Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1433-0385
    Keywords: Key words: Ultrasonically activated scalpel ; Laparoscopic surgery ; Liver resection. ; Schlüsselwörter: Ultraschalldissektor ; Leberchirurgie ; laparoskopische Chirurgie.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung. Wir berichten über einen neuen, ursprünglich für die laparoskopische Chirurgie entwickelten Ultraschalldissektor. Die Gewebedurchtrennung wird durch einen Sägemechanismus der vibrierenden Hochfrequenzklinge bewirkt, die gleichzeitige Denaturierung der Proteine führt zu einer Coagulation eröffneter Blutgefäße bis zu einem Durchmesser von 2–3 mm. Der wesentliche Vorteil gegenüber der Elektrocoagulation oder der Verwendung eines Lasers besteht in der nur geringen Hitzeentwicklung im umgebenden Gewebe bei gleichzeitig gutem blutstillenden Effekt. Das Gerät eignet sich nicht nur hervorragend zur Präparation und Gewebedissektion in verschiedenen Bereichen der laparoskopischen Chirurgie, sondern auch zur Durchtrennung des Leberparenchyms im Rahmen der laparoskopischen und offenen Leberchirurgie.
    Notes: Summary. We report on our experience with a new ultrasonically activated scalpel that has been developed for laparoscopic surgery. It works by means of a longitudinally vibrating blade or scissors and can be used for tissue dissection, coagulation and preparation. The high-frequency vibration causes denaturation of protein and thus allows coagulation of small vessels up to 2–3 mm. The most important advantages compared to electrocautery are very limited heat generation, no production of smoke and the lack of current flow through the patient. Because of this, the ultrasonically activated scalpell is an excellent instrument for different types of laparoscopic surgery, as well as for open liver resection.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1433-0385
    Keywords: Key words: Incisional hernia ; Mesh repair ; Polypropylen ; Underlay technique. ; Schlüsselwörter: Narbenhernie ; Netzplastik ; Underlay-Verstärkungsplastik ; Polypropylennetz.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung. Problemstellung: Die Rezidivraten nach operativer Versorgung von Narbenhernien (NH) liegen für konventionelle Techniken (direkte Stoß-auf-Stoß-Naht, Fasciendoppelung nach Mayo) mit 30–50 % unakzeptabel hoch. Aus diesem Grund wird zunehmend der Einsatz von Verstärkungsplastiken mit diversen Kunststoffmaterialien propagiert. In Anlehnung an die herausragenden Ergebnisse französischer Hernienchirurgen versorgen wir seit 1996 im Rahmen einer prospektiven Studie alle komplizierten NH mit einem in Underlaytechnik implantierten Polypropylennetz. Methodik: Bruchsackpräparation und Abtragung erfolgen in üblicher Weise. Nach ausgedehnter intraabdomineller und subcutaner Mobilisation der Bauchdecke folgt die Präparation des hinteren Fascienblattes des M. rectus abdominis auf beiden Seiten bis in die lateralen Umschlagfalten. Nach fortlaufendem Verschluß von Peritoneum und hinterem Fascienblatt in der Medianen wird das Polypropylennetz spannungsfrei auf die hintere Rectusscheide aufgenäht und Muskulatur sowie vorderes Blatt der Fascienscheide fortlaufend verschlossen. Bei lateralen Hernien kann das Netz problemlos zwischen die einzelnen Muskelschichten eingebracht werden. Ergebnisse: Im Zeitraum vom 1. 1. 1996 bis 31. 8. 1997 wurden bei insgesamt 33 Patienten 14 primäre komplizierte NH und 19 Rezidiv-NH in dieser Technik versorgt. Lokale postoperative Komplikationen waren bei 4 Patienten (12 %) zu verzeichnen: 2 oberflächliche Wundheilungsstörungen, 1 revisionspflichtige Nachblutung sowie 1 durch Punktion erfolgreich behandeltes Hämatoserom. Ein Patient verstarb am dritten postoperativen Tag unter dem klinischen Bild einer fulminanten Lungenembolie (3 %). 22 Patienten, deren Operation mindestens 6 Monate zurückgelegen hatte, wurden im Mittel 9 Monate postoperativ (6–17) einer klinischen Nachuntersuchung unterzogen. Bisher wurden keine Rezidive beobachtet. Mit Ausnahme geringer, meist belastungsabhängiger ziehender Schmerzen (n = 6) und einem Gefühl der „straffen Bauchdecke“ (n = 3) wurden keine Beschwerden angegeben. Schlußfolgerung: Die dargestellte Technik der Underlay-Verstärkungsplastik mit Polypropylennetz berücksichtigt die Prinzipien der spannungsfreien anatomischen Bauchwandrekonstruktion und führt auch beim Risiko- und Rezidivpatienten zur Wiederherstellung einer stabilen Bauchdecke.
