Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Blutersatz: Hämoglobin ; bovin ; Chirurgie: Leberresektion ; Hämodilution: Hydroxyäthylstärke ; Hämodynamik: pulmonal ; systemisch ; Sauerstofftransport ; Key words Blood substitute: haemoglobin ; bovine ; Haemodilution: hydroxyethyl starch ; Haemodynamics: pulmonary ; systemic ; oxygen transport ; Surgery: liver resection
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Haemoglobin solutions can be an alternative to allogeneic red-cell transfusions because they combine colloid osmotic with oxygen transport properties. Since severe toxic side effects have been overcome by ultrapurification, clinical interest has been focused on haemodynamics changes during application of haemoglobin preparations. The present clinical study examines changes of haemodynamic and oxygen transport parameters during and after haemodilution with ultrapurified polymerized bovine haemoglobin (HBOC-201) in comparison to hydroxyethyl starch (HES). Methods: After approval of the Ethics Committee, 12 patients (6 males and 6 females, mean age 59±10 years, ASA 1-2) undergoing elective liver resection were randomly allocated to receive either 3 ml·kg−1 6% HES 70000/0.5 (group 1) or 0.4 g· kg−1 HBOC-201 (group 2) within 30 min following autologous blood donation of 1 l and substitution with 2 l Ringer’s lactate. Measurements of blood gases, haemodynamics, and oxygen transport parameters were performed after induction of general anaesthesia, prior to and after blood donation, during and after infusion, at the beginning of surgery, and in the intensive care unit. Results: Demographic characteristics did not differ between groups. In contrast to the HES group, mean arterial pressure increased by 18% over baseline measurements in group 2. While pulmonary vascular resistance showed a trend to higher values in group 2, systemic vascular resistance increased to a maximum of 42% over baseline in group 2 and was twice as high as in the HES group. The cardiac index was lower in the HBOC-201 group than in the HES group. During and after HBOC-201 infusion, mixed-venous oxygen saturation and content and calculated oxygen delivery were lower in group 2 in comparison to group 1, while the oxygen extraction ratio was higher in group 2. Free haemoglobin reached a maximal concentration of 1.0±0.2 g·dl−1 30 min after the HBOC-201 infusion was started, but was not detectable in urine over time. The mean intravascular half-life of HBOC-201 was 8.5 h. Conclusions: Patients did not show any severe complications during and after infusion of HBOC-201. However, vasoconstrictive side effects resulted in increased systemic but not pulmonary resistance. Ongoing studies with higher doses of HBOC-201 applied in a larger number of patients will probably reveal potential clinical consequences of the demonstrated haemodynamic changes.
    Notes: Zusammenfassung Hämoglobinlösungen sind kolloidale Volumenersatzpräparate, die Sauerstoff transportieren und damit eine Alternative zur homologen Transfusion von Erythrozyten darstellen können. Ziel der vorliegenden klinischen Studie war es, ein polymerisiertes ultragereinigtes Rinderhämoglobin (HBOC-201) im Vergleich zu Hydroxyäthylstärke (HES) auf Veränderungen der Hämodynamik und der O2-Transportparameter während und nach Hämodilution zu untersuchen. Material und Methoden: Nach Zustimmung durch die Ethikkommission wurden 12 Patienten (6 m. u. 6 w., Alter 59±10 J., ASA I–II, die sich einer Leberteilresektion unterziehen mußten, randomisiert auf 2 Gruppen verteilt. In Gruppe 1 erhielten die Patienten im Anschluß an eine präoperative Eigenblutspende von 1 l eine Infusion von 3 ml·kg−1 6% HES 70000/0,5 über 30 min sowie 2 l Ringerlaktat. Patienten der Gruppe 2 erhielten 2 l Ringerlaktat und über 30 min 0,4 g·kg−1 HBOC-201. Blutgasanalysen, Hämodynamik und Parameter des O2-Transports wurden vor und nach Eigenblutspende, während und nach Infusion, bei Operationsbeginn und auf der Intensivstation gemessen. Ergebnisse: Der arterielle Mitteldruck stieg unter Infusion von HBOC-201 im Gegensatz zu HES um maximal 18% gegenüber der Ausgangsmessung an. Während der pulmonale Gefäßwiderstand in der HBOC-201-Gruppe einen Trend zu höheren Werten als in der HES-Gruppe zeigte, stieg der systemische Gefäßwiderstand unter Infusion von HBOC-201 im Vergleich zum Ausgangswert um maximal 42% und war doppelt so hoch wie in der HES-Gruppe. Der Cardiac-Index lag in der HBOC-201-Gruppe unter den Werten der HES-Gruppe. Gemischt-venöse O2-Konzentrationen und -Sättigung sowie das errechnete O2-Angebot waren während und nach HBOC-201 Applikation niedriger als in der HES-Gruppe, während die O2-Extraktion nach Infusion von HBOC-201 höher war als nach HES. Die maximale Plasmakonzentration von HBOC-201 betrug 1,0±0,2 g·dl−1, die intravasale Halbwertszeit im Mittel 8,5 h. Im Urin war kein freies Hämoglobin nachweisbar. Schlußfolgerung. Die Ergebnisse zeigen bei guter Verträglichkeit der HBOC-201-Lösung einen vasokonstriktorischen Nebeneffekt, der zu einer Steigerung insbesondere des systemischen Gefäßwiderstands führt.