Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1619-7089
    Keywords: Positron emission tomography ; Attenuation correction ; Brain
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A hybrid method for attenuation correction (HAC) in positron emission tomography (PET) brain studies is proposed. The technique requires the acquisition of two short (1 min) transmission scans immediately before or after the emission study, with the patient and the head fixation system in place and after removing the patient from the scanner with the head fixation system alone. The method combines a uniform map of attenuation coefficients for the patient's head with measured attenuation coefficients for the head fixation system to generate a hybrid attenuation map. The HAC method was calibrated on 30 PET cerebral studies for comparison with the conventional measured attenuation correction method by ROI analysis. Average differences of less than 3% were found for cortical and subcortical regions. The HAC technique is particularly suitable in a PET clinical environment, allowing a reduction of the total study time, greater comfort for patients and an increase in patient throughput.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1619-7089
    Keywords: Single-photon emission tomography scanner ; Positron emission tomography scanner ; Brain imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The physical performances of two current state-of-the-art scanners dedicated to functional imaging of the brain, one a single-photon emission tomography (SPET) scanner and the other a positron emission tomography (PET) scanner, have been compared under identical conditions. The aim of the study was to compare the capabilities of the devices under conditions resembling the routine clinical environment, as well as to consider other issues such as radiation burden for some common investigations. Both systems have slightly less than 11-cm axial fields of view. The PET system can be operated in a septa-less (3D) mode as well as conventionally with septa (2D). The spatial resolution of both devices was less than 8 mm in all dimensions in scattering media. On average, the PET scanner's resolution was approximately 10%–15% better than the SPET system. Energy resolution on the SPET system was superior due the scintillator used [Nal(Tl)]. Sensitivity in air with a line source on the PET system was found to be ∼150 times greater in 3D and ∼25 times greater in 2D than with the SPET system. A normal subject was studied on each system in an attempt to obtain the highest quality data possible for a subjective comparison. It is clear that, while PET retains the advantages of more desirable radiopharmaceuticals and higher sensitivity, the quality obtainable from SPET devices has improved markedly. SPET may prove as useful for many clinical investigations.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1619-7089
    Keywords: Echocardiography ; Positron emission tomography ; Fluorine-18-fluoro-2-deoxy-d-glucose ; Registration
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A method has been developed to match corresponding heart regions from functional echocardiographic (Echo) and metabolic fluorine-l8-fluoro-2-deoxy-d-glucose ([18F]FDG) positron emission tomography (PET) studies in individual patients. Echo and PET images are spatially correlated by determining homologous anatomical landmarks (the two papillary muscles and the inferior junction of the right ventricle), identifiable in images obtained by both acquisition modalities. Echo-PET image registration is first performed in the plane identified by the three landmarks, using a rigid rotate-translate scale model. The registration parameters are then used to transform the whole PET volume. This allows a consistent Echo-PET regional analysis, according to a segmental subdivision of the heart. The technique was tested on patients. The overlay of Echo and PET registered images proved the reliability of realignment of the three markers and a good spatial correlation of myocardial walls. This approach to image registration could be applied to other acquisition modalities (such as magnetic resonance imaging and single-photon emission tomography), provided that the three anatomical landmarks are visualized.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...