    Notes: Summary. Incisional hernia repair with conventional techniques (simple closure, Mayo-technique) is associated with unacceptable recurrence rates of 30–50 %. Therefore, surgical repair using different prosthetic biomaterials is becoming increasingly popular. Further to favourable results by French hernia surgeons, we studied the results of underlay prosthetic mesh repair using polypropylene mesh in complicated and recurrent incisional hernias. Method: After preparation and excision of the entire hernia sac, the posterior rectus sheath is freed from the muscle bellies on both sides. The peritoneum and posterior rectus sheaths are closed with a continuous looped polyglyconate suture. The prosthesis used for midline hernias is positioned on the posterior rectus sheath and extends far beyond the borders of the myoaponeurotic defect. The anterior rectus sheath is closed with a continuous suture. The prosthesis for lumbar and subcostal hernias is placed in a prepared space between the transverse and oblique muscles. Intraperitoneal placement of the mesh must be avoided. Results: Between January 1996 and August 1997 we performed a total of 33 incisional hernia repairs (14 primary hernias, 19 recurrent hernias) using this technique (16 women, 17 men, mean age 56.19 ± 12.92 years). Local complications occurred in four patients (12 %): superficial wound infection (n = 2), postoperative bleeding, requiring reoperation (n = 1), minor hemato-seroma (n = 1). One patient suddenly died on the 3rd post-operative day from severe pulmonary embolism (mortality 3 %). Twenty-two patients with a minimum follow up to 6 months were re-examined clinically. The average follow-up time for this group was 9 months (range 6–17 months). To date no recurrent hernias have been observed. There were only minor complaints like “a feeling of tension” in the abdominal wall (n = 3) and slight pain under physical stress (n = 6). Conclusions: The use of prosthetic mesh should be considered for repair of large or recurrent incisional hernias, especially in high-risk patients (obesity, obstructive lung disease) and complicated hernias. The aforementioned technique of underlay prosthetic repair using polypropylene mesh fixed onto the posterior rectus sheath allows for anatomical and consolidated reconstruction of the damaged abdominal wall with excellent results and low complication rates.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Der Orthopäde 27 (1998), S. 118-125 
    ISSN: 1433-0431
    Keywords: Key words Osteogenesis • Bone substitutes • Demineralized bone matrix • Hydroxyapatites ; Schlüsselwörter Knochenneubildung • Knochenersatzmaterialien • Demineralisierte Knochenmatrix • Hydroxylapatitkeramiken
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Probleme der autogenen wie allogenen Knochentransplantation bedingten u. a. eine intensive Suche nach geeigneten Ersatzmaterialien. Insbesondere bei der Heilung von knöchernen Defekten sollen durch Knochenersatzmaterialien den Knochentransplantaten ähnliche Ergebnisse erzielt werden; dies sowohl in bezug auf ihre biomechanische Belastbarkeit als auch – und dies im besonderen – auf Ihre biologischen Eigenschaften; d. h. die Fähigkeit zur Knochenneubildung, zur knöchernen Integration bis hin zum physiologischen Remodelling. In verschiedenen experimentellen Modellen an der Schafstibia wurden unterschiedliche Knochenersatzmaterialien wie Hydroxylapatitkeramiken aber auch biologische Ersatzmaterialien wie teildemineralisierte Knochenmatrix von uns untersucht und mit den Standardverfahren der autogenen wie allogenen Spongiosatransplantation verglichen. Hierzu verwendeten wir einerseits das Bohrlochmodell der Schafstibia als Kleindefektmodell mit 6-mm-Bohrdefekten und andererseits das Schaftdefektmodell der Schafstibia als Großdefektmodell mit 5 cm großen Kontinuitätsdefekten der Diaphyse. Die Auswertungen erfolgten anhand von Histologie, Mikroradiographie, Fluoreszenzmikroskopie sowie Morphometrie im Kleindefektmodell und Röntgenverlaufskontrollen im Großdefektversuch. Hydroxlapatitkeramiken zeigten hierbei nur eine geringe Eigenleistung bei der Knochenneubildung. Sie dienen lediglich im Sinne der Osteokonduktion als Leitschiene. Knochenmatrixpräparate hingegen zeigen eine rege Knochenbildung im Kleindefekt, stoßen jedoch im Großdefekt an die Grenze ihrer Leistungsfähigkeit. Unter Berücksichtigung ihres Wirkprinzips können durch diese aber auch große Defekte knöchern ausgeheilt werden.
