Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1365-2516
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Summary.  High-dose factor prophylaxis, defined as the infusion of 25–40 factor (F) VIII International Units (IU) kg bodyweight (bw)−1≥ × 3 per week, started at age 1–2 years of life in boys with severe haemophilia A prevents the development of significant bleed-related arthropathy. However, programmes of prophylaxis are very expensive and venous access is a challenge. To ascertain patterns of prophylaxis in Canada during the period of a global shortage of recombinant FVIII concentrate a survey was conducted in 2001. The response rate was 83% and the survey identified 247 inhibitor-negative haemophilia A cases receiving prophylaxis, defined as the regular administration of FVIII at least once weekly, from 14 Canadian haemophilia treatment centres. The median age of the group identified was 13 years (range: 1–65) and 95% of cases had severe haemophilia A defined by a circulating factor level of 〈1%. The median FVIII infusion dose was 26 (range: 16–33) IU kg−1; infusions were administered ≥ × 3 per week in 67% of cases. High-dose factor prophylaxis was used most frequently in boys 〈5 years of age (23 of 28 cases, 82%) as compared with 56% (56 of 100), 66% (40 of 61) and 62% (36 of 58) of males ages 5–12, 13–18 and 〉18 years. Prophylaxis accounted for 50% of the annual Canadian FVIII consumption and was a major driving force in the 10% increase (=19.3 million FVIII IU) in the FVIII consumption in Canada in the 4-year period 1999–2003. Given the economic implications of increased use of prophylaxis prospective studies are warranted to better define optimal prophylaxis regimens in the haemophilia A population.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1365-2516
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Haemophilia 7 (2001), S. 0 
    ISSN: 1365-2516
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Chemical synovectomy has been used for the last three decades as an alternative for surgical synovectomy in the treatment of chronic haemophilic synovitis. Comparable results have been obtained with the many different radionuclides used: decreased bleeding, decreased pain and stable range of motion, in more than 50% of treated patients. Yttrium 90Y and Phosphorus 32P seem to be the isotopes of choice. Osmic acid and rifampicine have been used in a relatively small number of subjects. Global result of treatment with these two pro-ducts seems to be less favourable than with radionuclides. Late effects of chemical synovectomy are not known.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1365-2516
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The clinical, plain X-ray and magnetic resonance imaging (MRI) findings were studied in 13 haemophilic joints previously treated with radiosynoviorthesis. 32P had been injected into the joints at a median of 16 years earlier in an attempt to halt recurrent haemorrhage. Prior to 32P injection, the majority of joints demonstrated bone damage evident on plain X-ray, secondary to recurrent haemorrhage. At the follow-up evaluation we found plain X-rays were adequate to identify cysts, erosions and cartilage loss in these very damaged joints. MRI was superior to clinical examination and plain X-ray in identifying synovial hyperplasia and effusions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1365-2516
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Summary.  The international MRI expert subgroup of the International Prophylaxis Study Group (IPSG) has developed a consensus for magnetic resonance imaging (MRI) scales for assessment of haemophilic arthropathy. A MRI scoring scheme including a 10 step progressive scale and a 20 step additive scale with identical definitions of mutual steps is presented. Using the progressive scale, effusion/haemarthrosis can correspond to progressive scores of 1, 2, or 3, and synovial hypertrophy and/or haemosiderin deposition to 4, 5, or 6. The progressive score can be 7 or 8 if there are subchondral cysts and/or surface erosions, and it is 9 or 10 if there is loss of cartilage. Using the additive scale, synovial hypertrophy contributes 1–3 points to the additive score and haemosiderin deposition contributes 1 point. For osteochondral changes, 16 statements are evaluated as to whether they are true or false, and each true statement contributes 1 point to the additive score. The use of these two compatible scales for progressive and additive MRI assessments can facilitate international comparison of data and enhance the accumulation of experience on MRI scoring of haemophilic arthropathy.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1365-2516
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Summary.  Two retrospective studies have suggested that exposure to factor VIII (FVIII) in early infancy is associated with an increased risk of FVIII inhibitor development. We prospectively studied 11 infants who needed replacement therapy for bleeding episodes before the age of 2 years. They received activated recombinant factor VII (rFVIIa) concentrate on demand, with the intention of postponing their first exposure to FVIII after 2 years of age. Thirty-three bleeding episodes were treated with 154 doses of rFVIIa with no evidence of adverse effect. Bleeding was controlled in 27 of 33 episodes. Mouth bleeds were most difficult to treat. The use of rFVIIa allowed postponement of the use of FVIII for a mean of 5.5 months (median 4, range 0–12) but in only three of 11 children could be the first exposure to factor postponed after the age of 2 years. With this modest effect of rFVIIa in postponing the first exposure to FVIII, more convincing evidence for the benefit of such a postponement will have to be demonstrated before rFVIIa could be recommended for this indication.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1365-2516
