Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Zeitschrift für angewandte Mathematik und Physik 1 (1950), S. 271-276 
    ISSN: 1420-9039
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mathematics , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    International archives of occupational and environmental health 64 (1992), S. 43-48 
    ISSN: 1432-1246
    Keywords: Chimney sweeps ; Occupational disease ; Cancer risk ; External exposure ; Polycyclic aromatic hydrocarbons
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Within the framework of a longitudinal study, 127 chimney sweeps from the area of Upper and Middle Franconia (Bavaria, Germany), who had participated in a first medical check-up in 1974, were offered follow-up examinations in 1990. Eighty-one subjects participated in these examinations; in addition individual occupational case histories and medical case histories were obtained for a further 15 and 35 chimney sweeps, respectively. Five test subjects had died before the evaluation deadline (August 15, 1990). The causes of death were a non-Hodgkin's lymphoma, a bladder carcinoma, pulmonary metastases with unknown primary tumour, a suicide and an acute myocardial infarction. Conspicuous results were carcinoma of the oesophagus in one case and leucoplakia of the mucous membranes in the mouth and pharyngeal region in three cases; furthermore one chimney sweep had two haemorrhagic lumps on his vocal cords. Taking into account important non-occupational hazards (alcohol and nicotine abuse) as possible causes of these changes and the lack of relevant occupational exposure to products of incineration over a number of years, none of these cases nor any of the other ascertained results could be considered likely to be causally related to occupational activities. Due to the small number of cases, an epidemiological risk evaluation did not seem useful. Comparison with the results of other chimney sweep studies published in the international literature is not helpful due to the differences in study design, the varying case frequencies, and the different conditions of exposure.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Zeitschrift für angewandte Mathematik und Physik 6 (1955), S. 341-344 
    ISSN: 1420-9039
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mathematics , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Zeitschrift für angewandte Mathematik und Physik 4 (1953), S. 163-166 
    ISSN: 1420-9039
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mathematics , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Archives of orthopaedic and trauma surgery 115 (1996), S. 33-37 
    ISSN: 1434-3916
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The stability of wire cerclage was investigated on a wooden model. Two semitubular shells made of hard oak were firmly joined together using cerclage wires of different diameters and with different techniques. A conical test piece was then implanted. The test set-up was subjected once to an axial force of 4 kN and a torque of 20 Nm using a testing machine. Implant excursion at the interface was measured. One hundred forty measurements carried out on test pieces with fissures demonstrated that cerclage wires with the largest diameter possible should be used with a double-loop technique. Wire diameters under 1.2 mm are unsuitable for cerclage of the femur because they rupture easily. The most stable cerclage is obtained with two double cerclages using 1.5-mm stainless steel wires. Although micromotion is greater than for the reference group without fissures, no cases of excursions exceeding 100 μm could be measured. In comparison with a femoral shaft that is not fractured, marked instability remains. It is recommended that a tightening tool be used to tighten the wires, as this achieves considerably more stable cerclage than that achieved with two forceps.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Helvetica Chimica Acta 27 (1944), S. 1495-1501 
    ISSN: 0018-019X
    Keywords: Chemistry ; Organic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Helvetica Chimica Acta 27 (1944), S. 1480-1495 
    ISSN: 0018-019X
    Keywords: Chemistry ; Organic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: 1. Beim Umsetzen von Magnesiumoxyd in Magnesiumchloridlösung konzentrierter als 1,25-m. bilden sich zwei wohldefinierte Hydroxychloride mit charakteristischem Röntgendiagramm. Zuerst bildet sich bei allen Konzentrationen die instabile Verbindung 1 MgCl2, 5 Mg(OH)2, 7 H2O; diese wandelt sich nachträglich in die bei allen Konzentrationen stabile Verbindung 1 MgCl2, 3 Mg(OH)2, 7 H2O um.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...