    Notes: Summary Prompted by severe problems in autogeneic and allogeneic bone transplantation, intensive efforts were made to find sufficient substitutes. A main demand on these materials, especially in healing of osseous defects, is to achieve results comparable to those of auto- or allografts. These must be related to their biomechanical and particularly to their biological properties, i. e. the ability to form new bone, osseous integration and physiological remodeling. Within different trials in the tibiae of sheep we investigated bone substitutes like hydroxyapatite ceramics (HA) or partially demineralized bone matrix (pDBM) and compared them to the gold standards of autogeneic and allogeneic bone transplantation. Therefore we used two different models: the drill hole model with small size defects of 6 mm in diameter and the shaft defect model as a true-to-life defect with a 5 cm large diaphyseal defect. Evaluation was done by X-rays, histology, microradioraphy, fluorescent microscopy and morphometry of the small size defects. HA showed only small effects on new bone formation and works merely as an osteoconductor. However, excellent new bone formation was regularly achieved by pDBM in the small defects, whereas it was limited in the large size defects. But considering their mechanism of action, it is possible to bridge large bone defects by pDBM.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Surgical endoscopy and other interventional techniques 13 (1999), S. 306-307 
    ISSN: 1432-2218
    Keywords: Key words: Laparoscopic surgery — Complications — Optical trocar
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. The blind insertion of the Veress needle and the first trocar may cause serious complications. Therefore, many surgeons perform a minilaparotomy to safely position the first trocar. However, especially in obese patients, the dissection may be difficult and time consuming. As an alternative, optical trocars can be safely positioned under direct visualization. We report on our experience with the Optiview trocar in 200 patients and describe our preferred insertion technique. In our opinion, optical trocars are safe and easy to handle, offering several advantages over the use of the Veress needle and the minilaparotomy.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Surgical endoscopy and other interventional techniques 12 (1998), S. 907-910 
    ISSN: 1432-2218
    Keywords: Key words: Abdominal stab wounds — Laparoscopy — Penetrating trauma
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Background: Management strategies for abdominal stab wounds (ASW) in initially asymptomatic patients range from mandatory explorative laparotomy (EL) to conservative approaches with observation alone. Emergency diagnostic laparoscopy (DL) may play a potential role between these two extremes—hence lowering the rate of unnecessary laparotomies and keeping the rate of missed injuries to a minimum. Patients and Methods: At our institution mandatory EL was carried out in every patient with ASW until 1992. In a retrospective study the charts of 43 patients with ASW were reviewed in terms of initial diagnostic procedures, intraabdominal injuries, and course and length of hospital stay. Between 5/1993 and 4/1995 DL was performed in a prospective study in 15 patients with suspected peritoneal penetration (PP) after ASW according to a standardized diagnostic and therapeutic algorithm. Results: In 17 patients (40%) EL showed no PP; 15 (35%) had significant intraabdominal injuries, while 11 patients with PP didn't have lacerations of intraabdominal organs, resulting in an overall rate of nontherapeutic laparotomy of 65%. Mortality was 6% (n= 3), average hospital stay 8 days. Primary DL could exclude PP in 10 out of 15 patients (66%). The remaining five patients (33%) showed PP: In two patients with ASW to the right upper quadrant, intraabdominal injuries could be excluded by DL, and in one patient a low-grade liver injury was treated laparoscopically, thus avoiding laparotomy in a total of 87% (n= 13). In two patients with PP laparoscopy was converted to laparotomy: no pathological finding in one case, splenectomy for spleen laceration in the second patient, resulting in a rate of nontherapeutic laparotomies of 7%. All patients in this series had an uneventful course; average hospital stay was 2.4 days. Conclusions: DL offers an important diagnostic tool in excluding peritoneal penetration in ASW, hence lowering the rate of unnecessary laparotomies. Given experience and skills, laparoscopy may be used therapeutically in selected cases of ASW.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1436-0578
    Keywords: Schlüsselwörter Troponin T ; 12-Kanal-EKG ; Akutes Koronarsyndrom ; Präklinische Versorgung ; Notarzt ; Keywords Troponin T ; 12-lead ECG ; Acute coronary syndrome ; Prehospital treatment ; Emergency physician
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract In our study we tested 2 different rapid assays for cardiac troponin t (TropT®-rapid assay, diagnostic cut-off 0,2 ng/ml and TropTsensitive®-rapid assay, diagnostic cut-off 0,1 ng/ml) in 75 chest pain patients. Additional to the emergency ECG (3-lead) we acquired a 12-lead ECG. The TropT®-rapid assay showed a sensitivity of 11% (specifity 94,3%). The TropT sensitive®-rapid assay showed a sensitivity of 62% (specifity 100%). In patients with acute myocardial infarction 12-lead ECG showed a sensitivity of 82% (3-lead ECG 24%). An risk-orientated check-up for thrombolysis contraindications should be done to identify risk-patients. Further education of emergency physicians in 12-lead ECG should be done.
