Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Gas chromatography  (8)
  • Solid-phase extraction  (5)
  • Aqueous samples  (2)
  • Electrodialytic sample treatment  (2)
  • On-line preconcentration  (2)
  • 11
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Atomic emission detection ; Aqueous samples ; Solid-phase extraction ; Organophosphorus pesticides
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An on-line, solid-phase extraction gas chromatography atomic-emission detection (SPE-GC-AED) system has been set up using an on-column interface to transfer 100 μl of desorbing solvent to the GC part of the system. Analytical characteristics such as recovery, precision and linearity of calibration plots were comparable with those of the off-line combination of SPE-GC-AED using organophosphorus pesticides as test compounds. The fully on-line set-up causes a marked improvement in detection because of the quantitative transfer of the analytes from the SPE module to the GC: detection limits are as low as 5–20 ng l−1 for the analysis of 10 ml raw and spiked surface water samples using the phosphorus channel. Detection levels can be further enhanced by processing up to 100 ml samples. The integrated analytical system is robust. The potential of the on-line set up has been demonstrated for the analysis of surface water and waste water.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 12
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Column liquid chromatography ; On-line coupling ; Ion-exchange membrane ; Ion-pair reagent
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary In order to enable the coupling of reversed-phase liquid chromatography (RPLC) with capillary gas chromatography (GC), the performance of an anion-exchange micromembrane device has been studied to remove the ion-pair reagent methanesulphonic acid from an acetonitrile/water LC eluent. The regenerant in the membrane was tetrabutylammonium hydroxide dissolved in acetonitrile/water, which effects an anion-exchange of methanesulphonate ions for regenerant hydroxide ions. The efficiency of the exchange process was found to be 99.9%. This enabled the direct introduction of the LC eluent, free of ions and with the proper acetonitrile/water ratio, into the GC. The applicability of the on-line LC-micromembrane-GC system has been illustrated for the potential drug eltoprazine, which is quantitatively recovered with a coefficient of variation for standard solutions of 3% at the 150 μg/ml analyte level.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 13
    ISSN: 1612-1112
    Keywords: Gas chromatography ; ASPEC ; Trazodone in plasma ; Method automation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An automated sample preparation module, (the automated sample preparation with extraction columns, ASPEC), was interfaced with a capillary gas chromatograph (GC) by means of an on-column interface. The system was optimised for the determination of the antidepressant trazodone in plasma. The clean-up of untreated plasma was carried out with disposable C18 cartridges, using several washing steps. The analyte was desorbed with methanol, the extract was diluted on-line with buffer and preconcentrated on a PLRP-S trapping column. The trapping column was dried by purging with nitrogen gas. Desorption (phase switching) of the trapping column was carried out with ethyl acetate which was introduced into a retention gap using partially concurrent solvent evaporation conditions. Trazodone was determined by GC with flame ionisation detection (FID). With a 1 ml sample, this resulted in a detection limit for trazodone in plasma of 3 ng/ml. The system showed good linearity and repeatability in the range 0.01–1 μg/ml, thus covering the range of pharmacokinetic/dynamic-to-therapeutic concentrations of trazodone in plasma. Preliminary results for benzodiazepines are promising. They indicate that the use of a selective detector such as the nitrogen/phosphorus detector, is to be recommended.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 12 (1989), S. 793-796 
    ISSN: 0935-6304
    Keywords: Microcolumn liquid chromatography ; Flame photometric detection ; Organophosphorus compounds ; On-line preconcentration ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The potential of an interface for the on-line coupling of microcolumn liquid chromatography (LC)and a flame photometric detector (FPD) has been further investigated. With the micro-LC/FPD system, relatively high-molecular-weight polar compounds such as cyclic adenosine monophosphate, guanosine monophos- phate, glucose monophosphate, fructose monophosphate, and phytic acid were separated and selectively detected. In order to increase the sensitivity, on-line preconcentration with a microprecolumn inserted in the rotorof a Valcovalve has been applied. Preliminary results have shown that an injection volume of at least 500 1-11 water containing organophosphorus acids at a 5-50 ng/rnl concentration level is possible.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...