    European journal of nuclear medicine 11 (1985), S. 194-197 
    ISSN: 1619-7089
    Keywords: Thyroid scintigraphy ; Computer-assisted scintigraphy ; Rectilinear scanning ; Image modulation ; Count density
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We compared rectilinear scanning, analogous gamma-camera imaging and imaging using a gamma camera interfaced to a computer in order to determine which of these techniques is superior for thyroid scintigraphy. Forty patients with and without goitre and irregular activity distribution were imaged using each of the three techniques. The sets of three scintigrams per patient were rated by seven physicians. These ratings were statistically analysed using a new distribution-free test. Thyroid scintigraphy using a gamma camera interfaced to a computer turned out to be the best method, especially for detecting circumscribed areas of increased uptake. We conclude that this was due to a combination of the following factors: a computer matrix of 128x128 pixels in combination with an acquisition zoom of 1.5, the high count density of the scintigrams, computer-controlled documentation after data acquisition and the use of a continuous grey scale for documentation. The improved quality and information content of the scintigrams obtained using a gamma-camera/computer system could improve the diagnostic value of thyroid scintigraphy, especially when the scintigrams are also evaluated quantitatively.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of nuclear medicine 13 (1987), S. 100-102 
    ISSN: 1619-7089
    Keywords: Emission tomography ; Iterative reconstruction ; Thyroid
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract First SPECT results using a multiplicative iterative reconstruction algorithm are presented. The superiority of the iterative technique over filtered backprojection is demonstrated in two thyroid SPECT studies. Obvious benefits of the new reconstruction technique are better defined outlines of the imaged organ and patient body as well as negligible artificial image amplitudes outside the patient.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    European journal of nuclear medicine 20 (1993), S. 410-414 
    ISSN: 1619-7089
    Keywords: Autonomous volume ; Technetium-99m uptake ; Euthyroid and hyperthyroid goitre
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The aim of this work was to determine the autonomously functioning volume in euthyroid and hyperthyroid goitres for prognostic and therapeutic purposes. To this end, various groups of patients were selected: individuals without evidence of thyroid disease, euthyroid patients with diffuse goitre of normal structure and function, euthyroid patients with evidence of autonomy and patients with hyperthyroidism due to autonomy. In all of them the thyroid uptake of technetium-99m was determined under exogenous suppression (TcUs) in the euthyroid state and under endogenous suppression (TcU) in the hyperthyroid state. It was demonstrated that: 1. In patients with unifocal autonomy the TcUs and TcU correlated linearly with the autonomous volume delineated and measured by sonography. 2. A nearly identical result was obtained if the mean autonomous volume in individuals without thyroid disease of 2.2 ± 1.1 ml calculated by TcUs/TcU x total thyroid volume was used as a basis. 3. The critical autonomous volume, i.e. the volume at which hyperthyroidism will occur, was found to be 16 ml at a cumulated sensitivity and specificity of 〉0.9. The method can be used to select patients for definitive treatment before hyperthyroidism occurs and to measure the autonomously functioning volume independent of its distribution within the thyroid for treatment with radioiodine. The method is easy to perform and is also an example of how a relative parameter of a function can be converted into an absolute parameter of a functioning volume.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability