Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1433-044X
    Keywords: Schlüsselwörter PKW-Unfall ; Beckenringverletzung ; Verletzungsmechanismus ; Klassifikation ; Prävention ; Key words Car accident ; Pelvic injury ; Injury mechanism ; Classification ; Prevention
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract During 1985 and 1993, 7,410 persons were injured in traffic accidents in the area of Hanover. Of these, 306 (4.1%) sustained a pelvic girdle injury. In 139 cases (45%), the pelvic girdle injuries were further classified (Pennal and Tile) and a technical reconstruction of the accident situation was performed. 52% were type A, 27% type B and 21% type C injuries. Some 47% of the casualties were vehicle occupants, 31% pedestrians, 12% motorcyclists and 10% cyclists. In restrained vehicle occupants pelvic girdle injuries occurred mostly in accidents with a delta-v of more than 30 km/h, whereas in unrestrained vehicle occupants, pedestrians and cyclists they also occurred with lower delta-v or collision speed. The percentage of type B and C injuries increased with higher velocities. In addition to further improvements in passive safety, lower collision speed or delta-v is necessary to reduce or prevent pelvic girdle injuries. The reconstruction of pelvic girdle injury mechanism in traffic accidents is possible, when both technical and medical parameters are considered.
    Notes: Zusammenfassung Zwischen 1985 und 1993 wurden 7.410 Verkehrsunfallverletzte im Großraum Hannover erfaßt; 306 (4,1%) erlitten eine Beckenringverletzung mit einem AIS〉2. In 139 (45%) Fällen erfolgte die Klassifikation der Beckenringverletzung nach Pennal und Tile und eine vollständige technische Rekonstruktion; 52% waren danach Typ-A-, 27% Typ-B- und 21% Typ-C-Verletzungen. Bei den Verletzten handelte es sich um 46% PKW-Insassen, 31% Fußgänger, 12% Motorradfahrer, 10% Fahrradfahrer und 1% LKW-Insassen. Die Beckenringverletzungen traten bei gurtgeschützten Fahrzeuginsassen fast ausschließlich bei einem Δ-v von über 30 km/h auf, dagegen bei ungeschützten Verkehrsteilnehmern (Fußgänger und Radfahrer) und bei nicht gurtgeschützten Fahrzeuginsassen auch schon bei Anprallgeschwindigkeiten bzw. Δ-v von 10–20 km/h. Bei höheren Geschwindigkeiten stieg der Anteil der B- und C-Verletzungen. Neben weiteren Verbesserungen der passiven Sicherheit ist zur Verminderung oder Vermeidung von Beckenringverletzungen eine Verringerung der “Unfallgeschwindigkeit” nötig. Unter Berücksichtigung aller technischen und klinischen Parameter wird eine Rekonstruktion des tatsächlichen Unfallmechanismus von Beckenringverletzungen ermöglicht.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Der Unfallchirurg 101 (1998), S. 201-203 
    ISSN: 1433-044X
    Keywords: Key words Acetabular fractures • Cerclage wires • Closed application ; Schlüsselwörter Acetabulumfrakturen • Cerclagen • Gedeckte Applikation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Die offene Reposition und interne Stabilisierung stellt heutzutage die Standardtherapie für dislozierte Acetabulumfrakturen dar. Die Stabilisierung erfolgt in der Regel mit Platten und Schrauben. Nur vereinzelt wurde bisher der Einsatz von Cerclagen als Repositionshilfe, aber auch zur definitiven Fixation der Fraktur angegeben. In der vorliegenden Arbeit wird ein neues Instrument, welches auf der Modifikation eines Standardknochenraspartoriums beruht, vorgestellt. Es erlaubt weitestgehend gedeckt eine Cerclage über das sog. „2. Fenster“ des ilioinguinalen Zugangs durch die Incisura ischiadica major zu ziehen. Eine komplette Freilegung der Außenseite des Beckens ist damit nicht notwendig.
    Notes: Summary Open reduction with internal stabilization is considered to be the standard therapy for the treatment of displaced acetabular fractures. The internal fixation is routinely achieved by the use of plates and screws. The use of cerclage wires and cables as a reduction aid and definitive implant for stabilization has only occasionally been reported in the literature. The indication was mostly limited to use in elderly patients with insufficient bone stock. A newly instrument developed on the basis of a standard bone elevator is presented. It allows a safe, semiclosed application of a cerclage wire around the greater ischiatic notch through use of the second window of the ilioinguinal approach. A wide dissection at the “outside” of the pelvis is not necessary.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...