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Blutersatz: Bovines Hämoglobin ; Hydroxyäthylstärke ; Arterielle Stenose ; Oxygenierung: Gewebe ; Muskel ; Stenose ; Key words Blood substitute: hemoglobin ; bovine ; hydroxyethyl starch ; Oxygenation: tissue ; muscle ; stenosis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract We investigated the effects of ultrapurified polymerized bovine hemoglobin (HBOC-201) on skeletal muscle tissue oxygen tension when applied before establishment of a nearly complete arterial stenosis. Methods: Twelve foxhounds were anaes-thetized IV and mechanically ventilated with 30% oxygen in air. Catheters were inserted into the right femoral artery and vein for measurements of haemodynamic parameters and blood-gas sampling. Arterial blood flow of the left popliteal artery was measured by an electromagnetic flow probe. Skeletal muscle tissue oxygen tension (tpo2) was measured in the left gastrocnemic muscle using a stepwise-driven polarographic needle probe, creating histograms from 200 single tpO2 measurements. Following isovolaemic haemodilution with Ringer’s solution to a target haematocrit of 20%, the animals were randomly assigned to receive either 200 ml of predonated fresh blood (group 1) or 200 ml of HBOC-201 (MW 32000–500000; Hb 13±1 g·dl−1; group 2). After a 15-min stabili-zation period, a 95% artificial stenosis of the left popliteal artery was established. While animals of group 1 received two applications of 200 ml 6% hetastarch (HES, 200000; 0.5), animals of group 2 received 200 ml Ringer’s solution 45 and 75 min after establishment of the arterial stenosis, respectively. Variables were measured at baseline, after haemodilution and application of the respective compound, and 30, 60 and 90 min after establishment of the stenosis. Results: Demographic data, muscle temperature and arterial blood gases did not differ between groups. With the exception of a higher mean pulmonary artery pressure in HBOC-201-treated animals, haemodynamics did not differ between groups. In both groups oxygen delivery and oxygen consumption of the muscle decreased in parallel to the de- creasing blood flow during arterial stenosis. In contrast, oxygen extraction ratio increased after infusion of HBOC-201 and remained unchanged during stenosis (P〈0.05). In group 1, the tpO2 decreased during stenosis when compared to baseline (P〈0.001) and remained decreased after administration of HES. In contrast, administration of 200 ml of HBOC-201 before establishment of the arterial stenosis sustained the tpO2 values at nearly baseline levels during stenosis. Skeletal muscle tissue oxygen tension was higher after HBOC-201 infusion during stenosis when compared to HES infusion (P〈0.001). Conclusion: These data suggest that haemoglobin solutions can reach poststenotic tis-sues. The increased oxygen extraction after application of HBOC-201 is associated with improved skeletal muscle oxygen tension during severe arterial stenosis.
    Notes: Zusammenfassung Die Studie untersucht die Wirkung der ultra-gereinigten polymerisierten bovinen Hämoglobinlösung HBOC-201 auf den Sauerstoffpartialdruck des Skelettmuskels bei intravenöser Applikation vor Anlage einer 95%igen arteriellen Stenose. Methoden: Zwölf Foxhounds wurden intravenös anästhesiert und kontrolliert mit 30 Vol.-% Sauerstoff in Luft beatmet. In die rechte Femoralarterie und -vene wurden Katheter zur Messung hämodynamischer Parameter und zur Entnahme von Blutgasanalysen plaziert. Der Blutfluß der linken A. poplitea wurde mittels eines elektromagnetischen Flußmessers bestimmt. Der Gewebssauerstoffpartialdruck (tpO2) wurde im linken M. gastrocnemius mit einer polarographischen Meßsonde gemessen. Nach Hämodilution der Tiere mit Ringerlösung bis zu einem Hämatokrit von 20% wurden die Tiere randomisiert in zwei Gruppen zu je 6 eingeteilt. In Gruppe 1 wurde den Tieren 200 ml Hämodilutionsblut retransfundiert, während in der Gruppe 2200 ml HBOC-201 (MG 32000–500000, Hb 13±1 g·dl−1) infundiert wurden. Nach einer 15minütigen Ruhephase wurde eine 95%ige arterielle Stenose der linken A. poplitea angelegt. Den Tieren der Gruppe 1 wurde jeweils 45 und 75 min nach Anlage der Stenose je 200 ml 6% Hydroxyäthylstärke (HÄS, 200000; 0,5) infundiert, während den Tieren der Gruppe 2 je 200 ml Ringerlösung infundiert wurde. Messungen erfolgten nach Instrumentierung der Tiere, nach Hämodilution und Applikation von Blut oder HBOC-201 sowie jeweils 30, 60 und 90 min nach Anlage der Stenose. Ergebnisse: Muskeltemperatur, arterielle Blutgase und hämodynamische Parameter zeigten keine Gruppenunterschiede. Lediglich der mittlere Pulmonalarteriendruck lag nach HBOC-201 Infusion höher als in der Vergleichsgruppe. Der Sauerstofftransport zum Muskel und der Sauerstoffverbrauch sank in beiden Gruppen entsprechend der Reduktion des poststenotischen Blutflusses ab. Die Sauerstoffextraktionsrate des Muskels lag in Gruppe 2 nach HBOC-201 Infusion im Vergleich zur Gruppe 1 höher (p〈0,05). Der tpO2 sank im Skelettmuskel nach Anlage der Stenose in Gruppe 1 ab (p〈0,001) und zeigte keine Änderung nach Infusion von HÄS. In Gruppe 2 blieb der tpO2 auch nach Anlage der Stenose über den gesamten Untersuchungszeitraum unverändert. Schlußfolgerung: Die Ergebnisse dieser Untersuchung zeigen, daß die Applikation von HBOC-201 vor Anlage einer arteriellen Stenose einen Abfall des O2-Partialdrucks im poststenotischen Muskelgewebe verhindern kann.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...