Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 38 (1996), S. 322-324 
    ISSN: 1432-1920
    Keywords: Demyelinating disease ; Sclerosis ; Brain ; Magnetic resonance imaging ; Computed tomography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We report a case of Balò's concentric sclerosis. In the past, the diagnosis was usually made post mortem. In this case, we found that CT demonstrated only low-density lesions, but not their concentric pattern. However, MRI showed a striking feature, reminiscent of histopathology of Balò's concentric sclerosis, and played an important role in antemortem diagnosis of this rare demyelinating disease.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 38 (1996), S. 322-324 
    ISSN: 1432-1920
    Keywords: Key words Demyelinating disease ; Sclerosis ; Brain ; Magnetic resonance imaging ; Computed tomography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We report a case of Balò's concentric sclerosis. In the past, the diagnosis was usually made post mortem. In this case, we found that CT demonstrated only low-density lesions, but not their concentric pattern. However, MRI showed a striking feature, reminiscent of histopathology of Balò's concentric sclerosis, and played an important role in antemortem diagnosis of this rare demyelinating disease.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 28 (1990), S. 212-216 
    ISSN: 1741-0444
    Keywords: Cardiac output ; Electrical field mapping ; Impedance cardiography ; Impedance plethysmography ; Stroke volume
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract The cardiogenic impedance signal from band electrodes placed in the traditional position around the neck and lower thorax was studied by mapping the location of the signal on the sternum using 10 cm strip electrodes in eight male subjects. The band current electrodes on the neck and waist were replaced with 10cm strip electrodes on the forehead and 10 cm below the xiphisternal joint, respectively, with only small changes in the dZ/dt peak amplitude and Zo. Similarly, using a strip voltage pickup electrode at the level of the xiphisternal joint resulted in very small changes in the waveform. The amplitude of dZ/dt measured between the xiphisternal joint and points along the sternum remains small until approximately 10cm below the suprasternal notch, after which it increased linearly to the top of the neck. An average of 17 per cent and 24 per cent of the dZ/dt signal and 24 per cent and 22 per cent of the Zo signal for supine and standing, respectively, occurs above the suprasternal notch. Replacing the current electrodes with strip electrodes on the forehead and waist caused only small changes in the signal. The position of the neck strip electrode is more critical.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 29 (1991), S. 505-510 
    ISSN: 1741-0444
    Keywords: Cardiac functions ; Impedance cardiography ; Respiratory effects
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract The respiratory effects on impedance-determined cardiac indices ((dZ/dt)min, stroke volume (SV), the Heather index (HI) and the O-wave) were measured at 100 kHz on ten normal males in the supine and sitting positions. The respiration was synchronised to 1/5th of the heart rate using voluntary cardiorespiratory synchronisation (VCRS). Digital filtering was used to eliminate breathing artefacts in the impedance signals, SV, (dZ/dt)min and HI were statistically higher during inspiration than expiration. Ensemble-averaging of (dZ/dt) signals using the R spike of the ECG as reference will lose beat-to-beat information and statistically reduce (dZ/dt)min because of the variation of RZ intervals during respiration Zo increased with inspiration and decreased in expiration delayed by one heart beat. The ratio of the O-wave height to (dZ/dt)min changed by 48 per cent from the beginning of inspiration to the end of expiration. Based on the timing and direction of the changes, the data imply that the traditional band impedance measurement is more closely related to the right heart event than to that of the left heart.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 30 (1992), S. 556-561 
    ISSN: 1741-0444
    Keywords: Filtering ; Impedance cardiography ; Respiration
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Physics Edition 22 (1984), S. 1645-1653 
    ISSN: 0098-1273
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: The CO2 permeation coefficient and the difficient were measured using the permeation time-lag method for films of atactic polystyrene and high-density polyethylene, each as a function of uniaxial draw ratio. The reduction of permeability with draw ratio is observed for polystyrene and for polyethylene. In the latter it is associated with an increase in crystallinity. In both cases the premeability decreases and the solubility constant remains unchanged. The reduction of permeability is thus caused only by the reduction in diffusion of CO2 in the drawn polymers. The mechainism is different for the two polymers, as is confirmed by measurements of birefringence, glass transition temperature, and crystallinity.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Physics Edition 21 (1983), S. 1815-1823 
    ISSN: 0098-1273
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: The differential orientation of polymer chains has been measured in polystyrene (PS)/poly(2,6-dimethyl-1,4-phenylene oxide) (PPO) compatible blends. Density measurements are reported as a function of binary blend composition at 23°C. Drawing was performed by solid-state coextrusion. PS/PPO blend compositions of 90/10 and 75/25 were drawn within sandwiches of polyethylene at 145°C and isotactic polypropylene at 155°C, i.e. at ca. 25°C above the glass transition temperatures of the two blends. The change in Fourier-transform infrared dichroisms on drawing these blends was measured at 906 and 1190 cm-1, corresponding to predominantly PS and PPO, respectively. The orientation of PS and PPO was observed as a function of draw ratio λ in the range 1-5; orientations increased with λ for both PS and PPO in both blends but to different degrees. Both polymers decreased in orientation with increasing PPO content. Annealing with fixed ends showed that the PPO chains disorient more slowly than those of PS. All binary systems were found to be amorphous and compatible.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...