    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: We describe a technique for producing a Maxwell–Boltzmann electron energy distribution using an electron beam ion trap (EBIT). The technique was implemented on the Lawrence Livermore EBIT to simulate Maxwellian plasmas. We discuss technical and experimental issues related to these simulations. To verify the fidelity of the quasi-Maxwellian, we have measured line emission due to dielectronic recombination (DR) and electron impact excitation (EIE) of heliumlike neon, magnesium, and argon for a range of simulated electron temperatures. The ratio of DR to EIE lines in heliumlike ions is a well understood electron temperature diagnostic. The spectroscopically inferred quasi-Maxwellian temperatures are in excellent agreement with the simulated temperatures. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 66 (1995), S. 67-71 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A technique has been developed to determine the absolute single particle counting efficiency of a channel electron multiplier (CEM) for positively charged ions at keV energies. The calibration technique is applicable to positive ion detectors in general. Ion beam currents of C2+ were created by charge transfer of C3+ on H2 in the thin target regime. By adjusting the H2 pressure in the beam scattering chamber from 10−10 to 10−6 Torr, C2+ currents could be created either low enough to be detected by the CEM in the particle counting mode or high enough to be measured as a current using the CEM as a Faraday cup. The CEM counting efficiency was determined by comparing the C2+ count rate to the C2+ current, scaling by the change in H2 pressure, and also scaling by the incident C3+ current for each C2+ measurement. This method, which effectively uses the charge transfer cross section as a "transfer standard,'' allows the CEM counting efficiency to be determined in situ and to be monitored accurately over extended periods of time. The calibration requires that only the relative, not the absolute, pressure change be known. The technique does not require the value of the charge transfer cross section to be known. The accuracy of the calibration technique for the present results was 10% at a confidence level considered to be equivalent to a statistical 90% confidence level. For the present work, the peak counting efficiency of a Galileo 4039 CEM for 32.5 keV C2+ ions was determined to be 96%. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1572-9540
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract An overview is given of the current spectroscopic effort on the Livermore electron beam ion trap facilities. The effort focuses on four aspects: spectral line position, line intensity, temporal evolution, and line shape. Examples of line position measurements include studies of the K-shell transitions in heliumlike Kr34+ and the 2s-2p intrashell transitions in lithiumlike Th87+ and U89+, which provide benchmark values for testing the theory of relativistic and quantum electrodynamical contributions in high-Z ions. Examples of line intensity measurements are provided by measurements of the electron-impact excitation and dielectronic recombination cross sections of the heliumlike transition-metal ions Ti20+ through Co25+. A discussion of radiative lifetime measurements of metastable levels in heliumlike ions is given to illustrate our time-resolved spectroscopy techniques in the microsecond range. We also present a measurement of the spectral lineshape that illustrates the very low ion temperatures that can be achieved in an EBIT.