolyse, wurden als Beispiele dafür angeführt, daß die Rheographie zwar keine quantitativen Aussagen zuläßt, jedoch im Längsschnitt wertvolle Hinweise geben kann.
    Notes: Summary It is demonstrated that “direct rheography” makes it possible to differentially record the pulse wave of the aorta ascendens, of the aorta descendens and the waves of both the ventricular and atrial regions of the heart. This leads to the possility of obtaining the central pulse wave spreading speed from a single path of the pulse wave. The ability to record the arterial pulse wave from the aorta ascendens leads to the possibility of directly measuring the duration of isometric ventricular contraction. Statistical analysis of 200 rheographic pulse curves shows that the suggestion of Frank to measure the time intervalΔt between synchronized pulse curves from different recording regions at a height of 20% amplitude yields the smallest error. The correlation of a rheographic amplitude from the femoral artery with the duration of both the preceding cardiac cycle and diastole plus the improvements in rheographic amplitudes, duration of isometric contractions and systolic volumes following successful cardiolysis are taken as evidence to show that although rheographic data cannot be used comparatively between patients, such data may give valuable information when used throughout an individual case history.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Journal of molecular medicine 54 (1976), S. 169-171 
    ISSN: 1432-1440
    Keywords: Blutkörperchensenkungsgeschwindigkeit ; C-reaktives Protein ; Akute-Phase-Proteine ; Methode ; Erythrocyte sedimentation rate ; C-reactive protein ; Acute phase proteins ; Method
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary C-reactive protein (CRP) was isolated from pleura exudate of patients with metastasing cancer and added to plasma of healthy blood donors. Only the addition of excessive amounts of CRP (220 mg/ml) caused a notable increase in erythrocyte sedimentation rate. An immunoelectrophoretic method for the simultaneous quantitative determination of CRP together with C 3 or other acute phase reactants is described.
    Notes: Zusammenfassung C-reaktives Protein (CRP) wurde aus dem Pleuraexsudat von Patienten mit metastasierenden Tumoren isoliert und zu dem Plasma von gesunden Blutspendern zugefügt. Nur die Zugabe von extrem hohen Mengen von CRP (220 mg/ml) verursachte eine gewisse Beschleunigung der Erythrozytensenkungsgeschwindigkeit. Außerdem wird eine immunelektrophoretische Methode für die gleichzeitige quantitative Bestimmung von CRP und C 3 oder anderen akute-Phase-Proteinen beschrieben.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Clinical and experimental medicine 153 (1970), S. 331-347 
    ISSN: 1591-9528
    Keywords: Coulter method ; Cell volume distribution ; Cell deformation ; Partical pathway ; Blood cells ; Blutzellen ; Coulter-Counter ; Zellvolumenverteilung ; Zellverformung ; Partikelbahn
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Es wird eine Meßkammer nach dem Coulter Prinzip beschrieben, mit welcher man verstellbare, optisch erfaßbare Teilchenbahnen in der gesamten Meßöffnung erzeugen kann. Mit dieser Kammer wird die unterschiedliche von den Verzerrungen des elektrischen Feldes hervorgerufene Bewertung des Teilchenvolumens gezeigt; die Unterschiede können je nach Teilchenbahn bis 80% betragen. Die weitgehend symmetrischen Verteilungskurven, die einzelnen Bahnen entsprechen, werden unter Berücksichtigung der Geschwindigkeitsverteilung zu einer rechtsschiefen Gesamtverteilung zusammengesetzt. Das Verhältnis der Fläche unter der rechtsschiefen Verteilungskurve zur Fläche der Verteilungskurve der Bahn in der Lochachse beträgt 1,39. Bei vergleichend aufgenommenen Verteilungskurven mit Capillaren mit entfernbarer Zentralstrahlvorrichtung beträgt das Flächenverhältnis von allgemeiner Verteilungskurve zur Zentralstrahlverteilungskurve 1,45. Kurzzeitphotographien zeigen Bahnen von fixierten und nativen Erythrocyten im Meßlochinnern und am Meßlochrand. Dabei wird die Ausrichtung der Zellen in der Strömung und die starke Verformbarkeit der nativen Erythrocyten deutlich.
    Notes: Summary A measuring chamber is described which functions according to the Coulter principle and with which one can produce adjustable, optically distinguishable particle pathways across the entire measuring orifice. Different pathways through the orifice for particles of a given volume result in different measured values of up to 80% for the volume. The volume distribution for each individual pathway is approximately symmetrical; these individual distributions are weighted by a fluid velocity profile factor and then superimposed to yield a total, right-skewed distribution, theoretically the same as that obtained with an unmodified Coulter capillary where the volume distribution is comprised of all possible pathways. Comparison of the area of this synthetic distribution curve with that of the axial pathway yields a ratio of 1.39, in close agreement with the corresponding ratio of 1.45 for the unmodified Coulter capillary. Particle deformation and rotational alignment during passage through the orifice are also investigated. Forty-nanosecond exposure photographs of native erythrocytes and of fixed erythrocytes in the axial region and near the orifice walls show that (1) cell deformation occurs throughout the entire orifice and (2) an occasional cell near the wall rotates but none in the axial region does so.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...