    ISSN: 1432-2013
    Keywords: Key words Arteries ; Conductivity ; Conductance method ; Double indicator dilution method ; Shear rate ; Intravascular ultrasound
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A double indicator dilution technique for determining the mean cross-sectional area (CSA) of a blood vessel in vivo is presented. Analogous to the thermodilution method, dilution of hypertonic saline was measured by an electrical conductance technique. Because the change in conductance rather than absolute conductance was used to calculate CSA, pulsatile changes in shear rate of blood and conductance of surrounding tissues had no effect on the data. To calculate CSA from an ion mass balance, cardiac output was needed and estimated from the thermodilution curve using the same “cold” (hypertonic) saline injection. The mean CSA, obtained from this double indicator dilution method (CSAGD), was compared with the CSA obtained from the intravascular ultrasound method (IVUS) in 44 paired observations in six piglets. The regression line is close to the line of identity (CSAGD = −1.83 + 1.06⋅CSAIVUS, r = 0.96). The difference between both CSAs was independent of the diameter of the vessel, on average −0.99 mm2± 2.64 mm2 (mean CSAGD = 46.84 ± 8.21 mm2, mean CSAIVUS = 47.82 ± 9.08 mm2) and not significant. The results show that the double indicator dilution method is a reliable technique for estimating the CSA of blood vessels in vivo.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-9686
    Keywords: Conductivity ; Erythrocytes ; Ultrasound ; Shear stress
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract A modified conductance method to determine the cross-sectional areas (CSAs) of arteries in piglets was evaluated in vivo. The method utilized a conductance catheter having four electrodes. Between the outer electrodes an alternating current was applied and between the inner electrodes the induced voltage difference was measured and converted into a conductance. CSA was determined from measured conductance minus parallel conductance, which is the conductance of the tissues surrounding the vessel times the length between the measuring electrodes of the conductance catheter divided by the conductivity of blood. The parallel conductance was determined by injecting hypertonic saline to change blood conductivity. The conductivity of blood was calculated from temperature and hematocrit and corrected for maximal deformation and changes in orientation of the erythrocytes under shear stress conditions. The equations to calculate the conductivity of blood were obtained from in vitro experiments. In vivo average aortic CSAs, determined with the conductance method CSA (G) in five piglets, were compared to those determined with the intravascular ultrasound method CSA(IVUS). The regression equation between both values was CSA (G) =−0.09+1.00·CSA(IVUS) r=0.97, n=53. The mean difference between the values was −0.29% · 5.57% (2 standard deviations). We conclude that the modified conductance method is a reliable technique to estimate the average cross-sectional areas of the aorta in piglets. © 1999 Biomedical Engineering Society. PAC99: 8780-y, 8437+q, 8719Nn
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 213-219 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The aim of this study was to investigate the bone response to three different types of titanium (Ti) alloys and hydroxyapatite (HA) coated titanium alloy by histological and histomorphometrical analysis. Therefore, implants made of these materials were inserted into the tibia of rabbits. Implantation times were 6 and 16 weeks. The histological evaluation included measurement of the amount of bone apposition and analysis of the bone reaction and interface characteristics around the implants. The results demonstrated no marked differences in bony reaction to the different implant materials. In addition, the HA coatings showed loss of thickness. © 1993 John Wiley & Sons, Inc.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 66 (1994), S. 1229-1230 
    ISSN: 0009-286X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Plasma-sprayed ceramic coatings of fluorapatite (FA), magnesiumwhitlockite (MW), and hydroxylapatite (HA), and noncoated Ti-6Al-4V alloy (Ti) implants were evaluated histologically and histomorphometrically in a goat animal study. Cylindrical Ti-6Al-4V plugs were plasma-spray-coated with FA, MW, and HA. Noncoated, gritblasted Ti plugs served as controls. The plugs were implanted into the right femur and left humerus of 20 adults goats. The results were evaluated using descriptive histology and histomorphometry. The histomorphometry consisted of measurements of bone apposition and coating thickness. The results demonstrated that FA showed a high amount of bone apposition without signs of degradation or dissolution. MW showed considerable reduction in thickness and at 12 weeks an adverse tissue reaction. However, at 25 weeks the amount of bone apposition was significantly increased compared with the 12-week implants. HA revealed considerable and progressive reduction in thickness and at 25 weeks a lower amount of bone apposition than FA and MW. At 12 weeks the Ti implants did reveal bone apposition, although frequently localized fibrous tissue was visible. At 25 weeks the Ti implants did not differ in bone apposition from the HA implants. Further studies are necessary on the effect of degradation or dissolution of HA on the compatibility with bone. © 1993 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 28 (1994), S. 1047-1054 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: This study reports on the soft-tissue response to titanium fiber mesh percutaneous implants. The implants were inserted in the backs of 15 rabbits. The surgical procedure was performed in two steps: implantation of the subcutaneous part of the implants and, after 3 months, fixation of the percutaneous part into the subcutaneous part. Two and 6 months after insertion the animals were sacrificed and the implants, with their surrounding tissues, were processed histologically. Light microscopic analysis demonstrated that only one implant showed considerable skin retraction in the percutaneous area. Around the rest of the implants no downgrowth or only a very limited epidermal downgrowth was observed. Furthermore, the fiber mesh material showed good biocompatible behavior. These results confirm the previous finding that sintered titanium fiberweb structures are effective for the stabilization of percutaneous devices located in soft tissues and can improve their performance. © 1994 John Wiley & Sons, Inc.