  • 1
    ISSN: 1432-1440
    Keywords: Heart catheterisation ; Cath-lab-systems ; Computer analysis ; Haemodynamic studies ; Man-computer interaction ; Computer reliability ; Herzkatheteruntersuchung ; Herzkatheterlabor ; Computeranalyse ; Hämodynamik ; Mensch-Computer-Dialog ; Computer-Zuverlässigkeit
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Das in Aachen entwickelte Computersystem für die on-line-Analyse von hämodynamischen Daten ermöglicht im Dialog mit dem Rechner die sofortige Auswertung von Ekg, Drücken und Kälte- bzw. Farbstoffverdünnungskurven. Das Vorgehen bei der Kurvenauswertung sowie die vom Computer angestellten Berechnungen der einzelnen hämodynamischen Parameter werden beschrieben. Bei der Gegenüberstellung der ärztlich-manuellen Auswertung der auf Papier registrierten Druckkurven und der Computerresultate zeigt das in der täglichen Routine seit Oktober 1974 eingesetzte System eine sehr gute Korrelation für die Wellenerkennung und Wellenvermessung. Auch bei Verwendung verschiedener in der Praxis üblicher, flüssigkeitsgefüllter Katheter und des Tip-Manometers bestätigt sich für die Druckregistrierung in den einzelnen Herzabschnitten, daß das Computersystem für alle verwendeten Kathetermaterialien eine zuverlässige Auswertung bringt. Die flexible Konzeption des Computerprogramms mit seiner schnellen Adaptation an neue Fragestellungen erlaubt seinen Einsatz nicht nur in der klinischen Routine sondern besonders bei der Bearbeitung wissenschaftlicher Probleme im Rahmen hämodynamischer Untersuchungen.
    Notes: Summary The computer-system for the on-line-analysis of hemodynamic data developed in Aachen enables the clinical user to perform the immediate on-line analysis of ECG, pressure-curves and thermo- or dye-dilution-curves in a dialog mode. The procedure of pressure analysis as well as the calculations by the computer for the individual haemodynamic parameters are described. The comparison of the medicalmanual evaluation of the pressure curves on paper-registration and the computer results of the same measurement shows a very good correlation for wave-recognitions and wave-measurements for this system, integrated in the daily routine since 24 months. As well in the application of various fluid-filled catheters used in praxis as in tip-manometers it could be proved for the pressure-analysis in the different positions of the heart, that the computer-system produces reliable evaluations for all catheter materials used. The flexible conception of the computer program with its fast adaption to new problems allows its use not only in the clinical routine, but also and especially in the handling of scientific questions in the frame-work of haemodynamic analysis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 26 (1980), S. 363-371 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: An analysis is made of centrifugal flow of compacted porous beds through channels against high gas backpressure. One-dimensional compressible gas flow solutions are presented for concurrent and countercurrent solids/gas motion through the variable area channels. The physical process analyzed represents the flow through a newly developed centrifugal pump for feeding dry pulverized material against a pressure barrier. The objective of the analysis is to gain a basic theoretical understanding of this type of device. Good agreement is found between analytical predictions and test data obtained with an experimental pump feeding coal.
    Additional Material: 18 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 13 (1973), S. 462-468 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: It has been shown that the only way to predict the size of the PTC effect displayed by a crystalline polymer when filled with conductive particles is through the knowledge of the glass transition point of the polymer. The size of the PTC anomaly is found to decrease sharply with rise in glass transition temperature and for a polymer to be a useful PTC material its glass transition must be below 0°C. It has not been possible to explain this relationship by any of the current theories of the PTC mechanism in filled polymers.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: This work shows how laboratory experiments may provide parameters which are useful in modeling a commercial process of polystyrene devolatilization. Such processes often occur at temperatures where depolymerization of polystyrene to monomer may be significant. Polystyrene devolatilizers function by forming thin films of the polymer, with styrene loss by flashing and diffusion and styrene generation by depolymerization. The modeling parameters of importance are: depolymerization rate constant, monomer diffusivity, and thermodynamic equilibrium polymer-vapor partition coefficient. Typical levels of styrene in polystyrene in the last stage of devolatilization are 100 to 1000 ppm. Pressures and temperatures in the devolatilizer are often less than 10 torr and greater than 200°C. For styrene-polystyrene the desired parameters have not been reported, nor apparently measured, at the concentration, pressure and temperature levels of interest.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 14 (1974), S. 706-716 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: This is a study of materials which are positive-temperature-coefficient resistors. Such materials, composed of conductive particles dispersed in a crystalline polymeric matrix, have been found to be of limited stability. An example is carbon black in high-density polyethylene. On repeated cycling through the anomaly temperature or on extensive heating at or above the anomaly temperature, the room temperature resistivity rises and the anomaly height falls to zero. This phenomenon has been shown to be caused by the absorption of oxygen by the polymer matrix which alters the structure, reduces the crystallinity, and induces an unusual form of crosslinking of a reversible nature.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