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Summary.  Routine infusions of factor VIII to prevent bleeding, known as prophylaxis, and other intensive therapies are being more broadly applied to patients with haemophilia. These therapies differ widely in replacement product usage, cost, frequency of venous access and parental effort. In order to address residual issues relating to recommendations, implementation, and evaluations of prophylaxis therapy in persons with haemophila, a multinational working group was formed and called the International Prophylaxis Study Group (IPSG). The group was comprised of haemophilia treaters actively involved in studies of prophylaxis from North America and Europe. Two expert committees, the Physical Therapy (PT) Working Group and the Magnetic Resonance Imaging (MRI) Working Group were organized to critically assess existing tools for assessment of joint outcome. These two committees independently concluded that the WFH Physical Examination Scale (WFH PE Scale) and the WFH X-ray Scale (WFH XR Scale) were inadequately sensitive to detect early changes in joints. New scales were developed based on suggested modifications of the existing scales and called the Haemophilia Joint Health Score (HJHS) and the International MRI Scales. The new scales were piloted. Concordance was measured by the intra-class correlation coefficient of variation. Reliability of the HJHS was excellent with an inter-observer co-efficient of 0.83 and a test-retest value of 0.89. The MRI study was conducted using both Denver and European scoring approaches; inter-reader reliability using the two approaches was 0.88 and 0.87; test-retest reliability was 0.92 and 0.93. These new PT and MRI scales promise to improve outcome assessment in children on early preventive treatment regimens.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1365-2516
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Summary.  Venous access is essential for delivery of haemophilia factor concentrate. Wherever possible, peripheral veins remain the route of choice, and the use of central venous access devices (CVADs) should be limited to cases of clear need in patients with caregivers able to exercise diligence in CVAD care and should continue no longer than necessary. CVADs are of recognized value for repeated administration of coagulation factors in haemophilia, particularly for prophylaxis and immune tolerance therapy and in young children. Evidence to guide best practices has been fragmentary, and standardized methods for CVAD usage have yet to be established. We have developed management recommendations based upon available published evidence as well as extensive clinical experience. These recommendations address patient and CVAD selection; CVAD placement, care and removal; caregiver/patient guidance; and complications, including infection and thrombosis. In the absence of inhibitors, ports are recommended, primarily because of fewer associated infections than with external catheters. For patients with inhibitors, ports also appear to be associated with fewer infections. Infection is the most frequent complication, and recommendations to prevent and treat infections are supported by extensive clinical data and experience. Strict adherence to handwashing and aseptic technique are essential elements of catheter care. Evidence-based data regarding the detection and treatment of CVAD-related thrombotic complications are limited. Caregiver education is an integral part of CVAD use and the procedural practices of users should be regularly re-assessed. These recommendations provide a basis for sound current CVAD practice and are expected to undergo further refinements as new evidence is compiled and clinical experience is gained.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1365-2516
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Summary.  Immunoadsorption is occasionally used as an adjuvant measure in the treatment of subjects with coagulation factor inhibitors. We reviewed our recent 3-year period experience with this procedure in 10 subjects. Immunoadsorption was used in the context of an immune tolerance protocol for 3 subjects with severe congenital deficiency in factor VIII, IX, and XIII; it was effective in lowering the level of inhibitor but immune tolerance was not achieved. It allowed successful use of porcine factor VIII in 4 cases of acquired hemophilia and in one case of inhibitor in mild hemophilia A. This therapeutic approach seems to be more useful in acquired hemophilia than in severe congenital factor deficiencies with inhibitors.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1365-2516
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Summary.  Effective treatment of haemophilic arthropathy requires a detailed evaluation of joint integrity. Methodological assessment of magnetic resonance imaging (MRI) scores are needed to assure reproducibility of measurements when comparing results of clinical trials conducted in different centres. We compared the reliability of two MRI scoring systems for assessment of haemophilic arthropathy: one progressive system that displays the most severe change and one additive system that depicts osteochondral and soft tissue-related changes. A total of 47 1.5 T MRI examinations of knees (n = 21) and ankles (n = 26) of 42 haemophilic boys, age range, 22 months to 18 years, performed at different centres (Toronto, n = 20, Europe, n = 12 and Denver, n = 15) were independently reviewed by four radiologists at two occasions. Twenty-two examinations were from children 〈9 years and 25 from children ≥9. Sagittal and coronal gradient-echo (MPGR, 3D FLASH with fat saturation, GRASS) images were obtained. The MRI examinations of the ankle and knee studies presented with osteochondral abnormalities in 38.5% and 23.8% of the cases respectively. The two scoring systems demonstrated an excellent inter-reader [progressive, 0.88; additive (A, e, s and h components), 0.86] and intra-reader [progressive, 0.92; additive (A, e, s and h components), 0.93] reliability using intraclass correlation coefficients (ICCs). Although ICCs were slightly higher for knees when compared with ankles, and for older children when compared with younger children, all values fell within excellent inter- and intra-reader reliability categories. The two MRI scoring systems demonstrated a comparable reliability. This result constitutes the basis for further development of a combined MRI scoring system for assessment of haemophilic arthropathy, which incorporates progressive and additive components.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...