Library

Language
Preferred search index
Number of Hits per Page
Default Sort Criterion
Default Sort Ordering
Size of Search History
Default Email Address
Default Export Format
Default Export Encoding
Facet list arrangement
Maximum number of values per filter
Auto Completion
Feed Format
Maximum Number of Items per Feed
feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 70 (1991), S. 1107-1114 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Eddy current induced in a metal by a coil carrying an alternating current may be perturbed by the presence of any macroscopic defects in the material, such as cracks, surface indentations, or inclusions. In eddy-current nondestructive evaluation, defects are commonly sensed by a change of the coil impedance resulting from perturbations in the electromagnetic field. This paper describes theoretical predictions of eddy-current probe responses for surface cracks with finite opening. The theory expresses the electromagnetic field scattered by a three-dimensional flaw as a volume integral with a dyadic kernel. Probe signals are found by first solving an integral equation for the field at the flaw. The field equation is approximated by a discrete form using the moment method and a numerical solution found using conjugate gradients. The change in probe impedance due to a flaw is calculated from the flaw field. Predictions of the theory are compared with experimental impedances due to eddy-current interaction with a rectangular surface breaking slot. Good agreement is found between predictions and the measurements.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 117 (2002), S. 3951-3955 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: A c(2×4) LEED pattern is observed for methylidyne (CH) chemisorbed on Pt{110}(1×2) at a saturation coverage of 0.25 ML. Density functional calculations reveal that methylidyne is preferentially adsorbed in the fcc three-fold hollow site on the {111} microfacet of the reconstructed surface. A structure for the ordered overlayer is thus proposed, and both through-metal and through-space interactions are considered as possible causes for this unexpected long-range coherence. We argue that entropic effects may be implicated. © 2002 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 114 (2001), S. 5765-5773 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: We discuss the results of large-scale density functional calculations for (7×7) benzene adsorption on the ferromagnetic substrate Ni{111}. Adsorption at the bridge site, with C–C bonds parallel to the [2¯11] direction, is found to be energetically preferred over the [1¯10]-oriented hcp site suggested by electron diffraction experiments. We discuss the roles of intermolecular forces and anisotropic molecular vibrations in accounting for this apparent discrepancy. Furthermore, our analysis of charge and spin densities clarifies the relationship between preferred adsorption sites and the symmetry of frontier molecular orbitals. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 57 (1986), S. 1880-1882 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Over the past three years, the total TMX-U diagnostic data base has grown to exceed 10 Mbytes from over 1300 channels; roughly triple the originally designed size. This acquisition and processing load has resulted in an experiment repetition rate exceeding 10 min per shot using the five original Hewlett–Packard HP-1000 computers with their shared disks. Our new diagnostics tend to be multichannel instruments, which, in our environment, can be more easily managed using local computers. For this purpose, we are using HP series 9000 computers for instrument control, data acquisition, and analysis. Fourteen such systems are operational with processed format output exchanged via a shared resource manager. We are presently implementing the necessary hardware and software changes to create a local area network allowing us to combine the data from these systems with our main data archive. The expansion of our diagnostic system using the parallel acquisition and processing concept allows us to increase our data base with a minimum of impact on the experimental repetition rate.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 52 (1988), S. 1880-1882 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Conical features produced on excimer laser ablated polymers are shown to provide a sensitive technique for determining ablation thresholds. This has been applied to polyimide, polyethylene terephthalate, polyethylene, and nylon 66 ablated using the 157 nm vacuum ultraviolet F2 laser.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of the American Chemical Society 75 (1953), S. 5899-5901 
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1365-2214
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine , Psychology
    Notes: To examine the possible use of height velocity (HV) as a growth screening tool, annual HV data calculated from height measurements made by school nurses were compared with those based on an auxologist's measurements in 20 short school children. The subjects were 12 primary school children (seven girls, five boys) with a mean (± SD) age of 5·9(0·6) years and eight secondary school children (six girls, two boys) with a mean (± SD) age of 11·8 (0·4) years. Heights were measured by the school nurses, separated by an interval of 1 year. Mean HV of the primary school children when assessed by school nurses was 5·92 cm/year compared with 5·97 cm/year when assessed by the auxologist. Mean (± SD) HV standard deviation score (HVSDS) was 0·03 (0·97) and 0·10 (1·15) respectively. Mean HV of the secondary school children when assessed by school nurses was 6·04 cm/year compared with 5·63 cm/year when assessed by the auxologist. Mean (± SD) HVSDS was −0·8 (2·1) and −1·21 (1·54) respectively. Of eight children (three primary, five secondary) identified by the auxologist as having HV 〈 25th centile of Tanner and Whitehouse standards only four were identified by school nurses (one primary, three secondary). One child identified by school nurses to have HV 〈 25th centile was found by the auxologist to be above the 25th centile. We conclude that HV assessment may fail to identify significant pathology in the community and that accurate height measurement rather than HV should be the principal referral criterion.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Alimentary pharmacology & therapeutics 9 (1995), S. 0 
    ISSN: 1365-2036
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Somatostatin and octreotide inhibit basal and stimulated pancreatic secretion, stimulate reticuloendothelial system activity, modulate the cytokine cascade and are cytoprotective with respect to the pancreas. These effects of somatostatin and octreotide suggest that both drugs may be useful either in the treatment of pancreatic disorders, or in preventing acute pancreatitis following procedures on the pancreas.In recent years it has become clear that somatostatin is a useful and effective therapy for severe acute pancreatitis and in preventing complications following endoscopic retrograde cholangiopancreatography (ERCP), whereas octreotide has no beneficial effect and may be deleterious in both these indications. The differences in the therapeutic efficacy of somatostatin and octreotide in acute pancreatitis and ERCP appears to be related to their differential effects on sphincter of Oddi motility—the native hormone relaxing, and the analogue increasing, its contractility. Consequently, any beneficial effects of octreotide in both acute pancreatitis and ERCP are offset by the increased contractility of the sphincter of Oddi, which results in retention of activated enzymes within the pancreas and further autodigestion of the gland.Somatostatin and octreotide are equally effective in promoting the closure of pancreatic fistulae. However, the time to closure after commencement of therapy is much more variable and longer in patients treated with subcutaneous octreotide than those receiving intravenous somatostatin, possibly as a result of fluctuations in pancreatic enzyme secretion between consecutive administrations of the hormone.Furthermore, the initial potent inhibitory effect of octreotide on pancreatic secretion is lost after 7 days of continuous subcutaneous administration. Therefore, in terms of cost-effectiveness, somatostatin would appear to be the treatment of choice for pancreatic fistulae.Octreotide markedly reduces the complication rates after elective pancreatic surgery. It remains to be established whether somatostatin is as effective as octreotide in this indication.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Alimentary pharmacology & therapeutics 9 (1995), S. 0 
    ISSN: 1365-2036
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Macromolecules 28 (1995), S. 4650-4659 
    ISSN: 1520-5835
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...