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A rat bone marrow cell culture was used to evaluate the osteogenic potential of amorphous and crystalline thin calcium phosphate (Ca/P) coatings. The coatings were deposited on titanium discs using a radiofrequency magnetron sputter procedure. Amorphous and crystalline plasma spray Ca/P coated and noncoated titanium discs served as reference material. The cellular behavior was analyzed with quantitative (attachment and proliferation rates) and qualitative (scanning electron microscopy) techniques. No significant differences were found in cell attachment and proliferation rates between the various materials. Scanning electron microscopy showed extracellular matrix formation after 18 days of culture on amorphous plasma-sprayed and the two types of magnetron sputtered coatings. Furthermore, no severe degradation of the magnetron sputtered coatings was observed. They even appeared to induce apatite formation. On basis of the results, we conclude that magnetron sputtering appears to be a promising method to manufacture bioactive ceramic coatings. © 1995 John Wiley & Sons, Inc.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 37 (1997), S. 539-547 
    ISSN: 0021-9304
    Keywords: in vivo ; soft-tissue reaction ; scanning electron microscopy ; confocal laser scanning microscopy ; three-dimensional reconstruction ; implant interface ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: It has been suggested that during wound healing microtextured surfaces can alter events at the interface between implant surface surface and surrounding tissues. To investigate this phenomenon, smooth and microtextured silicone rubber implants were implanted subcutaneously in rabbits for 3, 7, 42, and 84 days. The textured implants possessed parallel surface microgrooves and ridges with a width of 2.0, 5.0, and 10.0 μm. All grooves had a depth of approximately 0.5 μm. SEM observation showed fibroblasts, erythrocytes, lymphocytes, macrophages, fibrin, and collagen on all implant surfaces after 3 and 7 days. After 42 and 84 days only little collagen, a small number of fibroblasts, but no inflammatory cells were seen on the implant surfaces. The fibroblasts were not oriented along the surface grooves on all textured surfaces. Three-dimensional reconstruction of CLSM images and LM images showed no significant differences between the thickness of the capsules surrounding the smooth and those surrounding the microgrooved implants. In contrast, LM did show a significantly lower number of inflammatory cells and a significantly higher number of blood vessels in the capsules surrounding the microgrooved implants. Differences between the 2.0, 5.0, and 10.0 μm grooved implants were not detected. Our results concerning the capsule thickness suggest that the depth of our grooves was not sufficient to facilitate mechanical interlocking, but the cause for the observed differences in inflammatory response and number of blood vessels remains unclear. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 37, 539-547, 1997.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 37 (1997), S. 60-67 
    ISSN: 0021-9304
    Keywords: heat treatment ; calcium phosphate ; coating ; sputter ; implant ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: This study evaluated the effect of rapid heating with infrared radiation on the physico-chemical and morphological properties of radio frequent (RF) magnetron-sputtered calcium phosphate (Ca-P) coatings. About 2.5 μm thick Ca-P coatings were deposited on titanium disks and cylinders. These specimens were left untreated or were heat treated by infrared radiation at 300, 400, 500, 600, and 700°C for 4, 7, 11, 17, and 24 s. Subsequently, the specimens were immersed in simulated body fluid (SBF) for 1 day, 1 week, and 5 weeks. X-ray diffraction measurements showed that heating at 500°C or higher resulted in an increase of coating crystallinity. In addition, FT-IR measurements revealed the appearance of OH peaks in the spectra of samples treated at 500-700°C. Electron probe microanalysis showed that after 5 weeks of immersion about 40-50% of the coatings heat treated at 500 and 600°C was maintained. The coatings heat treated at 700°C showed no dissolution at all. On the other hand, as-coated and 300°C treated films were dissolved within 1 day. Scanning electron microscopy of the samples showed that directly after heat treatment no apparent cracks were present in the coatings. On the basis of these findings, we conclude that rapid heating with infrared radiation around 600°C is the best heat treatment for RF magnetron-sputtered coatings. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 37, 60-67, 1997.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 0021-9304
    Keywords: surface topography ; plasma etching ; cellular orientation ; focal adhesion point ; in vitro ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: During this study, microtechnology and plasma etching were used to produce gratings 1.0 (TiD01), 2.0 (TiD02), 5.0 (TiD05), and 10.0 μm wide (TiD10) into commercially pure titanium wafers. After incubation of rat dermal fibroblast (RDFs) on these surfaces for 3 days, the cells were observed with scanning electron (SEM), transmission electron (TEM), and confocal laser scanning microscopy (CLSM). Results showed that the RDFs as a whole and their stress fibers oriented strictly parallel to the surface pattern on the TiD01 and TiD02 surfaces. On the TiD05 and TiD10 surfaces, this orientation was not observed. In addition, TEM and CLSM demonstrated that the focal adhesion points (FAP) were located mainly on the surface pattern ridges. TEM revealed that FAP were wrapped occasionally around the edges of the ridges. Only the RDFs on both the TiD05 and TiD10 surfaces protruded into the grooves and possessed FAP on the walls of the grooves. Attachment to the groove floor was observed only on the TiD10 textures. Comparison of these results with earlier observations on microtextured silicone rubber substrata suggests that material-specific properties do not influence the orientational effect of the surface texture on the observed RDF cellular behavior. The proliferation rate of the RDFs, however, seems to be much higher on titanium than on silicone rubber substrata. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res, 40, 425-433, 1998.