Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Der Radiologe 36 (1996), S. 306-314 
    ISSN: 1432-2102
    Keywords: Schlüsselwörter Digitale Radiographie ; Ökonomie ; Kosten ; Wirtschaftlichkeit ; Key words Digital radiography ; Economy ; Costs ; Cost-effectiveness
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Due to its high dynamic range and contrast discernibility, digital radiography offers substantial advantages compared with conventional film-screen systems. Moreover, further advantages can be assumed for radiation protection. Digital radiography also allows conventional image data to be included in PACS (Picture Archiving Communication System). These well-known advantages are faced with legal questions which are not yet settled. Cost effectiveness in using systems of digital radiography and PACS are also under dicussion. By means of examining economic efficiency and cost analysis of digital radiography systems, economic effectiveness was assessed. This was also compared with conventional alternatives. As a result, it may be assumed that amortisation is reached in three to four years. Based on lower costs for films, digital systems are more cost effective than conventional systems after this period.
    Notes: Zusammenfassung Die digitale Radiographie bietet durch ihren hohen Kontrastumfang und die hohe Kontrastauflösung wesentliche Vorteile gegenüber konventionellen Film-Folien-Systemen. Darüberhinaus sind Vorteile durch höhere Strahlenempfindlichkeit (Quantenausbeute) im Hinblick auf den Strahlenschutz zu erwarten. Zudem bietet die digitale Radiographie die Möglichkeit, bisher konventionelle Bilddaten in digitale Archivierungs- und Kommunikationssysteme einzuschleusen. Diesen bekannten Vorteilen stehen bisher ungeklärte rechtliche Fragen gegenüber. Unklar ist bisher auch die Kostensituation beim Einsatz von Systemen zur digitalen Radiographie bzw. Systemen zur Datenspeicherung, -archivierung und -kommunikation. Mit Hilfe einer Wirtschaftlichkeitsbetrachtung eines digitalen Dokumentationssystems beim Einsatz für Thoraxuntersuchungen wird im Vergleich mit Literaturangaben und Analysen durch Industrieanbieter eine Abschätzung der wirtschaftlichen Rentabilität beim Betrieb entsprechender Anlagen im Vergleich mit konventionellen Systemen unternommen. Im Ergebnis kann für die digitalen Dokumentationssysteme trotz hoher Anschaffungskosten und ohne Berücksichtigung der Ertragsseite frühzeitig von einer Kostendeckung, nach einer 3- bis 4 jährigen „Einführungs“phase von einem positiven Umschwung der Kostensituation ausgegangen werden. Bei Anwendung entsprechender Abrechnungsmodalitäten (GOÄ) ist bereits innerhalb eines Jahres eine positive Ertragssituation zu erwarten. Entsprechende Systeme sind nach den genannten Zeiträumen kostengünstiger als konventionelle Anlagen zu betreiben. Entscheidender kostenreduzierender Faktor ist die Reduktion bzw. der Wegfall des Filmverbrauchs. Zusätzlich sind positive Impulse durch günstigere Abrechnungsmodalitäten anzunehmen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Der Radiologe 39 (1999), S. 354-360 
    ISSN: 1432-2102
    Keywords: Schlüsselwörter Spiral-CT ; Nieren ; Indikationen ; Applikationen ; Key words Spiral CT ; Kidney ; Indications ; Applications
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary The introduction on spiral computed tomography (spiral CT) has vastly enriched the methodological diversity of computer-tomographic scans. It allows for the recording of different perfusion or excretion stages of the kidney parenchyma of the urine draining paths by carrying out long-distance, phase-identical multiple examinations of the retroperitoneum. The description of the findings which are characterized by their local and contrasts behavior is possible. The following report describes the indications and technological process of kidney spiral CT using kidney-typical intravenous contrast media. Special emphasis is put on the advantages and limits of multiple phase spiral CT. Decisive preconditions are: 1. specific clinical query, 2. selection of the corresponding phase contrasts of the kidneys and uretra or bladder, 3. exact technical and temporal adjustment of the acquisition parameters. Scanning times are in the range of seconds. The overall examination can be carried out quick and without any major strain on the part of the patient. A sound proof and a general differentiation of focal kidney lesions can be derived from the acquired data. This is also true for kidneys and ureters findings. Bladder findings can be localized and differentiated according to stage. More than two „spiral acquisitions” should be carried out with re- straint taking exposure to radiation into account. Due to the sound registration of focal lesions, its capability of reproduction and its short-time examination, the spiral CT of the kidneys can be said to be the most effective current scanning method of the retroperitoneum following clinical examinations and sonography.
    Notes: Zusammenfassung Mit der Einführung der Spiral-Computertomographie (Spiral-CT) sind die methodischen Möglichkeiten der computertomographischen Schnittbilddiagnostik erheblich erweitert worden. So können durch länger- streckige, phasenidentische Mehrfachuntersuchungen des Retroperitoneums unterschiedliche Perfusions- bzw. Ausscheidungsphasen des Nierenparenchyms und der harnableitenden Wege erfaßt werden. Die Darstellung von Befunden, die sich durch ihre Lokalisation oder ihr Kontrastverhalten unterscheiden, ist somit möglich. Im vorliegenden Beitrag werden die Indikationen und technische Durchführung der Nieren-Spiral-CT unter Einsatz nierengängiger intravenöser Kontrastmittel beschrieben. Besonders wird auf die Vorteile und die Grenzen der Mehrphasen-Spiral-CT bei der Diagnostik fokaler Nierenläsionen eingegangen. Entscheidende Voraussetzungen sind: 1. Gezielte klinische Fragestellung, 2. Auswahl der entsprechenden Phasenkontrastierung der Nieren und Ureteren bzw. der Harnblase und 3. exakte technische und zeitliche Abstimmung der Akquisitionsparameter unter Berücksichtigung der Perfusionsverhältnisse entsprechender fokaler Nierenveränderungen. Die Scanzeiten liegen im Bereich von Sekunden. Die Gesamtuntersuchung ist schnell und für den Patienten wenig belastend durchführbar. Die Untersuchungsergebnisse erlauben vor allem einen treffsicheren Nachweis und eine weitgehende Differenzierung fokaler Nierenläsionen. Nierenbecken- bzw. ureterständige Befunde sind erfaßbar. Blasenbefunde können lokalisiert und stadienabhängig eingeordnet werden. Zurückhaltung ist bei mehr als 2 „Spiralakquisitionen” im Hinblick auf die Strahlenbelastung geboten. Die Spiral-CT der Nieren stellt aufgrund ihrer sicheren Erfassung fokaler Läsionen, ihrer Reproduzierbarkeit und der schnellen Untersuchungsführung derzeit das effektivste Schnittbildverfahren des Retroperitoneums dar. Nach klinischer Untersuchung und Sonographie ist die Nieren-CT entscheidender Bestandteil der Basisdiagnostik unklarer Befunde des Retroperitoneums.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal für Praktische Chemie/Chemiker-Zeitung 47 (1893), S. 274-300 
    ISSN: 0021-8383
    Keywords: Chemistry ; Organic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...