Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 61 (1990), S. 2343-2348 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The construction and the fundamental studies of a repetitive flash x-ray generator having a simple diode with an energy-selective function are described. This generator consisted of the following components: a constant high-voltage power supply, a high-voltage pulser, a repetitive high-energy impulse switching system, a turbo molecular pump, and a flash x-ray tube. The circuit of this pulser employed a modified two-stage surge Marx generator with a capacity during main discharge of 425pF. The x-ray tube was of the demountable-diode type which was connected to the turbo molecular pump and consisted of the following major devices: a rod-shaped anode tip made of tungsten, a disk cathode made of graphite, an aluminum filter, and a tube body made of glass. Two condensers inside of the pulser were charged from 40 to 60 kV, and the output voltage was about 1.9 times the charging voltage. The peak tube voltage was primarily determined by the anode-cathode (A-C) space, and the peak tube current was less than 0.6 kA. The peak tube voltage slightly increased when the charging voltage was increased, but the amount of change rate was small. Thus, the maximum photon energy could be easily controlled by varying the A-C space. The pulse width ranged from 40 to 100 ns, and the x-ray intensity was less than 1.0 μC/kg at 0.3 m per pulse. The repetitive frequency was less than 50 Hz, and the effective focal spot size was determined by the diameter of the anode tip and ranged from 0.5 to 3.0 mm in diameter.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 62 (1991), S. 2115-2120 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The construction and the fundamental studies of a kilohertz-range flash x-ray generator having a triode in conjunction with an extremely hot cathode are described. This generator consisted of the following components: a constant-high voltage power supply, an energy storage condenser of 100 nF, a constant high-voltage power supply for regulating an initial grid voltage of −1.6 kV, a grid pulser, and an x-ray tube. The x-ray tube was of an enclosed-triode type and consisted of the following major parts: an anode rod made of copper, a plane anode tip (target) made of tungsten, a focusing electrode made of iron, a hot cathode (filament) made of tungsten, a grid made from tungsten wire, and a glass tube body. The energy storage condenser was charged from 50 to 70 kV, and the electric charges in the condenser were discharged repetitively to the x-ray tube by the grid electrode driven by the grid pulser. The temperature of the filament was about 2000 K, and the cathode current was primarily controlled by the grid voltage and its value was less than 1.2 A. The pulse widths were about 1 μs and the maximum repetitive frequency was about 2.0 kHz. The x-ray intensity was 19.7 nC/kg at 0.5 m per pulse with a peak grid voltage of 1.0 kV and a condenser charged voltage of 70 kV.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 57 (1986), S. 1399-1408 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The construction of a soft flash x-ray (FX) apparatus with a new type of FX tube for biomedical use is described. The FX apparatus may be used for condenser charging voltages of 50–90 kV and peak currents of 20–40 kA. The electric pulse width of the FX waveforms was almost constant and its value was about 0.3 μs. The effective focal spot varied according to the condenser charging voltage, the anode–cathode (A–C) distance, etc., ranging from 0.2–3.0 mm in diameter. We selected two combinations of electrodes: (a) for normal focusing and a high dose rate; (b) for fine focusing and a low dose rate. The FX intensity was determined by the condenser charging voltage and the A–C distance, while the FX quality (average spectrum distribution) was determined by the average voltage of the FX tube and insertion of metal filters. The average voltage of the FX tube varied according to the condenser charging voltage and the A–C gap impedance. Various clear FX images were obtained by controlling the FX intensity, quality, and the focal spot size. We used Fuji Computed Radiography (FCR) in conjunction with our FX radiography, and by controlling the FX quality and the focal spot size, we obtained some interesting biomedical radiograms.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0009-8981
    Keywords: Apolipoprotein A-I ; High-density lipoprotein ; Liver cirrhosis ; Proapo A-I converting enzyme ; Proapolipoprotein A-I
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Clinica Chimica Acta 191 (1990), S. 169-174 
    ISSN: 0009-8981
    Keywords: Carbonic anhydrase I ; Enzyme-linked immunoassay ; Erythroid cell
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Journal of Nuclear Materials 190 (1992), S. 174-187 
    ISSN: 0022-3115
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Energy, Environment Protection, Nuclear Power Engineering , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1432-2307
    Keywords: Cathepsin B ; Basement membrane ; Type IV collagen ; Metastasis ; Lung adenocarcinoma
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The distributions of cathepsin B (CB) a lysosomal cysteine proteinase, type IV collagen (CIV) and laminin (LM), which are main components of basement membranes (BMs) were studied in a series of 64 human lung adenocarcinomas using an immunohistochemical technique. Over-expression of CB (〉80% positive cells) was significantly associated with the grade of tumour differentiation (p〈0.01), with lymph node metastasis (p〈0.01) and with BM degradation (p〈0.01) detected by the staining pattern of CIV and LM. It was significantly associated with a prognostic disadvantage (p〈0.01). The immunohistochemical staining pattern of CB has a close relationship with degradation of BM, and may be used as a marker for tumour metastasis and prognosis in lung adenocarcinoma.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1573-6865
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract Immunohistochemical localization of the large proteoglycan, PG-M/versican, was studied in 36 breast tumours, including infiltrating ductal carcinomas, benign tumours and fibrocystic diseases. The relation between the proteoglycan and the other extracellular matrix components was also investigated. In the carcinoma tissues, the interstitial elements of the ‘specific stroma’, consisting of fibroblastic cells and fine fibrils, were reactive to antibody 2B1, which specifically recognizes the large proteoglycan, PG-M/versican. In the peripheral invasive areas of infiltrating ductal carcinoma, the most intense 2B1-positive reaction was visualized in mesenchymal tissues between carcinoma cell clumps and the surrounding tissues, where hyaluronic acid could be demonstrated histochemically. The 2B1-positive elements were not reactive to antibody 6B6, which specifically recognizes small proteoglycan. In the central sclerotic areas, where antibody 6B6 was reactive, a 2B1-positive reaction was detected only in elastosis masses, which also bound antibodies to type IV collagen and laminin, and to some extent antibody raised against chondroitin 6-sulphate proteoglycan. Elastic tissues of blood vessel walls and perivascular elements became reactive to antibody 2B1 when they were involved in carcinoma invasion. The present results have shown that PG-M/versican was localized in the proliferating interstitial tissues, in particular in hyaluronic acid-rich portions, in association with carcinoma cell growth, and also that PG-M/versican accumulated in vascular and perivascular elastic tissues involved in carcinoma invasion. The biological significance of PG-M/versican was briefly discussed
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...