Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1920
    Keywords: Brain ; Magnetic resonance imaging ; Cavernous angioma ; Arteriovenous malformation ; (AVM) ; Venous angioma
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Twelve patients with cerebral vascular malformations (5 cavernous angiomas, 1 thrombosed arteriovenous malformation, and 6 venous angiomas) were studied with magnetic resonance (MR) imaging. All lesions were clearly depicted. Characteristic MR findings were obtained mainly on T2-weighted images: a markedly low intensity area was always seen. The margins of arteriovenous malformation (AVM) and venous angioma were irregular while those of cavernous angioma were smooth in all planes on T2-weighted images. Gradient-echo (GrE) pulse sequences were more sensitive than T2-weighted spin echo (SE) in lesion detection. MR imaging could play an important role in the differential diagnosis of cerebral vascular malformations.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 697-718 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Blood compatibility has been studied for hydrophilic polymers such as poly(vinyl alcohol) (PVA), its derivative, and polyethylene grafted with water-soluble monomers. The surfaces in contact with electrolyte solutions have been characterized by measuring the zeta potentials. The study of plasma protein adsorption on these polymers has revealed that bovine serum albumin as well as bovine serum fibrinogen adsorbs to a lesser extent as the hydrophilicity of the polymers increases. Platelet deposition and fibrin formation, examined using platelet-rich plasma, have been found to take place less significantly on PVA as well as sodium acrylate- and acrylamide-grafted polyethylene than on nongrafted and acrylic acid-grafted polyethylene. Ex vivo experiments with canine whole blood have shown that formation of thrombus on PVA is less than on siliconized glass but increases upon heat treatment which reduces the hydrophilicity. When PVA tubes of about 1 mm diameter are anastomosed to the carotid artery of rat, the patency rate is found to depend strongly on the anastomotic technique. From the results on the zeta potential and the experiments in vitro and ex vivo it can be concluded that the material having a surface from which solvated, neutral chains are extended into the outer aqueous phase may exhibit excellent resistance to thrombus formation.
    Additional Material: 18 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...