Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1440
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary The fluorimetric determination of serum cortisol was improved 1. using a pumpdevice to fill a special microcuvette avoiding the development of small bubbles, 2. using a recording spectrofluorometer with optimal absorption (464 nm) and emission (522 nm), and 3. allowing for maximal fluorescence of cortisol (80 min). Sensitivity (〈1 µg cortisol/100 ml), accuracy, precision and specificity of the method are reported. Normal values of 9.00 a.m. serum cortisol (9.7–32.0 µg/100 ml) and of values before and after ACTH infusion tests were determined. For adrenal insufficiency (Addisons disease, total adrenalectomy, or after hypophysectomy) the 9.00 a.m. values of serum cortisol were generally satisfactory for diagnosis. In partial adrenal insufficiency ACTH infusion tests had to be performed. Very low levels of serum cortisol (2–4 µg/100 ml) were obtained, when patients with adrenal insufficiency were substituted with dexamethasone for three days, proving the specificity of the method. Determination of circadian rhythms of serum cortisol in patients with adrenal insufficiency on cortisol substitutive therapy in divided doses demonstrated cortisol levels far below the normal values during the carly morning hours. This situation should be improved by dividing the cortisol dose as follows: 6 a.m.: 10 mg, 10 a.m.: 5 mg, 2 p.m.: 5 mg and 8 p.m. or later: 10 mg cortisol.
    Notes: Zusammenfassung Die fluorimetrische Methode zur Bestimmung von Serumcortisol wurde durch blasenfreie Füllung einer Spezialküvette mittels Pumpvorrichtung, durch Benützung eines Spectralfluorimeters, sowie Verlegung des Meßzeitpunktes (80 min) und durch optimale Anregung (464 nm) und Emissionsmessung (522 nm) verbessert. Empfindlichkeit (〈1 µg Cortisol/100 ml), Richtigkeit, Genauigkeit, Reproduzierbarkeit von Tag zu Tag (VK=6–7%) und Störfaktoren der Methode werden angegeben. Mit dieser Methode wurden Normalberciche für die 9 Uhr-Nüchterncortisolwerte und die i.v. ACTH-Belastung ermittelt. Bei NNR-insuffizienten Patienten (M. Addison; Zustand nach Operation eines Hypophysentumors; total Adrenalektomierte) wurden i.v. ACTH-Belastungen durchgeführt, wobei sich bereits beim 9 Uhr-Nüchterncortisolwert eine diagnostisch gut brauchbare Trennung gegenüber dem Normalbereich ergab. Unter Dexamethasonsubstitution wurden bei NNR-Insuffizienz sehr niedrige Cortisolspiegel gemessen, was für die Spezifität der Methode spricht. Dic Bestimmung des 24 Std-Rhythmus der Cortisolwerte bei NNR-Insuffizienten zeigte, daß besonders in den frühen Morgenstunden im Vergleich zu Normalpersonen erniedrigte Cortisolspiegel bestehen. Daraus wird ein besserer Verteilungsvorschlag für die Cortisol-substitution abgeleitet.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Journal of molecular medicine 53 (1975), S. 385-389 
    ISSN: 1432-1440
    Keywords: Coronary heart disease ; myocardial infarction ; risk factors ; erythrocyte aggregation ; cell volume distribution ; Koronare Herzkrankheit ; Herzinfarkt ; Risikofaktoren ; Erythrocytenaggregation ; Erythrocytenvolumenverteilung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung 1. Die in-vitro-Messung der Erythrocytenaggregation wurde so verbessert, daß der Variationskoeffizient auf ±14,2% herabgedrückt wurde. 2. Mit der verbesserten Methode konnten die früheren Befunde statistisch hochsignifikant gesichert werden, daß sonst gesunde starke Raucher einen wesentlichen höheren Erythrocytenaggregationswert aufweisen als Nichtraucher. 3. Es wurde auch bei anderen Risikofaktoren koronarer Herzerkrankungen nachgewiesen, daß sie zu einer Erhöhung des Aggregationswerts der Erythrocyten führen. Insbesondere konnte dies bei Hypercholesterinämie nachgewiesen werden. 4. Mehrere Risikofaktoren beim gleichen Patienten bewirken einen überadditiv hohen Aggregationswert der Erythrocyten.
    Notes: Summary 1. The vitro test for red blood cell aggregation has been improved, the coefficient of variation was decreased to 14.2. 2. By the improved method the earlier findings were confirmed with high statistical significance that heavy smokers have a significantly higher red blood cell aggregation value in comparison with nonsmokers. 3. It could be shown that other coronary risk factors, especially hypercholesterolaemia, increase the aggregation value too. 4. The aggregation of red blood cells increases in the presence of several coronary risk factors in the same patient to higher values than expected from the addition of the aggregations caused by single risk factors.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Annals of hematology 42 (1981), S. 53-55 
    ISSN: 1432-0584
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-1904
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Natural Sciences in General
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 252 (1970), S. 284-287 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Durch täglich frische Zubereitung eines stabilen Fluorescenzreagenses, durch Fluorimetrie 80 min nach Zugabe des Fluorescenzreagenses zum dichlormethanextrahierten Cortisol, durch streng blasenfreie Füllung einer Spezialmikroküvette mittels Pumpvorrichtung und durch optimale Messung der Cortisolfluorescenz im registrierenden Spektralfluorimeter bei 464 nm (Anregung) und 522 nm (Emission) wurde die fluorimetrische Serumcortisolbestimmung verbessert. Die Methode erlaubt eine Serumcortisolbestimmung mit hoher Empfindlichkeit (〈 1 μg/100 ml), Präzision an einem Tag (Variationskoeffizient = 4,7% für 10 μg/ 100 ml) und Präzision von Tag zu Tag (VK=6–7%, Kontrollserum). Für die Spezifität der Methode sprechen die niedrigen Serumcortisolwerte von Adrenalektomierten unter Dexamethasonsubstitution (〈 2 μg/100 ml). Die klinische Brauchbarkeit der Methode für diagnostische und therapeutische Fragen wird diskutiert.
    Notes: Abstract The fluorometric determination of cortisol in serum was improved by the following measures: 1. Daily preparation of the fluorescence reagent (ethanol abs.: conc. H2SO4= 3∶7, v/v) at 0°C. 2. Fluorometry 80 min after the addition of the fluorescence reagent to dichloromethane extracted cortisol. 3. Filling of a special micro-cuvette by a pump system avoiding bubble formation in the cuvette. 4. Spectrofluorometer with optimal absorption (464 nm) and emission (522 nm) for cortisol. The method is of satisfactory sensitivity for cortisol (〈 1 μg/100 ml), precision (10 μg/100 ml ∶ S.D. = 0.5 μg/ 100 ml) and reproducibility from day to day (variation coefficient = 6–7%). The specificity of the method is demonstrated by the low values (〈 2 μg/100 ml) of total-adrenalectomized patients under dexamethasone maintainance (2 × 0.25 mg/day). The normal range (mean ± 2 S.D., logarithmic distribution) of 900 a.m. serum cortisol values of control persons is 9.7–32.0 μg/100 ml. Examples of the application of the method for diagnostic and therapeutic questions are reported.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...