Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. ; Stafa-Zurich, Switzerland
    Materials science forum Vol. 163-165 (May 1994), p. 115-132 
    ISSN: 1662-9752
    Source: Scientific.Net: Materials Science & Technology / Trans Tech Publications Archiv 1984-2008
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    FEBS Letters 75 (1977), S. 169-172 
    ISSN: 0014-5793
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    British journal of dermatology 92 (1975), S. 0 
    ISSN: 1365-2133
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Twenty-five patients with clinically proven, patch test positive nickel dermatitis were studied with the lymphocyte transformation test (LTT). Serial dilutions of NiSO4 were present in the lymphocyte culture. None of the controls showed lymphocyte blast transformation. In fourteen patients maximal incorporation of thymidine occurred at the highest dilutions (1:50,000–1:100,000). In eleven patients the highest incorporation occurred at the lower dilutions. The nature of the antigen responsible for the specific reaction remains unknown.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-2323
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. The objective of this study was to identify risk factors for the development of complications and unsatisfactory skin closure following fasciotomy for trauma. Risk factors included in the study are prolonged time from injury to fasciotomy, type of fasciotomy, site of injury, and kind of underlying injury. The study was a retrospective analysis of 100 consecutive fasciotomies done for trauma over a period of 38 months (December 1991 to January 1995) in a “level I” trauma center at a university-affiliated county teaching hospital. Ninety-four patients were eligible for analysis, 29 of whom (31%) developed complications at the fasciotomy site. The risk was increased for lower extremity versus upper extremity (34.3% versus 20.8%), prophylactic versus therapeutic (42.0% versus 24.6%), late (〉8 hours) versus early (37% versus 25%), and vascular versus musculoskeletal (38.8% versus 22.2%) trauma cases. The same risk factors negatively influenced the ability to close the skin primarily. The four subgroups defined by vascular/nonvascular injury and upper/lower extremity site had significantly different nonclosure rates ( p = 0.043). The rate was highest among the vascular/lower extremity group (60.5%) and lowest among the nonvascular/upper extremity group (15.4%). We concluded that fasciotomies in lower extremities, the presence of underlying vascular injuries, fasciotomies performed prophylactically, and a time between the injury and fasciotomy of more than 8 hours are associated with an increased risk for local complications. The same factors are associated with an increased need for skin grafting the wound.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-2323
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. The objective of this study was to assess the role of clinical examination, angiography, color flow Doppler imaging, and other diagnostic tests in identifying injuries to the vascular or aerodigestive structures in patients with penetrating injuries to the neck. A prospective study was made of patients with penetrating neck injuries. All patients had a careful physical examination according to a written protocol. Stable patients underwent routine four-vessel angiography and color flow Doppler imaging. Esophagography and endoscopy were performed for proximity injuries. The sensitivity, specificity, and predictive values of physical examination, color flow Doppler studies, and other diagnostic tests were assessed during the evaluation of vascular and aerodigestive tract structures in the neck. Altogether 223 patients were entered in the study. After physical examination 176 patients underwent angiography and 99 of them underwent color flow Doppler imaging. Angiographic abnormalities were seen in 34 patients for an incidence of 19.3%, but only 14 (8.0%) required treatment. Color flow Doppler imaging was performed on 99 patients with a sensitivity of 91.7%, specificity 100%, positive predictive value (PPV) 100%, and negative predictive value (NPV) 99%. These values were all 100% when only injuries requiring treatment were considered. None of the 160 patients without clinical signs of vascular injury had serious vascular trauma requiring treatment (NPV 100%), although angiography in 127 showed 11 vascular lesions not requiring treatment. “Hard” signs on clinical examination (large expanding hematomas, severe active bleeding, shock not responding to fluids, diminished radial pulse, bruit) reliably predicted major vascular trauma requiring treatment. Among 34 of the 223 total patients (15.2%) admitted with “soft” signs, 8 had angiographically detected injuries, but only one required treatment. An esophagogram was performed on 98 patients because of proximity injuries (49 patients) or suspicious clinical signs (49 patients), and two of them showed esophageal perforations. None of the 167 patients without clinical signs of esophageal trauma had an esophageal injury requiring treatment. It was concluded that physical examination is reliable for identifying those patients with penetrating injuries of the neck who require vascular or esophageal diagnostic studies. Color flow Doppler imaging is a dependable alternative to angiography. An algorithm for the initial assessment of neck injuries is suggested.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Organonitrogen pesticides ; Organophosphorus pesticides ; Apples ; Solvent extraction
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A gas chromatographic method employing a capillary column and a selective nitrogen/phosphorus detector (NPD) has been developed for the determination of organophosphorus (OP) and organonitrogen (NP) pesticides in horticultural samples (apples). The separation of sixteen pesticides and the internal standard was performed in thirteen minutes. The analytical characteristics of the method, including linear response ranges, detection limits, and reproducibility, have been studied using a 1∶1 mixture of ethyl acetate and xylene as extraction solvent. The possibility of mutual interference between pesticides has also been studied. A procedure for the quantitative extraction of the sixteen pesticides from apple samples has also been developed; for fifteen of the pesticides recoveries 〉85% were obtained after 90 minutes extraction. The effect of different solvents both on recovery and on the sensitivity of the subsequent chromatography were also investigated. It was found that the sensitivity required must be considered when the solvent for sample treatment is selected.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    s.l. ; Stafa-Zurich, Switzerland
    Materials science forum Vol. 500-501 (Nov. 2005), p. 429-436 
    ISSN: 1662-9752
    Source: Scientific.Net: Materials Science & Technology / Trans Tech Publications Archiv 1984-2008
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: The present work describes the correlation between the microstructure and themechanical properties of multiphase steels processed through a Continuous Annealing Process Line (CAPL). The mechanical and microstructural properties of one of the former experimental steel compositions was also processed via Batch Annealing (BA) and the results have been included for comparison reasons
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 355 (1996), S. 733-735 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract A hyphenated technique for coupling a spectrophotometric detector to a gas chromatograph with a packed column is described. The packed column was connected directly to the flow cell (path length 1 cm) which was placed in a UV-visible molecular absorption spectrophotometer with diode array detector. This detection system was employed for separating and determining benzene, toluene, 1,4-xylene, 1,2-xylene and mesitylene. Molecular absorption spectra of all the separated compounds have also been obtained. A new possibility for coupling capillary gas chromatography and gas phase molecular absorption spectrometry is currently being tested. In this new case, two fibre optics are used and the measurement is performed in the capillary column.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...