Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 52 (1997), S. 495-500 
    ISSN: 1432-1041
    Keywords: Key words Nicotine ; vapour inhaler ; bioavailability
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract Objective: To investigate the temperature dependency of the dose released and the plasma levels of nicotine from a vapour inhaler. Methods: In an open, randomised, three-way cross-over pharmacokinetic study 18 healthy subjects inhaled nicotine for 20 min (80 inhalations) every hour for 10 h (11 administrations) at three different environmental temperatures: 20°, 30° and 40 °C. In the in vitroexperiment, 5, 10, 15 and 20 l air were forced through the inhaler. With a 15 l air volume, the average amount of nicotine released was 1.44, 3.49, 4.80 and 6.99 mg at 10 °C, 22 °C, 29 °C and 40 °C, respectively. The maximum dose released at the highest temperature (40 °C) and the largest air volume investigated (20 l) was approximately 7.5 mg. Results: In vivo peak plasma levels obtained at 30° and 40 °C were 29.7 and 34.0 ng · ml−1, compared with 22.5 ng · ml−1 at ambient room temperature (20 °C). At 20 °C, the area under the plasma concentration–time curve (AUC) of the last dosing interval was 20.5 ng · ml−1 · h. At 30 °C and 40 °C, the AUCs were 26.5 and 30.3 ng · ml−1 · h, respectively. The results thus showed a mean increase of the in vivo AUC by 29% at 30 °C and by 48% at 40 °C compared with the AUC at 20 °C. These increases should be compared to the in vitro results, showing a mean increase of 59% and 122%, respectively, at 30° and 40 °C. The in vitro results also showed that a relatively larger fraction of the dose was released into the first 5 l of air at the higher temperatures, at 40 °C, about 50% of the total amount released into 20 l. Conclusion: It was concluded that the in vitro/in vivo discrepancy was most probably due to increased aversive effects at elevated temperatures, causing the subjects to inhale smaller puff volumes. Further, the inhaler would not produce nicotine plasma levels exceeding those achieved following cigarette smoking, even in a hot climate.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 38 (1990), S. 189-193 
    ISSN: 1432-1041
    Keywords: estramustine phosphate ; prostatic cancer ; gastrointestinal absorption ; food intake ; calcium ; drug interaction ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The effect of milk and food on the pharmacokinetics of estramustine phosphate was investigated in six patients with prostatic cancer. In a randomized three-way cross-over study, the patients were given single doses of the drug together with low calcium water, low calcium food and milk. The evaluation was based upon the plasma concentration of two metabolites, estromustine and estrone, as parent drug could not be detected in plasma. The tmax and lag time of estromustine were significantly increased by milk and food intake and Cmax and AUC were significantly decreased. In comparison with water, the AUC of estromustine was 41% when the drug was taken with milk and 67% after simultaneous intake of standardized food. Corresponding figures for the peak values were 32 and 57%, respectively. The effect of milk and food intake on the pharmacokinetics of estrone was similar. Studies in vitro demonstrated that the dissolution of estramustine phosphate disodium was markedly impaired in the presence of calcium. It was concluded that the rate and extent of absorption of estramustine phosphate were decreased when the drug was taken with milk or food due to the formation of a poorly absorbable calcium complex. To obtain high and reproducible absorption of Estracyt®, the drug should not be taken together with milk, milk products or other calcium-rich food or drugs.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 26 (1984), S. 113-119 
    ISSN: 1432-1041
    Keywords: estramustine phosphate ; prostatic cancer ; pharmacokinetics ; metabolism ; estramustine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The pharmacokinetics of estramustine phosphate (EMP) was studied in five prostatic cancer patients given single i.v. and oral doses of EMP in a cross-over study. Plasma and urinary concentrations of parent drug, estramustine, estromustine (the estrone analogue), estradiol and estrone were followed for 32 h. The elimination of intravenous EMP from plasma was biphasic. The mean volumes of distribution were small, being 43 and 108 ml/kg for the central and peripheral compartments, respectively. The plasma clearance was 64 ml/kg/h, and the half-lives of the two phases were 0.16 and 1.27 h. Metabolism was the major route of elimination of EMP. It was readily dephosphorylated and oxidized to yield the cytotoxic metabolites estramustine and estromustine. Estromustine was the main metabolite in plasma. When given orally EMP underwent extensive presystemic dephosphorylation, which started in the gastrointestinal tract. The relative bioavailability of estromustine after administration of EMP-capsules was 44%, which reflects incomplete absorption of EMP rather than first-pass metabolism of estromustine. The terminal half-life of estromustine was 10–20 h, which suggests that EMP might be given once or twice a day.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...