    Electronic Resource
    Springer
    European journal of nuclear medicine 11 (1985), S. 194-197 
    ISSN: 1619-7089
    Keywords: Thyroid scintigraphy ; Computer-assisted scintigraphy ; Rectilinear scanning ; Image modulation ; Count density
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We compared rectilinear scanning, analogous gamma-camera imaging and imaging using a gamma camera interfaced to a computer in order to determine which of these techniques is superior for thyroid scintigraphy. Forty patients with and without goitre and irregular activity distribution were imaged using each of the three techniques. The sets of three scintigrams per patient were rated by seven physicians. These ratings were statistically analysed using a new distribution-free test. Thyroid scintigraphy using a gamma camera interfaced to a computer turned out to be the best method, especially for detecting circumscribed areas of increased uptake. We conclude that this was due to a combination of the following factors: a computer matrix of 128x128 pixels in combination with an acquisition zoom of 1.5, the high count density of the scintigrams, computer-controlled documentation after data acquisition and the use of a continuous grey scale for documentation. The improved quality and information content of the scintigrams obtained using a gamma-camera/computer system could improve the diagnostic value of thyroid scintigraphy, especially when the scintigrams are also evaluated quantitatively.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of nuclear medicine 13 (1987), S. 100-102 
    ISSN: 1619-7089
    Keywords: Emission tomography ; Iterative reconstruction ; Thyroid
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract First SPECT results using a multiplicative iterative reconstruction algorithm are presented. The superiority of the iterative technique over filtered backprojection is demonstrated in two thyroid SPECT studies. Obvious benefits of the new reconstruction technique are better defined outlines of the imaged organ and patient body as well as negligible artificial image amplitudes outside the patient.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    European journal of nuclear medicine 8 (1983), S. 463-466 
    ISSN: 1619-7089
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The quality of three different labeling methods of visualizing the cardiac blood pool was investigated in 72 patients:99mtechnetium labeling of red blood cells in vivo or in vitro and human serum albumin. By the simplified technique of in vitro labeling of RBC from the view point of (1) labeling efficiency, (2) activity in the blood, (3) count rates in a standard ROI over the left ventricle and the paracardiac background, (4) ratio of these count rates, and (5) evaluation of image quality, the best results were obtained. HSA and in vivo labeled RBC led to satisfactory results for visual assessment of ventricular performance in most cases. In spite of the slightly higher technical investment involved in the in vitro labeling method this technique appears to be preferable for gated cardiac blood pool studies in view of the excellent labeling quality.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...