Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Diseases of the colon & rectum 36 (1993), S. 1158-1160 
    ISSN: 1530-0358
    Keywords: Anal ultrasound ; Image enhancement ; Anal fistulas ; Hydrogen peroxide
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Anal endosonography is a new technique that is useful in the preoperative assessment of patients with anal fistulas. Endosonographic images are created by the reflection of sound waves from the interfaces between tissues of varying densities. In order to accentuate tissue interface layers at the level of the fistula tract, we introduced hydrogen peroxide into the fistula tract through the external opening during anal ultrasonography in two patients with recurrent anal fistula. Hydrogen peroxide injection resulted in hyperechoic imaging of the preinjection hypoechoic horseshoe fistula tract. Endosonographic findings were confirmed at the time of surgery in both patients. We conclude that hydrogen peroxide enhancement of the fistula tract is a simple, effective, and safe method of improving the accuracy of endoanal ultrasound assessment of recurrent anal fistula.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