Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    facet.materialart.
    Unknown
    Pamplona : Periodicals Archive Online (PAO)
    Ius canonicum. 35:70 (1995) 673-728 
    ISSN: 0021-325X
    Topics: Law , Theology and Religious Studies
    Notes: OTROS ESTUDIOS
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1424
    Keywords: Water pore sizes ; Water channels ; Reflection coefficients ; Selectivity filters ; Proximal kidney tubule ; Single file transport
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Abstract Proximal straight tubules (PST) were dissected from rabbit kidneys, held by crimping pipettes in a chamber and bathed in a buffered isosmotic (295 mOsm/kg) solution containing 200 mm mannitol (MBS). Changes in tubule diameter were monitored on line with an inverted microscope, TV camera and image processor. The PST were then challenged for 20 sec with MBS made 35 mOsm/kg hyperosmotic by addition of either NaCl, KCl, mannitol (M), glycerol (G), ethylene glycol (E), glycine (g), urea (U), acetamide (A) or formamide (F). With NaCl, KCl, M, G, E, g, U, and A, tubules shrunk osmometrically within 0.5 sec and remained shrunk for as long as 20 sec without recovering their original volume (sometimes A showed some recovery). PST barely shrunk with F and quickly recovered their original volume. The permeability coefficients were 0 μm/sec (NaCl, M, g, E and U), 1 μm/sec (A), 84 μm/sec (F) and 0.02 μm/sec (G). The reflection coefficients σ = 1.0 (NaCl, KCl, M, G, E, g and U), 0.95 (A) and 0.62 (F). Similar σ values were obtained by substituting 200 mOsm/kg M in MBS by either NaCl, KCl, G, E, g, U, a or F. The olive oil/water partition coefficients are 5 (M), 15 (U), 85 (A) and 75 (F) (all x10−5). Thus, part of F permeates the cell membrane through the lipid bilayer. The probing molecules van der Waals diameters are 7.4×8.2×12.0 (M), 3.6×5.2×5.4 (U), 3.8×5.2 ×5.4 (A) and (3.4×4.5×5.4 (F) Å. We conclude that only F clearly permeates the water channel (WCH). Water molecules must single file within the WCH. After subtraction of the bilayer permeability of the probes, we estimate for the WCH selectivity filter cross-section a diameter of 4.2–4.7 Å (if it is circular) and 3.6×4.2 Å (if it is rectangular). But if the oxygens facing the WCH lumen H bond with the molecules crossing the WCH, the WCH selectivity filter would be 3.3–3.8 Å (circular) and 3.6×4.0 Å (rectangular).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' journal of analytical chemistry 365 (1999), S. 658-662 
    ISSN: 1432-1130
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract An atrazine flow-through fluoroimmunosensor was developed, based on an oriented antibody covalently bound to Protein-A (Prot-A) immobilized on Controlled Pore Glass (CPG). Atrazine was detected “in-situ” by placing the immobilized antibody in the optical path of the flow cell. Immobilization of 30 μg of polyclonal anti-atrazine antibody on 0.5 g of Prot-A-CPG provided the highest sensitivity. The effect of several solvents on the covalently immobilized antibodies regeneration was evaluated, the optimum conditions being achieved by pumping 5% acetonitrile (pH = 3) at 0.15 mL/min for 100 s. The detection limit of the immunosensor was 0.7 μg/L and the reproducibility was 2% and 4% for 5 μg/L and 40 μg/L, respectively, in the optimum working concentration range (0.7–50 μg/L). This device allowed 12 samples per hour to be analyzed and had a life-time of 200 assays. Simazine and desisopropylatrazine (DIA) were not cross-reactive, desethylatrazine (DEA) has a cross-reactivity of 8% and propazine and prometryn of 44% and 27%, respectively. The immunosensor was applied to the determination of atrazine in tap and ground water samples spiked at the ¶10 and 30 μg/L concentration level.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...