Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of molecular medicine 53 (1975), S. 171-176 
    ISSN: 1432-1440
    Keywords: Atrial standstill ; intra-atrial electrogram ; His bundle electrogram ; Vorhofstillstand ; Intraatriales Elektrogramm ; His Bündel Elektrogramm
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Vorgestellt wird ein 70jähriger Patient, bei dem die diagnostischen Kriterien eines chronischen Vorhofstillstandes erfüllt sind. Es wird auf die Seltenheit dieser Rhythmusstörung hingewiesen, der Wert verschiedener diagnostischer Kriterien diskutiert und die möglichen elektrophysiologischen Grundlagen besprochen.
    Notes: Summary A patient with a persistent form of atrial standstill is presented. The rarity of this arrhythmia is emphasized and the possible mechanisms involved and the diagnostic criteria are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1440
    Keywords: Heart catheterisation ; Cath-lab-systems ; Computer analysis ; Haemodynamic studies ; Man-computer interaction ; Computer reliability ; Herzkatheteruntersuchung ; Herzkatheterlabor ; Computeranalyse ; Hämodynamik ; Mensch-Computer-Dialog ; Computer-Zuverlässigkeit
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Das in Aachen entwickelte Computersystem für die on-line-Analyse von hämodynamischen Daten ermöglicht im Dialog mit dem Rechner die sofortige Auswertung von Ekg, Drücken und Kälte- bzw. Farbstoffverdünnungskurven. Das Vorgehen bei der Kurvenauswertung sowie die vom Computer angestellten Berechnungen der einzelnen hämodynamischen Parameter werden beschrieben. Bei der Gegenüberstellung der ärztlich-manuellen Auswertung der auf Papier registrierten Druckkurven und der Computerresultate zeigt das in der täglichen Routine seit Oktober 1974 eingesetzte System eine sehr gute Korrelation für die Wellenerkennung und Wellenvermessung. Auch bei Verwendung verschiedener in der Praxis üblicher, flüssigkeitsgefüllter Katheter und des Tip-Manometers bestätigt sich für die Druckregistrierung in den einzelnen Herzabschnitten, daß das Computersystem für alle verwendeten Kathetermaterialien eine zuverlässige Auswertung bringt. Die flexible Konzeption des Computerprogramms mit seiner schnellen Adaptation an neue Fragestellungen erlaubt seinen Einsatz nicht nur in der klinischen Routine sondern besonders bei der Bearbeitung wissenschaftlicher Probleme im Rahmen hämodynamischer Untersuchungen.
    Notes: Summary The computer-system for the on-line-analysis of hemodynamic data developed in Aachen enables the clinical user to perform the immediate on-line analysis of ECG, pressure-curves and thermo- or dye-dilution-curves in a dialog mode. The procedure of pressure analysis as well as the calculations by the computer for the individual haemodynamic parameters are described. The comparison of the medicalmanual evaluation of the pressure curves on paper-registration and the computer results of the same measurement shows a very good correlation for wave-recognitions and wave-measurements for this system, integrated in the daily routine since 24 months. As well in the application of various fluid-filled catheters used in praxis as in tip-manometers it could be proved for the pressure-analysis in the different positions of the heart, that the computer-system produces reliable evaluations for all catheter materials used. The flexible conception of the computer program with its fast adaption to new problems allows its use not only in the clinical routine, but also and especially in the handling of scientific questions in the frame-work of haemodynamic analysis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Journal of molecular medicine 56 (1978), S. 351-354 
    ISSN: 1432-1440
    Keywords: Angiocardiography ; Left ventricle ; Premature ventricular contractions ; Coronary heart disease ; Videometry ; Angiokardiographie ; Linker Ventrikel ; Extrasystolen ; Koronare Herzkrankheit ; Videometrie
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Die Kontrastmitteldarstellung des linken Ventrikels im Rahmen der Herzkatheteruntersuchung hat große Bedeutung in der Beurteilung der Dynamik des Myokards und der Herzklappen. Die Injektion von Kontrastmittel in den linken Ventrikel führt häufig zum Auftreten von Extrasystolen. Eine quantitative Analyse des Kontraktionsablaufs ist in diesen Fällen nicht möglich. Dieser Nachteil der Methode wird umgangen, wenn das Kontrastmittel in den rechten Vorhof injiziert wird. Die nach der Lungenpassage erzielte Darstellung des linken Ventrikels ist bei Anwendung der beschriebenen Technik frei von Extrasystolen und erfüllt die Kriterien der quantitativen Ventrikulographie. Die Erfahrungen der Arbeitsgruppe beruhen auf 57 Kontrastmitteldarstellungen des linken Ventrikels bei 32 Patienten mit verschiedenen Herzerkrankungen. Technik, Indikationen und spezielle Anwendungsmöglichkeiten (Videometrie, Druck/Volumen-Beziehung) werden dargestellt.