    Notes: Zusammenfassung In der vorgestellten Untersuchung wurden 2 Troponin-T-Schnelltests –, der TropT®-Test (Schwellenwert 0,2 ng/ml) und der TropT sensitive®-Test (Schwellenwert 0,1 ng/ml) – im präklinischen Einsatz bei 75 Patienten mit “akutem Koronarsyndrom” getestet. Zusätzlich wurde bei allen Patienten ein 12-Kanal-EKG abgeleitet. Der Troponin-T-Schnelltest zeigte in unserer Untersuchung eine Sensitivität von 11% bzw. 62%. Die Spezifität lag bei 94,3% bzw. 100%. Die Sensitivität des 12-Kanal-EKG lag bei 82%. Der Troponin-T-Schnelltest kann in einzelnen Fällen einen Benefit zeigen, kann jedoch nicht für den präklinischen Routineeinsatz empfohlen werden. Eine präklinische 12-Kanal-EKG-Ableitung lässt sich sicher und einfach durchführen und führt zu einer Reduktion der “door-to-needle-time”. Im “Fachkundenachweis Rettungsdienst” sollte vor diesem Hintergrund die differenzierte EKG-Auswertung akzentuiert werden.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Langenbeck's archives of surgery 380 (1995), S. 37-42 
    ISSN: 1435-2451
    Keywords: Thoraxchirurgie ; Komplikationen Mortalität ; FEV1 ; Präoperative Eigenbluttransfusion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Die Qualität perioperativer Maβnahmen bei thoraxchirurgischen Patienten ist im Hinblick auf Morbidität und Mortalität von gröβter Wichtigkeit. Aus diesem Grunde haben wir das eigene Vorgehen genauer untersucht. Über einen Zeitraum von 3 Jahren wurde das klinische Follow-up bei 792 Patienten (812 Thorakotomien in Folge) dokumentiert und analysiert. Die durchschnittliche Rate von Komplikationen betrug 19,7%, die Mortalität — über eine 30-Tage-Periode — 3,8%. Sekretostase, Atelektase und Pneumonie waren die häufigsten Komplikationen. Mittels Eigenblutkonserven konnte der Prozentsatz von Patienten, die Transfusionen von Fremdblut brauchten, von 27 auf 9% gesenkt werden. Eine Erhöhung der Komplikationsrate bzw. eine Verlängerung des stationären Aufenthalts war nicht festzustellen. Postoperative Wundinfektionen konnten durch perioperative antibiotische Prophylaxe signifikant verringert werden. Ähnlich signifikante Verringerungen der FEV1 nach thoraxchirurgischen Eingriffen wurden — unabhängig vom Ausmaβ des resezierten Lungengewebes — beobachtet; dies weist darauf hin, daβ das verbleibende Lungengewebe während der postoperativen Periode stark in Mitleidenschaft gezogen wird und daβ das chirurgische Trauma als solches mindestens 2 Wochen lang eine Hauptrolle für die postoperative Lungenfunktion spielt.
    Notes: Abstract The quality of perioperative treatment for patients undergoing thoracic surgery is of the utmost importance for postoperative morbidity and mortality. Hence, it was the purpose of this study to examine various aspects of our own procedure. The clinical course following 812 successive thoracotomies in 792 patients over a period of 3 years was documented and analysed. The overall complication rate was found to be 19.7%, with a mortality of 3.8% over a 30-day period. Secretostasis, atelectasis and pneumonia were the most common complications. Owing to the predeposition of autologous blood, the percentage of patients requiring allogeneic blood transfusion was reduced from 27% to 9%. There was no evidence suggesting an increase in the complication rate or a longer stay in hospital. Perioperative antibiotic prophylaxis has reduced postoperative wound infection significantly. Similar reductions in the FEV t are recorded following thoracic surgery, irrespective of the amount of lung tissue resected. This observation indicates that the remaining lung tissue is severely compromised throughout the postoperative period and that the surgical trauma alone is a major factor influencing postoperative pulmonary function for at least 2 weeks.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1433-0385
    Keywords: Keywords: Laparoscopic cholecystectomy – Bile duct complications – ENBD – Therapy – Prophylaxis. ; Schlüsselwörter: Laparoskopische Cholecystektomie – Gallengangkomplikationen – ENBS – Therapie – Prophylaxe.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung. Einleitung: Gallengangkomplikationen treten nach der laparoskopischen Cholecystektomie 2–3mal häufiger als nach dem offenen Vorgehen auf. Die Klassifikation von Siewert unterscheidet postoperative Gallefisteln (Typ I), Spätstrikturen (Typ II), tangentiale Gallengangverletzungen (Typ III) und Defektläsionen (Typ IV). Anhand der eigenen Erfahrungen sowie der aktuellen Literatur wird ein diagnostisches und therapeutisches Management vorgeschlagen. Methoden: Zwischen November 1993 und Dezember 1998 wurden 11 Patienten (medianes Alter 43,8 ± 17,2 Jahre) mit Gallengangkomplikationen nach laparoskopischer Cholecystektomie operativ versorgt. Neun Patienten (4 Typ-II-Läsionen, 5 Typ-IV-Läsionen) wurden von einem auswärtigen Krankenhaus übernommen, 2 Defektläsionen traten bei 410 laparoskopisch cholecystektomierten Patienten (0,5 %) im eigenen Kollektiv auf. Ergebnisse: Vier Patienten mit Spätstrikturen wurden nach 14,3 ± 8,4 Monaten durch die Anlage einer bilio-biliären (n = 2) bzw. biliodigestiven (n = 2) Anastomose behandelt, und nach 10,6 ± 3,8 Tagen beschwerdefrei nach Hause entlassen. In beiden Fällen mit Typ-IV-Läsion und kurzer Defektstrecke konnte eine End-zu-End-Anastomose erfolgen (stationärer Aufenthalt 11,6 ± 1,0 Tage), bei größerer Defektstrecke (n = 5) mußte eine retrokolische End-zu-Seit-Hepaticojejunostomie in Y-Roux-Technik angelegt werden (stationärer Aufenthalt 14,8 ± 2,0 Tage). Beide Defektläsionen aus dem eigenen Patientenkollektiv wurden durch intraoperative Cholangiographie erkannt und unmittelbar nach Konversion mit einer biliobiliären bzw. biliodigestiven Anastomose versorgt (stationärer Aufenthalt 11,2 ± 0,6 Tage). Schlußfolgerung: Durch anatomische Präparation, selektive intraoperative Cholangiographie und frühzeitige Konversion zur offenen Cholecystektomie kann die Incidenz von Gallengangkomplikationen bei laparoskopischer Cholecystektomie niedrig gehalten werden. Der klinische Verlauf nach Gallengangverletzung ist nur bei standardisiertem diagnostischen und operativen Vorgehen und bei rascher Überweisung in ein spezialisiertes Zentrum positiv beeinflußbar.
    Notes: Abstract. Introduction: Bile duct complications after laparoscopic cholecystectomy occur twice to three times more frequently than after an open procedure. Four different types of lesions may be differentiated by the Siewert classification: postoperative bile fistulas (type I), late strictures (type II), tangential injuries of the bile duct (type III) and defect lesions (type IV). The diagnostic and therapeutic management is demonstrated in relation to our own experience and the literature. Methods: Eleven patients (median age 43.8 ± 17.2) with bile duct complications after laparoscopic cholecystectomy were operatively treated between November 1993 and December 1998. Nine patients (four type-II lesions, five type-IV lesions) were referred from another hospital; 2 defect lesions out of 410 laparoscopic cholecystectomies (0.5 %) were documented in our own patient group. Results: Four patients with late strictures were operatively treated with a hepaticocholedochostomy (n = 2) or hepaticojejunostomy (n = 2) after 14.3 ± 8.4 months and were discharged from hospital after 10.6 ± 3.8 days. In both cases with type-IV lesion and a short defect, an end-to-end anastomosis was successful (hospital stay 11.6 ± 1.0 days). However, a retrocolic Roux-Y end-to-side hepaticojejunostomy was perfomed in all cases with a larger defect (n = 5; hospital stay 14.8 ± 2.0 days). The two defect lesions in our own group were detected by intraoperative cholangiography and immediately treated after conversion either with hepaticocholedocho-stomy or hepaticojejunostomy (hospital stay 11.2 ± 0.6 days). Conclusions: The incidence of bile duct complications after laparoscopic cholecystectomy might be kept down by anatomic preparation, selective intraoperative cholangiography and early consideration of conversion to open procedure. The clinical course after biliary tract injury can be positively influenced only by a standard diagnostic and operative procedure and by an early transfer to a specialized center.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...