    Notes: Summary Left ventricular angiography as a diagnostic means is of considerable importance in the evaluation of myocardial and valvular dynamics. The injection of contrast medium into the left ventricle often causes premature ventricular contractions. In these cases quantitative analysis of the contraction pattern is impossible. This can be avoided by injection of the contrast medium into the right atrium. The technique described allows to obtain ventriculograms which meet the criteria for quantitative angiocardiography. 57 ventriculograms have been performed in 32 patients with various cardiac abnormalities. The study describes the technical procedure, the indications and limitations. Furthermore special applications are discussed (videometry, pressure-volume relationship).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Nuclear Physics 66 (1965), S. 638-640 
    ISSN: 0029-5582
    Keywords: Nuclear reactions
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Pflügers Archiv 349 (1974), S. 369-376 
    ISSN: 1432-2013
    Keywords: Intraventricular Volume ; Heart Volume ; Ultrasonic Heart Catheter
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A method for the measurement of intraventricular volume by means of an ultrasound echo technique (intraventricular catheter) is described. From two diameters measured and a correction factor the volume is calculated. The correction factor was derived from measurements on excised non beating hearts. In experiments on beating hearts of 6 anesthetized dogs stroke volume was measured simultaneously with the ultrasonic catheter and the dye dilution technique. Under normal physiological conditions there was a good agreement between the two methods. The difference of 4.0±1.7% (N=24) was not significant. When the hearts were enlarged or made smaller, large deviations occurred which were consistent in their direction, while the scattering remained almost as small as under basic conditions. Only further work can show whether the method can be developed to a reliable procedure for routine measurement of stroke volume under a variety of conditions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1433-8580
    Keywords: Peripheral resistance ; Intravascular volume ; Vasoactive drugs ; Strömungswiderstand ; Intravasales Volumen ; Vasoaktive Substanzen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung An narkotisierten Hunden wurde der relative Einfluß vasoaktiver Substanzen (Isoproterenol, Papaverin, Nitroglycerin) auf den Strömungswiderstand und das intravasale Volumen des Gesamtkreislaufs untersucht. Die genannten Substanzen wurden so dosiert, daß der arterielle Mitteldruck um 20 mm Hg gesenkt wurde. Anschließend wurde er durch eine Transfusion auf den Kontrollwert zurückgebracht. Die zur Kompensation des arteriellen Druckes benötigte Blutmenge wurde registriert. Der Druck in Aorta und beiden Ventrikeln, das Herzminutenvolumen, die Herzfrequenz,dp/dt max und das Gesamtblutvolumen wurden gemessen. — Unter der Bedingung der Blutdruckkompensation kam es bei allen verabreichten Substanzen zu einer signifikanten Zunahme des intravasalen Volumens: Isoproterenol + 20,1%, Papaverin + 18,5%, Nitroglycerin + 12,1%. Der Strömungswiderstand war unter Isoproterenol und Papaverin gesenkt (—60,5 bzw. —47,9%), während Nitroglycerin keine Änderung bewirkte. Das beschriebene Verfahren erlaubt die quantitative Erfassung der extrakardialen Komponente der Wirkung vasoaktiver Substanzen.
    Notes: Summary In anesthetized dogs the relative effects of isoproterenol, papaverine, and nitroglycerin on peripheral resistance and intravascular volume were studied. The drugs were administered in a dose which produced a standardized decrease in mean arterial pressure (20 mm Hg). Then, under continuous infusion of the drugs, the control value of mean arterial pressure was reestablished by transfusion. The amount of blood required was determined. The pressure in aorta and both ventricles, cardiac output, heart rate,dp/dt max, and total blood volume were measured. — In all experiments intravascular volume was significantly increased: isoproterenol +20.1%, papaverine + 18.5%, nitroglycerin + 12.1%. Peripheral resistance was diminished by isoproterenol and papaverine (—60.5 and —47.9% resp.); this effect could not be demonstrated with nitroglycerin. The technique described in this study permits the assessment of extracardial actions of vasoactive drugs.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Trauma und Berufskrankheit 2 (2000), S. S41 
    ISSN: 1436-6274
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...